background image

Ventilating Fan

FV-05VS1
FV-08VS1

R

EAD AND SAVE THESE INSTRUCTIONS.

R

Please read these instructions carefully before attempting to install,
operate or service the Panasonic Ventilating Fan. Failure to comply
with instructions could result in personal injury and/or property
damage. Please retain this booklet for future reference.

Description

Dimensions
Specifications

Table of Contents

Supplied Accessories

Unpacking

General Safety Information

4

4-5

4

3

2

2

5

Wiring Diagram

13

12

8-9

10

10-11

Installation

( In Existing Construction )

VI

Installation

( Wooden Header )

V

16
16

Maintenance
Practical Guide to Installation

16

Product Service

6-8

I

Installation

( Joist Mounting- )

I

Installation

( Joist Mounting-

)

II

II

( -Joist Mounting )

I

Installation

III

Installation

( Between Joist Mounting )

IV

14-15

I

Installation

( Wall Installation- )

I

V I

Installation

( Wall Installation-

)

II

I

V II

Installation

( Wall Installation-

)

III

IX

12

14

Содержание FV-05VS1

Страница 1: ...Specifications Table of Contents Supplied Accessories Unpacking General Safety Information 4 4 5 4 3 2 2 5 Wiring Diagram 13 12 8 9 10 10 11 Installation In Existing Construction VI Installation Wooden Header V 16 16 Maintenance Practical Guide to Installation 16 Product Service 6 8 I Installation Joist Mounting I Installation Joist Mounting II II Joist Mounting I Installation III Installation Bet...

Страница 2: ...ced energy consumption It also incorporates a thermal cutoff for safety The grille covering the main body is a spring loaded quick release type A damper for preventing counterflow is provided 1 8 1 Thumb screw Long screw M4X30 Quantity Appearance Part name Grille Suspension bracket I Suspension bracket II 1 1 Screw M4X8 I 2 1 Suspension bracket III Screw M4X10 II 2 Spacer 1 ...

Страница 3: ...bracket I III II III FV 05VS1 FV 08VS1 Junction box cover Junction box Motor Blade Part name No Part name No 1 2 3 4 5 6 7 8 9 10 Damper Fan body Adaptor Grille Suspension bracket Bracket cover 1 2 13 3 6 8 95 3 1 8 78 3 1 8 78 1 1 2 38 1 25 2 3 8 60 7 1 0 1 4 2 6 1 1 2 3 0 0 3 76 13 330 10 1 4 261 3 3 4 94 6 9 10 8 1 3 3 3 0 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 ...

Страница 4: ...ource before working on or near the fan motor or junction box 5 Protect the power cord from sharp edges oil grease hot surfaces chemicals or other objects 6 Do not kink the power cord 7 Do not install the unit where ducts are configured as shown in Fig A 8 Provide suction parts with proper ventilation 9 This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected bran...

Страница 5: ... Air Conditioning Engineers ASHRAE and the local code authorities D When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities E Ducted fans must always be vented to the outdoors F These models are UL listed for tub and shower enclosures G Solid state controls may cause harmonic distortion which can cause motor humming noise To reduce the risk of fire ...

Страница 6: ...nter joists is 24 inches connect suspension bracket and C4 mark to C4 mark as shown below II III Joists A Suspension bracket I Fig 2 1 Fan body Suspension bracket I Suspension bracket III Fig 2 2 Fan body Suspension bracket III Suspension bracket I Fig 2 3 Fig 2 4 Fan body Suspension bracket I Suspension bracket III Suspension bracket II Fig 1 Fan body Remove tape Adaptor Damper 1 Before installat...

Страница 7: ...junction box cover Fig 5 CAUTION Mount junction box cover carefully so that lead wires are not pinched 4 Install the suspension bracket to joists by using long screws M4X30 and secure it to the fan body by using screw M4X10 Fig 4 II 3 Install the suspension bracket and the flange of fan body to joists by using long screws M4X30 according to Fig 3 7 Install a circular duct and secure it with duct t...

Страница 8: ...o complete the duct work and wiring I If spacing A between joists is 21 1 4 to 23 1 2 inches connect suspension bracket and C4 mark to C4 mark according to page 6 Select the suspension bracket according to spacing A as shown below II III suspension bracket suspension bracket I suspension bracket III suspension bracket II III Spacing A between Joists inches mm 13 1 4 15 1 2 336 394 16 1 2 18 3 4 41...

Страница 9: ...page 8 to complete the installation work I Fig 12 1 Adaptor 4 Screws Fig 12 4 4 Screws Screw driver Fig 12 3 Fan body Fig 12 2 Fan body Blower When mounting body and blower separately 1 Loosen 4 screws but do not remove them from blower Fig 12 1 2 Remove blower section Fig 12 2 4 Insert fan body without blower section into joists Fig 9 5 Secure the adaptor to fan body by using thumb screw Fig 10 7...

Страница 10: ...age 8 to complete the installation work I 2 Insert the suspension bracket into the bracket cover of adaptor side and the back of the fan body Fig 15 select the suspension bracket according to spacing A as shown below 1 Before installation Secure the fan body to adaptor by using thumb screw Fig 1 of page 6 Fig 13 Fig 14 C C3 C4 C1 C2 Screw M4X10 II Suspension bracket III 4 Long screws M4X30 I joist...

Страница 11: ...m 11 5 Secure the suspension bracket to fan body by using screw M4X10 Fig 18 II 6 Follow step 5 to 9 of installation page 7 page 8 to complete the installation work I Adaptor Fan body Joists Junction box Fig 16 Fig 18 Joist 4 Long screws M4X30 2 Screw M4X10 II CAUTION Ensure that distance B is no more than 1 2 inch 13 mm 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 Suspension ...

Страница 12: ... construction Installing the ventilating fan in an existing building requires an accessible area attic or crawl space above the planned installation location or existing ducting and wiring CAUTION Check area above planning installation location to be sure that 1 Duct work can be done and that area is sufficient for proper ventilation 2 Wiring can be run to planned location 3 No wiring or other obs...

Страница 13: ...inish the wall work wall hole should be aligned with the edge of the flange IMPORTANT Ensure distance C is 3 16 of an inch 5 mm during the installation process as follows 8 Insert the mounting spring into slots and mount grill to fan body refer to step 9 of installation of page 8 I 12 1 8 305 12 1 8 305 inches mm 5 Secure the fan body to the studs by using long screws M4X30 step 5 to step 7 of ins...

Страница 14: ...he installation of page 7 I Fig 28 Fig 27 This installation method is only for 12 inch and 24 inch joists 2 Remove the backing paper from the spacer attach the spacer to the flange of the fan body The holes on the spacer should line up with the holes on the flange Fig 28 3 Secure the suspension bracket into bracket cover of the adaptor for 24 inch joists refer to Fig 2 on page 6 Secure the suspens...

Страница 15: ... Stud 2 Long screws M4X30 Suspension bracket I Spacer Disconnect power source before working on unit Routine maintenance must be done every year WARNING CAUTION 1 Never use petrol benzene thinner or any other such chemicals for cleaning the ventilating fan 2 Do not allow water to enter motor 3 Do not immerse resin parts in water over 60 C o 1 Remove grille Squeeze mounting spring and pull down car...

Страница 16: ...can be placed directly over the fan housing in the attic Panasonic fans and fan light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitors fan light combinations Our efficient cool running motors and our fluorescent bulbs do not create enough ambient heat to be subjected to these limitations Properly insulate the area around the f...

Отзывы: