background image

10

PRODUCT SERVICE

Warning Concerning Removal of Covers.

The unit should be serviced by qualified technicians only.
Your product is designed and manufactured to ensure a minimum of maintenace.
Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299(USA)
Or 1-800-669-5165(Canada).

Panasonic Corporation of North America

Two Riverfront Plaza, Newark, NJ 07102
www.panasonic.com

Panasonic Canada Inc.

5770 Ambler Drive, Mississauga, Ontario L4W 2T3
www.panasonic.ca

©

 Panasonic Corporation 2002-2015

Printed in China

P0502-60915  10NLF10750F

Model No.

Air 

direction

V

Hz

Power 

consumption 

(W)

Speed 

(PRM)

Air delivery 

(CFM)

Weight 

K

g

 (lb.)

FV-10NLF1E

Exhaust

120

60

30

1510

120

6.3(13.9)

FV-20NLF1

57

1260

240

7.5(16.5)

FV-30NLF1

98

1340

340

10.9(24.1)

FV-40NLF1

132

1150

440

11.9(26.3)

SPECIFICATIONS

*Power consumption, speed and air delivery values have been measured at 5mm WG (0.2’’ WG).

Содержание FV-10NLF1E

Страница 1: ...ions could result in personal injury or property damage Please explain to users how to operate and maintain the product after installation and this booklet should be presented to users Please retain this booklet for future reference Contents GENERAL SAFETY INFORMATION 2 3 DESCRIPTION 4 UNPACKING 4 SUPPLIED ACCESSORIES 4 DIMENSIONS 5 INSTALLATION I HORIZONTALLY BETWEEN JOISTS 5 7 INSTALLATION II ON...

Страница 2: ... reduce the risk of fire electric shock or personal injury observe the following Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combust...

Страница 3: ...e certain that the service supply voltage is 120V 60Hz Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Always switch the power source off before working on or near the fan or motor Protect the electrical wires from sharp edges oil grease hot surfaces chemicals or other objects Do not bend the electrical wires Do...

Страница 4: ...oise level It also incorporates a thermal cutout for safety UNPACKING Unpack and carefully remove unit from carton Refer to the supplied accessories list to verify that all parts are present SUPPLIED ACCESSORIES Part name Illustration Quantity Bracket 2 Hanger 1 Bracket cover 2 Installation bracket 2 Extension bracket 2 Holder Assembled on body 2 Long screw 10 Self tapping screw 12 Short screw 4 ...

Страница 5: ...600 23 5 8 280 11 1 32 38 1 1 1 2 8 5 16 321 661 12 5 8 26 242 9 17 32 142 5 19 32 158 6 7 32 FV 40NLF1 420 16 17 32 340 13 3 8 560 22 1 6 280 11 1 32 38 1 1 1 2 8 5 16 321 661 12 5 8 26 242 9 17 32 195 7 11 16 211 8 5 16 Dimensions mm inch Fig 1 Ceiling joist Hanger Long Screw Ceiling board A INSTALLATION I HORIZONTALLY BETWEEN JOISTS 1 Disconnect the power to the receptacle before starting the i...

Страница 6: ...xtension bracket Short screw Dimension mm inch MODEL FV 10NLF1E FV 20NLF1 FV 30NLF1 FV 40NLF1 B 381 15 421 16 1 2 461 18 1 8 461 18 1 8 table 2 5 Insert the holder located on the unit into the hanger Fig 3 6 Attach the In Line Fan to a joist or a pillar with the long screws Fig 4 7 Remove junction box cover and secure conduit or wire holder to junction box cover knockout hole Fig 5 8 Using wire nu...

Страница 7: ...on bracket into the bracket cover attached to the panel 2 Extend installation bracket and put the unit on the ceiling or joist Secure with long screws Fig 7 3 Remove junction box cover and secure conduit or wire holder to junction box cover knockout hole Fig 5 4 Using wire nuts connect house power wire as shown in the wiring diagram on page 7 5 Replace junction box cover CAUTION Mount junction box...

Страница 8: ...iring diagram 5 Replace junction box cover CAUTION Mount junction box cover carefully so that wires are not pinched Wiring Diagram Fuse in Motor FV 10NLF1E 134 C FV 20NLF1 167 C FV 30NLF1 134 C FV 40NLF1 134 C Thermally protected Motor Red Blue Black White Green Junction box Power Supply 120V 60Hz Capacitor Fan body Earth ground G 6 Install circular ducts on both ends and secure them with tape or ...

Страница 9: ...ic Our fans and fan light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor s fan light combination Our efficient cool running motors and our fluorescent lamps do not create enough ambient heat to be subjected to these limitations The ducting from this fan to the outside of the building has a strong effect on the air flow noise ...

Страница 10: ...ca Two Riverfront Plaza Newark NJ 07102 www panasonic com Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 www panasonic ca Panasonic Corporation 2002 2015 Printed in China P0502 60915 10NLF10750F Model No Air direction V Hz Power consumption W Speed PRM Air delivery CFM Weight Kg lb FV 10NLF1E Exhaust 120 60 30 1510 120 6 3 13 9 FV 20NLF1 57 1260 240 7 5 16 5 FV 30NLF1 98 1340 3...

Отзывы: