Panasonic FX-301 Series Скачать руководство пользователя страница 3

3

Terminal arrangement diagram, FX-301 connector type

The following symbols are used in this section.

NPN output type

PNP output type

50mA max. if five or more connector type FX-301(P) amplifiers are 

connected in cascade.

When the power supply is switched on, a communication self-check is
executed. The RUN mode indicator lights up green and the digital display
shows the incident light intensity.

The terminology in the following table will help you navigate through the
various modes and make your settings.

General navigation tips

Press <MODE> briefly and repeatedly to switch from mode to mode.

Press <MODE> for 2s or more to return to RUN mode.

To cancel the setting process, press <MODE>.

Press the jog switch to confirm settings.

Turn the jog switch to navigate between sub-modes.

When the jog switch is turned in RUN mode, the current threshold value
is displayed. Then the current incident light intensity is displayed again
automatically

Navi mode

Starting in RUN mode, you will navigate through the modes in the following
order. 

7

I/O CIRCUIT DIAGRAMS

Symbol

Meaning

D

Reverse supply polarity protection diode

Z

D

Surge absorption zener diode

Tr

1

NPN output transistor

Tr

2

PNP output transistor

8

OPERATION PROCEDURE

MODE key

Jog switch

Press

Press

Turn

"+" side

"-" side

 +V

0V

1

3

2

Output

D

1

1

2

3

T

r1

+

-

Z

D1

±10%

12 to 24V DC

Internal circuit

Users' circuit

(Brown) +V (note)

Load

(Black) Output

Sensor circuit

100 mA max. (note)

(Blue) 0V (note)

Color of core wire of the main quick-
connection cable

Terminal no.

D

2

Z

D2

1

2

3

T

r2

+

±10%

-

12 to 24V DC

Internal circuit

Users' circuit

(Brown) +V (note)

Load

(Black) Output

Sensor circuit

100 mA max. (note)

(Blue) 0V (note)

Color of core wire of the main quick-
connection cable

Terminal no.

Mode

Description

RUN

Normal sensing operation.

TEACH

Sets threshold value by “2-point teaching”, “limit teach-
ing”, or “full-auto teaching”.
See “TEACHING MODE” on page 4.

ADJ

Allows fine adjustment of the threshold value.
See “THRESHOLD VALUE ADJUSTMENT MODE” on 
page 5.

L/D

Sets output operation to either Light-ON or Dark-ON.
See “OUTPUT OPERATION MODE” on page 5.

TIMER

Configures operation of the timer.
See “TIMER OPERATION MODE” on page 5.

PRO

Press the jog switch to enter the PRO sub-
modes, which allow you to make various 
detailed settings.

See “PRO MODE” on page 5.

RUN

Normal sensing operation.

Содержание FX-301 Series

Страница 1: ... to the connector type sensor FX 301 P Avoid dust dirt and steam Take care that the sensor does not come in contact with oil grease organic solvents such as thinner etc strong acid or alkaline Do not use this sensor in an environment containing inflammable or explosive gases Never disassemble or modify the sensor You may break the spring hook if you do not follow the mounting instructions carefull...

Страница 2: ...tional version units as viewed from the connector side For details see page 8 section 16 UNIT VERSIONS Only the interference prevention function can be transmitted between this product and other digital fiber amplifiers Therefore mount identical models together when mounting in cascade Please note the interference prevention function is not incorporated in the FX 301 P HS Be careful when the senso...

Страница 3: ...UIT DIAGRAMS Symbol Meaning D Reverse supply polarity protection diode ZD Surge absorption zener diode Tr1 NPN output transistor Tr2 PNP output transistor 8 OPERATION PROCEDURE MODE key Jog switch Press Press Turn side side V 0V 1 3 2 Output D1 1 2 3 Tr1 ZD1 10 12 to 24V DC Internal circuit Users circuit Brown V note Load Black Output Sensor circuit 100 mA max note Blue 0V note Color of core wire ...

Страница 4: ...ty and the TEACH mode indicator blinks 3 Turn the jog switch to the side or the side to set the shift for the threshold value 1 A comma scrolls from right to left across the display twice 4 The judgement for the sensing stability is displayed briefly sensing stable stable sensing not possible 5 The threshold value is displayed briefly 6 The actual incident light intensity is displayed and the sett...

Страница 5: ...ription 1 Press MODE briefly and repeatedly until the ADJ operation indicator is lit 2 Turn the jog switch to the side to increase the threshold value i e decrease sensitivity or to the side to lower the threshold value i e increase sen sitivity 3 Press the jog switch briefly to confirm the setting 11 OUTPUT OPERATION MODE Step Description 1 Press MODE briefly and repeatedly until the L D operatio...

Страница 6: ...nts of 5 Reflective type fiber If the threshold value is shifted toward the direction minute detections are possible Thru beam type fiber If the threshold value is shifted toward the direction minute detections are possible 4 Level 4 Highest emitting power Level 3 Level 2 Level 1 Lowest emitting power Emission halt While in RUN mode is displayed when the emission halt state is valid 1 The S d sett...

Страница 7: ...tings remotely 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 When copying data from the 4th unit it will be copied to units 5 and up but not to units 1 3 Direction of communication When copying data from the 1st unit it will be copied to all sub units Back up ON Back up OFF Prevents frequent overwriting of data in the EEPROM the threshold values are not stored in the EEPROM when teaching via external inp...

Страница 8: ...s the original version Modified unit Conventional unit When mounting the modified version units and conventional version units together in cascade place the modified version units on the right of the conventional version units as viewed from the connector side 14 KEY LOCK FUNCTION 15 ERROR INDICATION Display Error Description Measures The load is short cir cuited causing overcur rent Turn off the ...

Страница 9: ...ess STD 250μs or less LONG 2ms or less Display 4 digit red LED display Sensitivity setting 2 point teaching limit teaching full auto teaching manual adjustment Sensitivity adjustment function 3 3See THRESHOLD VALUE ADJUSTMENT MODE on page 5 Incorporated Timer function Incorporated Available modes off ON delay OFF delay ONE SHOT timer Timer interval range approx 0 5 to 9999ms Interference preventio...