4.1 Confirming I/O Allocation
4.1.1 When Using Pulse Output Table Setting Mode
● The home input signal and positioning completion signal is allocated to I/O signals.
■
Allocation of I/O signals (Input)
Signal name
I/O No.
Axis 1
Axis 2
Axis 3
Axis 4
Axis 5
Axis 6
CH0
CH1
CH2
CH3
CH4
CH5
When using the
transistor output
Control Unit
J-point control
positioning start
input
X0
X1
-
-
-
-
Home input
X4
X5
X6
X7
X2
X3
(Y70)
(Y71)
(Y72)
(Y73)
(Y74)
(Y75)
(Y80)
(Y82)
(Y84)
(Y86)
(Y88)
(Y8A)
(Y81)
(Y83)
(Y85)
(Y87)
(Y89)
(Y8B)
BUSY
X28
X29
X2A
X2B
X2C
X2D
Operation done
X30
X31
X32
X33
X34
X35
Home return done
X48
X49
X4A
X4B
X4C
X4D
When using the
relay output type
pulse I/O cassette
J-point control
positioning start
input
X100
X200
-
-
-
-
Home input
X102
X202
-
-
-
-
(Note 1)
Even when setting the linear interpolation, the interpolation operation is not performed for the home
return. Execute the operation for X axes and Y axes separately.
(Note 2)
The near home input, over limit input (+) and over limit input (-) will be valid when an arbitrary input is
allocated and the output relay indicated in the above table turns ON.
■
Sample program
The following sample shows the program when the near home input, over limit input (+) and
over limit input (-) are allocated to X10 to X12.
4.1 Confirming I/O Allocation
4-2
WUME-FPXHPOSG-01
Содержание FP-XH Series
Страница 2: ... MEMO 2 WUME FPXHPOSG 01 ...
Страница 18: ... MEMO 1 10 WUME FPXHPOSG 01 ...
Страница 30: ... MEMO 3 8 WUME FPXHPOSG 01 ...
Страница 51: ...4 4 Reading Elapsed Values WUME FPXHPOSG 01 4 21 ...
Страница 52: ... MEMO 4 22 WUME FPXHPOSG 01 ...
Страница 88: ... MEMO 5 36 WUME FPXHPOSG 01 ...
Страница 94: ... MEMO 6 6 WUME FPXHPOSG 01 ...
Страница 140: ... MEMO 9 8 WUME FPXHPOSG 01 ...
Страница 193: ... MEMO WUME FPXHPOSG 01 ...
Страница 194: ...Panasonic Industrial Devices SUNX Co Ltd 2020 October 2020 WUME FPXHPOSG 01 ...