Panasonic HF Series Скачать руководство пользователя страница 5

Matters to Be Observed When Using This Product

An abnormal state for varistors (ZNR surge absorbers) of the D type/V series and SMD-Type/HF, VF Series (hereinafter 

the product or "the surge absorber") that results from a problem with service conditions (materials used, the surrounding 

environment, power conditions, circuit conditions, etc.) may cause a fire accident, electric shock accident, burn accident, 

or product failure. Matters to note when handling this product will hereinafter be described. What is described below should 

be checked sufficiently before the product is used.

 Confirming rated capabilities

Use the surge absorber within the range of its rated capabilities. Each type of surge absorber has specified rated 

capabilities including a maximum allowable circuit voltage, a surge current tolerance, an energy tolerance, an impulse 

lifespan (surge lifespan), average pulse power, and a service temperature. Using the surge absorber under severe 

service conditions that are beyond the rated capabilities causes degraded performance of the surge absorber or 

destruction of a circuit element, which may lead to smoke generation, ignition, etc.

 Take the following measures in order to avoid an accident caused by expected phenomenon.

(1) Destruction of the surge absorber may scatter its fractured pieces around. To protect other elements from these

pieces, set product in a case or shield it with a cover.

(2) Do not place the surge absorber near combustible materials (vinyl cable, resin mold, etc.). If avoiding the vicinity

of combustible materials is difficult, protect the combustible material with an incombustible cover.

(3) Surge absorber placed between lines

When the surge absorber is placed between lines, connect a normal type current fuse in series with the surge 

absorber.

* See "Current fuse" in the "Circuit design and circuit board design" section.

(4) Surge absorber placed between a line and the ground

 When the surge absorber is placed between a line and the ground, even if the surge absorber short-circuits,

ground resistance will remain in the section between the line and the ground, leaving a possibility that the 

current fuse won’t blow, in which case the outer sheath resin of the surge absorber may generate smoke or 

ignite due to current flow. To prevent such a case, place an earth leakage breaker in a location closer to the 

power supply than the surge absorber. When not using an earth leakage breaker, use a current fuse and 

temperature fuse in series with each other.

* See Table 1 in the "Circuit design and circuit board design" section.

 When the surge absorber is placed between a live part and a metal case, it may cause electric shock if the

surge absorber short-circuits. To avoid this, ground the metal case or shield it to prevent direct contact with the 

metal case. 

 In case the surge absorber should short-circuit and generate smoke or ignite, immediately cut off current flow

to the surge absorber.

 Rated voltage for UL certification, etc.

To allow the surge absorber to meet leak current requirements, etc., a maximum allowable circuit voltage and rated 

voltage are specified for the surge absorber.

When applying for UL certification, etc. of a device equipped with a surge absorber, ensure the working voltage of the 

device does not exceed the rated voltage of the surge absorber.

 An unexpected sharp rise in the working voltage, an incoming excessive surge, etc., may cause the surge absorber to

generate smoke or ignite.

In such a case, fire spreading through the device should be prevented to avoid expanded damage. To achieve this, 

take a multi-protection measure, such as adopting fire-resistant materials that make up the outer shell components 

and structural materials.

30-Jun-23

 

Safety measures

Matters to Be Observed When Using This Product

(D-type : V series / SMD-type : HF

VF series)

Содержание HF Series

Страница 1: ...se regarding this product please be sure to contact us immediately 20 Jan 23 E Part No ERZHF2M220F Sn plated Cu alloy ERZHF2M220D ERZHF2M270 Sn plated Ni Fe alloy 6 4 0 4 8 0 0 5 5 5 0 5 1 3 0 3 Desig...

Страница 2: ...o change without notice Ask factory for the current technical specifications before purchase and or use Should a safety concern arise regarding this product please be sure to contact us immediately 20...

Страница 3: ...voltage should be made promptly to avoid heat affection The maximum DC Voltage that can be applied specified period without breakdown Performance characteristics Surge energy which can be applied at...

Страница 4: ...d by UN numbers UN classifications etc does not apply to this product In addition when exporting products product specifications and technical information described in this catalog please comply with...

Страница 5: ...Circuit design and circuit board design section 4 Surge absorber placed between a line and the ground When the surge absorber is placed between a line and the ground even if the surge absorber short c...

Страница 6: ...rcuit board design section When surges are applied intermittently to the surge absorber at short intervals when pulses of voltages are applied in a noise simulator test etc make sure that the surge po...

Страница 7: ...e that corresponds to the circuit voltage of a circuit including the current fuse For the HF series surge absorber select the rated current of the fuse after confirming the way the fuse handles a load...

Страница 8: ...to the outer sheath resin Processing conditions 621 821 or higher 182 112 511 182 Power supply voltage AC 100 V 220 V 220 V 240 V 380 V D type SMD type 201 to 361 241 to 431 471 to 621 471 to 621 511...

Страница 9: ...75 or lower and use the surge absorber within two years of storage Check the solderability of a surge absorber stored for a long period two years or more before using the surge absorber Keep the surg...