● The following states are judged to be indeterminate states and displayed as "
".
• Full light entry state
• State in which more than one edge is detected (such as detection of transparent body)
If auto edge detection mode is set, the base position will be switched according to the direction
(TOP or BOTTOM side) in which the measured object enters the measurement area of the
sensor head, causing the HIGH and LOW set values to be switched.
■
Example of switching between HIGH and LOW set values
When the measured object enters the measurement area from the TOP side
When the measured object enters the measurement area from the BOTTOM side
● When the measured object enters the measurement area from the TOP side, LOW set value
2.0 mm is used. When the measured object enters the measurement area from the BOTTOM
side, LOW set value 2.0 mm is switched to HIGH set value 8.5 mm.
● When the measured object enters the measurement area from the BOTTOM side, HIGH set
value 7.0 mm is used. When the measured object enters the measurement area from the
TOP side, HIGH set value 7.0 mm is switched to LOW set value 3.5 mm.
● If auto edge detection mode is set, the upper limit for measured values is 10.5 mm.
5.4.2 Edge Detection Mode (
)
When the direction in which the measured object enters the measurement area of the sensor
head is specified as the TOP or BOTTOM side, this mode measures the distance from the TOP
or BOTTOM side of the measurement area to the edge of the measured object.
5.4 Operation Mode
WUME-HGT-6
5-23
Содержание HG-T Series
Страница 2: ... MEMO 2 WUME HGT 6 ...
Страница 28: ... MEMO 2 8 WUME HGT 6 ...
Страница 96: ... MEMO 5 50 WUME HGT 6 ...
Страница 99: ... Note 2 Displayed only during calculation 6 1 Flow of Measurement Data WUME HGT 6 6 3 ...
Страница 128: ... MEMO 6 32 WUME HGT 6 ...
Страница 158: ... No timer OFF 7 2 Advanced Settings 7 30 WUME HGT 6 ...
Страница 177: ...Example Positioning a glass plate Setting method 7 2 Advanced Settings WUME HGT 6 7 49 ...
Страница 218: ...8 2 3 Side View Attachment HG TSV10 Units mm 8 2 Dimension Drawings 8 14 WUME HGT 6 ...
Страница 221: ...10 Troubleshooting 10 1 Troubleshooting 10 2 10 2 Error Messages 10 5 WUME HGT 6 10 1 ...
Страница 228: ...Menu Structure General Function Display Menu Structure General Function Display App 2 WUME HGT 6 ...
Страница 229: ...Menu Structure General Function Display WUME HGT 6 App 3 ...
Страница 230: ...Menu Structure Extended Function Display Menu Structure Extended Function Display App 4 WUME HGT 6 ...
Страница 231: ...Menu Structure Extended Function Display WUME HGT 6 App 5 ...
Страница 232: ... MEMO App 6 WUME HGT 6 ...
Страница 235: ... MEMO WUME HGT 6 ...
Страница 236: ...Panasonic Industrial Devices SUNX Co Ltd 2020 PRINTED IN JAPAN WUME HGT 6 ...