background image

13

Power LED

LED Display change 

button

Temperature sensor LED 

PoE LIM. LED  

Status/ECO mode LED 

GIGA mode LED 

DUPLEX mode LED 

Loop History mode LED

 POWER LED (Power)

Green Light 

: Power is ON.

Off 

: Power is OFF.

 PoE LIM. LED (PoE limit)

For silent fan control high-speed (High)*  For factory default, or low-speed (Low2)

Off 

: Supplying power in the range from 0 to 355 W. 

Green Light 

: Supplying power in the range from 355 to 370 W. 

Orange Blink   

: A single port's power supply is exceeding the upper limit, or 

the total power supply of the Ethernet Switch is exceeding 370 W. 

For silent fan control low-speed (Low1), or min-speed (Min)

Off 

: Supplying power in the range from 0 to 153 W. 

Green Light 

: Supplying power in the range from 153 to 168 W. 

Orange Blink   

: A single port's power supply is exceeding the upper limit, or 

the total power supply of the Ethernet Switch is exceeding 168 W. 

 TEMP LED (Temperature sensor)

Green Light 

: The system is normally operating. 

Orange Blink   

: The temperature exceeded the set threshold of the internal 

temperature sensor.
Set threshold of the internal temperature sensor: 61°C 
(factory default)

 FAN (Fan sensor) LED

Green Light 

: The system is normally operating.

Orange Blink   

: Fan failure

 STATUS/ECO LED (Status/ECO mode)

Green Light 

: Operating in status mode.

Green Blink 

: Operating in ECO mode.

All Port LEDs (left) are turned off.

Orange Light 

: Starting

Orange Blink 

: Malfunction (Contact the seller.)

 GIGA (GIGA mode) LED

Green Light 

: Operating in GIGA mode.

 FULL (DUPLEX mode) LED

Green Light 

: Operating in DUPLEX mode.

 LOOP HISTORY LED (Loop History mode)

Green Light 

: Operating in Loop History mode.

Green Blink 

: Loop is occurring, or occurred within 

the last 3 days.

Off 

: No loop detection.

Fan sensor LED 

Содержание GA-ML24TPoE+

Страница 1: ...sassembly of this Ethernet Switch by customers are not covered by the warranty The instruction manuals Menu Version CLI Version Web Version latest firmware and SDN application ZEQUO assist Plus can be downloaded from the following URL https panasonic co jp ls plsnw english datadownload index html C0620 21021 Printed in Japan GA ML24TPoE Model No PN262493 TH PN262493 MY PN262493 ID PN262493 SG PN26...

Страница 2: ...res 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 2 1 LED display change 2 2 PoE power supply function 3 Installation and Configuration 3 1 Grounding Cable Connection 3 2 Mounting to rack 3 3 Configuration of IP address Basic Troubleshooting 3 7 8 8 9 11 11 12 15 17 18 18 19 20 22 ...

Страница 3: ...ad to fire electric shock and or equipment failure Do not damage the power cord Do not bend too tightly stretch twist bundle with other cord pinch put under a heavy object and or heat it Damaged power cord could lead to fire short and or electric shock Do not unplug nor plug in the power plug with wet hands Deviation could lead to electrical shock and or equipment failure Do not insert or drop for...

Страница 4: ...ound terminal screw Connect the power cord firmly to the power port Otherwise this might cause electrical shocks and malfunctions Unplug the power cord if the STATUS ECO LED Status ECO mode or FAN LED Fan sensor blinks in orange system fault Deviation such as keep connecting for a long time could lead to fire Handle the Ethernet Switch carefully to prevent fingers and hands from being damaged by t...

Страница 5: ...mmunication lines Isolate distribution lines and other distribution lines and low current power lines optical fiber cables metallic water conduits and gas conduits etc Noise may be generated in the communication lines which might cause communication glitches Do not connect any other devices except for 10BASE T 100BASE TX 1000BASE T devices to the twisted pair ports Deviation could lead to equipmen...

Страница 6: ...air cable leading to malfunction If you connect such a device it is strongly recommended that you install a surge protective device SPD on the twisted pair port side of this Ethernet Switch A lightning surge current voltage may be conducted to this Ethernet Switch through the power supply or ground wire connected to the power port leading to malfunction If a lightning surge current voltage may flo...

Страница 7: ...liquid water Dusty Possible static charge such as carpet Under direct sunlight Possible condensation High low temperature exceeding the specifications environment Strong vibration and or strong shock Failure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfunction Such events are not covered by the warranty If it is used beyond the operating environm...

Страница 8: ...guration changes and verifications of the Ethernet Switch Remotely configure the PoE settings for each port Ports 1 to 24 The connection status for each port is detected by the power saving mode and it can suppress the power consumption to required volumes when not linked up Factory default disabled Rapid Spanning Tree Protocol is supported allowing to build a system with redundancy The IEEE802 1p...

Страница 9: ...n Link Aggregation IEEE802 3ad Configurable up to 14 groups Max 8 ports per group VLAN IEEE802 1Q tagging VLAN protocol compatible Max 256 groups including the default VLAN Port based VLAN Internet Mansion function QoS IEEE802 1p compatible Supports 8 priority queues Management method ZEQUO assist Plus SNMP v1 v2c v3 Telnet SSH v2 Console WEB control screen Power supply function Ports 1 to 24 supp...

Страница 10: ...Switch power will be shut off Others STP RSTP MSTP Supports the IEEE802 1X authentication MAC based port based MAC authentication WEB authentication Triple authentication STEP authentication IEEE802 1X supplicant Port monitoring Ring protocol IGMP snooping Loop detection shutoff function Storm control DSCP mapping function Login RADIUS function DHCP client function PoE scheduler function PoE auto ...

Страница 11: ...ts in green STATUS ECO LED Status ECO mode lights in orange and self diagnosis of hardware is executed On completion of self diagnosis POWER LED Power STATUS ECO LED Status ECO mode TEMP LED Temperature sensor and FAN LED Fan sensor light in green and the Ethernet Switch starts operation as an Ethernet Switch As this Ethernet Switch succeeds in communicating with a terminal connected to each port ...

Страница 12: ... confirming with IEEE802 3at af Devices such as 10 100 1000BASE T terminal hub repeater bridge and Ethernet Switch can be connected to this port Install the device so that the length of twisted pair cable CAT5e or above becomes 100m or less SFP extension slot ports 25 28 Install SFP module It becomes exclusive usage with twisted pair port When SFP extension slot is linked the ports are automatical...

Страница 13: ... port s power supply is exceeding the upper limit or the total power supply of the Ethernet Switch is exceeding 168 W TEMP LED Temperature sensor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the internal temperature sensor Set threshold of the internal temperature sensor 61 C factory default FAN Fan sensor LED Green Light The system is nor...

Страница 14: ...lex or no device is connected Green Light Orange Blink Off LOOP HISTORY Green Light Loop has been detected within the last 3 days Off No loop detection history It is shut off via the loop detection and shutoff function storm control or the BPDU guard PoE are being supplied power Power is not being supplied or the PoE receiving equipment are not connected Also it is set in the ECO mode Single port ...

Страница 15: ...atically returns to a Base mode Status mode or ECO mode The Base mode is maintained even after the power is turned OFF Indication on the front panel and LED lamps You can display the following items using the LED display switch button Display for the connection with a connected terminal Status mode Display for the 1000 Mbps transmission rate GIGA mode Display for the full duplex or half duplex tra...

Страница 16: ...mode The Base mode is maintained even after the power is turned OFF LED lamps for each mode and LED lamps for ports 1 to 28 correspond as shown in Table 1 see page 14 Turns on the port LED with a orange light when a loop occurs in the corresponding port The Loop shutoff mode has the following 2 types of modes Block mode factory default When loops are detected the port statuses are automatically bl...

Страница 17: ...or the total power supply of the Ethernet Switch is exceeding 168 W 1 When configured IEEE802 3at factory default Exceeds 15 4 W when configured IEEE802 3af When the requested power supply for the Ethernet Switch is exceeded and it gets overloaded the power supply to the low priority ports is stopped and the port LEDs right of the ports whose power supply have been stopped blink orange The priorit...

Страница 18: ... cable must be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed during normaI operation servicing or maintenance 5 Installation steps Step 1 Ensure the detachable power ...

Страница 19: ...xing the mount brackets and the Ethernet Switch Fix the mount brackets to the four holes on each side of the Ethernet Switch using the screws Then securely install the Ethernet Switch on the rack using the four provided screws for mounting on a 19 inch rack or screws provided with the rack ...

Страница 20: ...sing the following command Screen 3 enable configure config interface vlan 1 config if ip address 192 168 1 254 255 255 255 0 5 Enter the following command to save the setting config if exit config exit copy running config startup config 6 Once the following screen is displayed enter Y and the settings will be saved Screen 4 Confirm that the settings have been normally saved Screen 5 7 After confi...

Страница 21: ...n 1 GA ML24TPoE config if ip address 192 168 1 254 255 255 255 0 GA ML24TPoE config if GA ML24TPoE Product Number PN262493 Firmware Version x x x xx MAC Address 00 50 40 xx xx xx Serial Number xxxxxxxxxxx UserName manager Password GA ML24TPoE enable GA ML24TPoE configure GA ML24TPoE config interface vlan 1 GA ML24TPoE config if ip address 192 168 1 254 255 255 255 0 GA ML24TPoE config if exit GA M...

Страница 22: ...0BASE TX or 1000BASE T standard Auto negotiation may have failed Check the port settings of this Ethernet Switch or the terminal settings Is the correct Port LED display mode selected using the LED display switch button The Port LED left lights in orange Loop is occurring By removing the loop orange LED will be turned off LOOP HISTORY LED Blinks in green This is to notify that there is a port in w...

Страница 23: ...supply may not be possible depending on the installation environment In such cases use a UTP cable Is a CAT5e or better straight cable RJ45 8 8 used Is the cable connected to the port 1 24 that supports PoE power supply Ensure that either the port alone or the entire equipment is not overloaded Is the Powered Device connected to the port compliant with the IEEE802 3at standard or IEEE802 3af stand...

Отзывы: