Panasonic FV-10VEC2 Скачать руководство пользователя страница 17

17

Make sure the direction of the arrow 

on the OA filter is correct.

2

Latch

Frame cover

Lock plate

MAINTENANCE

AIR FLOW

AIR FLO

W

AIR FLOW

AIR FLOW

1

Main 

switch

Filter reset

button

I

O

10

20

30

40

50

60

50

60

70

80

90

100

50

60

70

80

90

100

Supply Air

Air fourni

(CFM)

(CFM)

min/h

min/h

Exhaust Air

Air 

d'évacuation

Filter

Reset

Button

Bouton de 

réinitialisation

du filtre

(pi

3

/min)

(pi

3

/min)

It is suggested to replace the OA filter 

every 6 months. Please fill in beginning 

time on new OA filter before replacing.

Please replace OA filter by Panasonic 

Model FV-FL0810VE1 or FV-FL1310VE1.

OA filter

RA filter

BEGINNING TIME:

OA filter

RA filter

Energy recovery core

1

2

2

Clean the OA filter, RA filter and energy 

recovery core.

5

Connect power, press filter reset button  with sound of beep, then filter indicator and 

buzzer sound will be off.

1

2

3

Reinstall the filters.

4

Reinstall and close frame cover by locking the latches, then reset the lock plate.

Содержание FV-10VEC2

Страница 1: ...ailure to comply with instructions could result in personal injury or property damage Please explain to users how to operate and maintain the product after installation and this booklet should be pres...

Страница 2: ...f fire or electric shock do not use this unit with any solid state control device This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the uni...

Страница 3: ...ear the fan motor fixture or wiring cover For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors Sufficient air is needed for proper combustion and exhausti...

Страница 4: ...into the incoming cold air and pre cooling and reducing the humidity of the incoming hot air This helps maintain a fresh environment even when the heating or cooling system is not operating Heating Co...

Страница 5: ...l Neutral Earth ground Live Live WHITE BLACK GREEN Wire Nuts FV 10VEC2H FV 10VE2H Only FV 10VEC2H R JUNCTION BOX GREEN WHITE BLACK GROUND NEUTRAL LIVE R G G Installation work and electrical wiring mus...

Страница 6: ...the HVAC AHU please open knock out holes for wall switch and boost switch connection only 4 Insert wires into the corresponding terminals deeply through the ribs Make sure the screw of terminal secure...

Страница 7: ...e on wall bracket according to the distance between studs Unit inches mm A B 24 609 6 16 406 4 19 482 6 17 1 2 444 5 14 1 2 368 3 22 1 2 571 5 A B Stud 4 long screws ST4 2X30 Stud Wall bracket Floor E...

Страница 8: ...t straight run on all duct attachments points before elbow is more than 2 ft 610 mm 2 Unit is normally balanced on high speed with the furnace blower on 3 A minimum separation of 40 inches 1 m is reco...

Страница 9: ...allation Note 1 The ERV unit must be balanced 2 It is mandatory that HVAC AHU signal cord be connected 3 Check local codes and authority having jurisdiction for acceptance Note 1 Must Have 2 3 ft stra...

Страница 10: ...and living areas Method Fully dedicated ducted installation Note 1 The ERV unit must be balanced 2 Check local codes and authority having jurisdiction for acceptance Note 1 Must Have 2 3 ft straight...

Страница 11: ...o the OA and EA adapter 1 2 Attach duct rigid galvanized duct etc to the SA and RA adapter Please refer to the local codes for detail The intake side duct must be connected to the outside and at least...

Страница 12: ...ains are not supplied Please purchase chains which must be subjected to the weight of 66 lbs 30 kg or above 2 Make sure ERV is horizontal after installation Note Chain Hanger Hanger Install Hanger Ins...

Страница 13: ...on off 1 2 3 4 SA knob Set the supply air volume with this knob The factory default is 100 CFM The unit will consume some electricity unless you turn off the main switch OPERATION Note The SA air vol...

Страница 14: ...the customer to set as ASHRAE 50 min h SA 90 CFM EA 90 CFM ON ON OFF when boost switch is ON ERV enforces the instructions ASHRAE 60 min h SA 100 CFM EA 100 CFM when boost switch is OFF ERV restores...

Страница 15: ...C 104 F 40 C FV 10VE2 FV 10VE2H OA damper open Heat exchange mode Outside air OA Exhaust air EA Supply air SA Return air RA Supply air SA Return air RA Example of FV 10VEC2 and FV 10VEC2H Outdoor tem...

Страница 16: ...wer by switching off main switch first then unplug before working on unit when it is in default mode CAUTION Routine maintenance must be performed every 2 or 3 months clogged filters may cause condens...

Страница 17: ...pi3 min pi3 min It is suggested to replace the OA filter every 6 months Please fill in beginning time on new OA filter before replacing Please replace OA filter by Panasonic Model FV FL0810VE1 or FV F...

Страница 18: ...iring connect SA motor error please disconnect the power and contact the dealer for repair Off Blink 2 s Blink 2 s EA motor error please disconnect the power and contact the dealer for repair OA dampe...

Страница 19: ...6 SPECIFICATIONS Weight Ib For FV 10VEC2 and FV 10VEC2H To ensure quiet operation of the ENERGY STAR certified H ERV each product model must be installed using sound attenuation techniques appropriat...

Страница 20: ...c com Panasonic Corporation 2023 Issue date 05 2023 Warning Concerning Removal of Covers The unit should be serviced by qualified technicians only Your product is designed and manufactured to ensure a...

Отзывы: