5.6.2 Settings and Operations of Linear Interpolation
The example below is a case of E-point control with the unit installed in slot 1. The X axis is set
to the 1st axis and the Y axis is set to the 2nd axis. The movement amount setting is the
increment method, and the unit is set to pulse.
Y axis
X axis
10000 pulses
5000 pulses
■
Operation diagram
100
100
f [pps]
10000
t [ms]
Composite speed
Operation done flag of axis 1
Operation done flag of axis 2
BUSY flag of axis 1
BUSY flag of axis 2
Start Condition
■
Operations of each contact
● The BUSY flags of axes 1 and 2 (X28 and X29), which indicate that the motor is running, will
turn ON when the positioning control starts, and it will turn OFF when the operation
completes.
● The operation done flags of axes 1 and 2 (X30 and X31), which indicate the completion of
operation, will turn ON when the current operation is completed, and it will be held until the
next positioning control, JOG operation or home return operation starts.
■
Settings
Item
Setting example
Common area
Axis setting
Turn ON the single axis setting for an appropriate axis.
5.6 Linear Interpolation Control
5-34
WUME-FPXHPOSG-01
Содержание FP-XH Series
Страница 2: ... MEMO 2 WUME FPXHPOSG 01 ...
Страница 18: ... MEMO 1 10 WUME FPXHPOSG 01 ...
Страница 30: ... MEMO 3 8 WUME FPXHPOSG 01 ...
Страница 51: ...4 4 Reading Elapsed Values WUME FPXHPOSG 01 4 21 ...
Страница 52: ... MEMO 4 22 WUME FPXHPOSG 01 ...
Страница 88: ... MEMO 5 36 WUME FPXHPOSG 01 ...
Страница 94: ... MEMO 6 6 WUME FPXHPOSG 01 ...
Страница 140: ... MEMO 9 8 WUME FPXHPOSG 01 ...
Страница 193: ... MEMO WUME FPXHPOSG 01 ...
Страница 194: ...Panasonic Industrial Devices SUNX Co Ltd 2020 October 2020 WUME FPXHPOSG 01 ...