background image

7

PRO3

PRO3 mode can load configuration settings from the data bank, i.e.
“channel”, and save configuration settings to the data bank.

PRO4

PRO4 mode is used mainly to configure communication with sub units.
Communication takes place only in the direction shown in the following
diagram.

PRO5

PRO5 mode allows you to make multiple settings at once based on codes,
adjust lock functions and reset the unit.

The 0-ADJ setting function was removed in May, 2005.

Code setting table

Mode

Setting

Description

Press the jog switch to load configuration 
settings from the respective channel (1, 2 or 

3). When the display blinks 

, press 

the jog switch to confirm.

Press the jog switch to save configuration 
settings to the respective channel (1, 2 or 3). 

When the display blinks 

, press the 

jog switch to confirm.

Mode

Setting

Description

_

Except for data bank information, settings 
are copied to the sub units.

Press the jog switch to load the configuration 
settings from each amplifier’s respective 
remote channel (1, 2 or 3). When the display 

blinks 

, press the jog switch to con-

firm.

Press the jog switch so that each amplfier 
saves its configuration settings to the 
respective remote channel (1, 2 or 3). When 

the display blinks 

, press the jog 

switch to confirm.

Communication lock function OFF.
You can load and save settings remotely.

Communication lock function ON.
You cannot load or save settings remotely.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

When copying data from the 4th unit, it will be copied to units 
5 and up, but not to units 1-3.

Direction of communication

When copying data from the 1st unit, it will be copied to all sub units.

Back-up ON.

Back-up OFF.
Prevents frequent overwriting of data in the 
EEPROM: the threshold values are not 
stored in the EEPROM when teaching via 
external input, e.g. with the FX-CH2 external 
input unit for digital sensors.

Mode

Setting

Description

( F a c t o r y
setting.)

Choose a code from the code setting table 
(See “Code setting table” on page 7.)
If any other code is entered, ' - ' is displayed.

1

Press the jog switch to select the first digit
in the code.

2

Turn the jog switch to select a number.

3

Press the jog switch to confirm the
number and move to the next digit.

Adjust lock ON.
You cannot adjust the threshold value in 
RUN mode.

Adjust lock OFF.
You can adjust the threshold value in RUN 
mode.

Press the jog switch to reset the unit.
Press <MODE> to cancel.

Mode

Setting

Description

5s

4s

3s

2s

1s

1ms

5ms

10ms

30ms

50ms

100ms

300ms

500ms

3ms

Std

S-d

Lon9

FASt

FASt

FASt

Lon9

Lon9

Std

Std

H-02

H-03

H-03

H-01

H-02

H-02

H-02

H-03

H-01

H-01

L-On

L-On

L-On

L-On

d-On

d-On

d-On

d-On

L-ON/

D-ON

digt

digt

---P

---P

PHLd

PHLd

bHLd

bHLd

non

ofd

ofd

ond

ond

osd

osd

non

ON

OFF

OFF

OFF

OFF

ON

ON

ON

1st digit

2nd digit

3rd digit

4th digit

Timer

Code

Timer

operation

Adjust 

lock

Code

Display

Code

Hysteresis

Response 

time

Code

OFF

Содержание FX-301 Series

Страница 1: ... to the connector type sensor FX 301 P Avoid dust dirt and steam Take care that the sensor does not come in contact with oil grease organic solvents such as thinner etc strong acid or alkaline Do not use this sensor in an environment containing inflammable or explosive gases Never disassemble or modify the sensor You may break the spring hook if you do not follow the mounting instructions carefull...

Страница 2: ...tional version units as viewed from the connector side For details see page 8 section 16 UNIT VERSIONS Only the interference prevention function can be transmitted between this product and other digital fiber amplifiers Therefore mount identical models together when mounting in cascade Please note the interference prevention function is not incorporated in the FX 301 P HS Be careful when the senso...

Страница 3: ...UIT DIAGRAMS Symbol Meaning D Reverse supply polarity protection diode ZD Surge absorption zener diode Tr1 NPN output transistor Tr2 PNP output transistor 8 OPERATION PROCEDURE MODE key Jog switch Press Press Turn side side V 0V 1 3 2 Output D1 1 2 3 Tr1 ZD1 10 12 to 24V DC Internal circuit Users circuit Brown V note Load Black Output Sensor circuit 100 mA max note Blue 0V note Color of core wire ...

Страница 4: ...ty and the TEACH mode indicator blinks 3 Turn the jog switch to the side or the side to set the shift for the threshold value 1 A comma scrolls from right to left across the display twice 4 The judgement for the sensing stability is displayed briefly sensing stable stable sensing not possible 5 The threshold value is displayed briefly 6 The actual incident light intensity is displayed and the sett...

Страница 5: ...ription 1 Press MODE briefly and repeatedly until the ADJ operation indicator is lit 2 Turn the jog switch to the side to increase the threshold value i e decrease sensitivity or to the side to lower the threshold value i e increase sen sitivity 3 Press the jog switch briefly to confirm the setting 11 OUTPUT OPERATION MODE Step Description 1 Press MODE briefly and repeatedly until the L D operatio...

Страница 6: ...nts of 5 Reflective type fiber If the threshold value is shifted toward the direction minute detections are possible Thru beam type fiber If the threshold value is shifted toward the direction minute detections are possible 4 Level 4 Highest emitting power Level 3 Level 2 Level 1 Lowest emitting power Emission halt While in RUN mode is displayed when the emission halt state is valid 1 The S d sett...

Страница 7: ...tings remotely 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 When copying data from the 4th unit it will be copied to units 5 and up but not to units 1 3 Direction of communication When copying data from the 1st unit it will be copied to all sub units Back up ON Back up OFF Prevents frequent overwriting of data in the EEPROM the threshold values are not stored in the EEPROM when teaching via external inp...

Страница 8: ...s the original version Modified unit Conventional unit When mounting the modified version units and conventional version units together in cascade place the modified version units on the right of the conventional version units as viewed from the connector side 14 KEY LOCK FUNCTION 15 ERROR INDICATION Display Error Description Measures The load is short cir cuited causing overcur rent Turn off the ...

Страница 9: ...ess STD 250μs or less LONG 2ms or less Display 4 digit red LED display Sensitivity setting 2 point teaching limit teaching full auto teaching manual adjustment Sensitivity adjustment function 3 3See THRESHOLD VALUE ADJUSTMENT MODE on page 5 Incorporated Timer function Incorporated Available modes off ON delay OFF delay ONE SHOT timer Timer interval range approx 0 5 to 9999ms Interference preventio...

Отзывы: