How to use

How to use

Control Panel

Control Panel

Insert the plug into the power socket. With a beep, all the buttons on the control panel light up and last for about 
1 seconds, and then go out.

 

Power on/off 

Power on/off 
Touch the   button, all the buttons light up with a beep (the

 button turns white, the fan speed buttons 

 

 

 turn white lowlight, and the LIGHT button 

 turns white lowlight) and the unit enters power-on state.

Touch the   button in power-on state, all the buttons go out with a beep, and the unit enters the power-off 
state.

 

Fan speed setting

Fan speed setting
In power-on state, touch the 

 

 

 button to set the fan speed with a beep. (the

 button turns white, the 

fan speed button being touched turns white highlight, and the fan speed buttons not being touched turns white 
lowlight). The fan speed can be switched between "LOW", "HIGH" and "ULTRA HIGH" by touching fan speed 
buttons.
When touching the fan speed button showing white highlight in the working state of the fan, the fan will stop 
running with a beep.

 

Ultra high speed

Ultra high speed
In standby state, touch the 

 button, the backlight of the button fl ashes with a beep. After the fan has been 

running for 3 minutes in ULTRA HIGH mode, the fan enters a running state of HIGH mode with a beep; touch 
the 

 button again within 3 minutes, the fan stops working with a beep.

 

Light on/off

Light on/off
Touch the 

 button in power-on/off state, the LIGHT turns on/off with a beep.

 

Latency switch function

Latency switch function
Touch the   button when the fan is on, the backlight of the 

button fl ashes with a beep, and the range hood 

starts to perform the "Power-off latency" function. The fan will stop running automatically after running at low 
speed for 3 minutes.
And the LIGHT turns off at the same time.

If you change the fan speed during the latency, the fan will work at the speed you set, and the current latency 

 

 function will be canceled.

 

 In this case, the LIGHT remains unchanged.

If you touch the   button during the latency, the current latency function will be canceled and the unit will 

 

 enter the power-off state.

 

 In this case, the LIGHT remains unchanged.

6

Содержание FV-KTB2SD1HK

Страница 1: ...o follow the instructions in this manual may result in personal injury or property damage After installation please explain to the user how to operate and maintain Panasonic products and give this man...

Страница 2: ...ert sharp metal into any gaps in the unit So as not to touch the inside of the unit and cause electric shocks Do not install remove disassemble modify or reinstall this product by yourself Do not inst...

Страница 3: ...ly cord is damaged it must be replaced by the manufacturer its service agent If the supply cord is damaged it must be replaced by the manufacturer its service agent similarly quali ed persons similarl...

Страница 4: ...to cause malfunctions or burns due to high temperature of the unit The product shall be installed on a wall that is strong enough If installation strength cannot be The product shall be installed on a...

Страница 5: ...art names and sizes Part names and sizes Unit mm Fan guard Adapter Duct cover Oil cup PCB cover Power cord Control panel LED lamp Dimensions L W 300 8 mm 24 2 mm Max input power 3 0 W Voltage input DC...

Страница 6: ...state of the fan the fan will stop running with a beep Ultra high speed Ultra high speed In standby state touch the button the backlight of the button ashes with a beep After the fan has been running...

Страница 7: ...at a temperature of 40 to 50 wait for 5 to 10 minutes and clean the oil cup Put back the oil cup in place refer to removal of the oil cup The direction to remove oil cup Usually just wipe the surface...

Страница 8: ...own away due to high air volume in the kitchen 4 The distance between the cooking stove and the range hood is too far 1 Contact the Customer Consulting Service Center for reinstalling of the smoke duc...

Страница 9: ...Net weight the weight of the body plus the weight of oil cup and adapter The parameters above are subject to change without notice Rated voltage 220 V Rated frequency 50 Hz Rated power input 298 W Ra...

Страница 10: ...T5 19 1 Oil cup 1 Stop block 1 Operation Installation Instructions 1 Smoke duct With aluminum foil tape 1 Duct adapter 1 Short duct adapter Fixed on smoke duct 1 Adapter 1 Sealing pad Fixed on applian...

Страница 11: ...od shall be aligned with the center of cooking stove Do not install it in the place exposed to direct sunlight Ensure that the gas can be discharged to outside or common ue through smoke duct If you n...

Страница 12: ...t bulging or compressed and it bends freely If the smoke duct is extended directly into the common ue it shall not go too deep into the common ue so as not to affect exhaust effect if oil fume is exha...

Страница 13: ...and check the following items After installation tear off the protective lm from the duct cover Install the oil cup at the bottom of the unit Do the fan blades rotate properly Is there any abnormal vi...

Страница 14: ...14...

Отзывы: