EN
EN
- 15 -
EN
EN
Initializing all settings
• This section explains how to revert all tool
settings to their default values at the time of
shipment from the factory.
• The error display will be turned off.
1. Set the tool to setting configuration mode.
(See page 1.)
. Press the C button.
• The control panel will begin flashing.
Display: The letter “F” flashes on and off.
Battery indication lamp: The upper and
lower bars of the battery flash on and off.
See the illustration
17
3. Press the OK button to accept the select-
ed setting.
• The control panel will stop flashing and
light up.
Default settings (Original/Factory settings)
• Speed adjustment function
→ GA1: 80 GA2: 75 GA3: 45
• Auto downshift function → 0
• Cross thread reduction function → R0
• Rundown error detecting function → 0
• Maintenance interval alarm function
→ 0
• Radio signal range limitation function
→ C0
• Buzzer setting → b0
• LED light setting → L1
• Speed control setting → P0
Checking tool settings
• When the tool stops, the current setting
value will be displayed for approximately
seconds.
• The setting status cannot be checked while
the tool panel is off. Depress the trigger
switch once to turn on the panel.
Checking the status of the speed
adjustment and buzzer settings
1. Press the A button.
• The RPM and buzzer setting values will
be displayed (in that order).
Example: If the RPM is set to 500 min
-1
and the buzzer is set to sound at the
green indicator,
“50” → “b1”
Checking the status of the LED light
and rundown error detecting func-
tion and speed control function set
-
tings
1. Press the B button.
• The LED light and tightening time and
speed control setting will be displayed
(in that order).
Example: If the LED light mode is set to
L1 and the tightening time is set to 0
and speed control is set to ON,
“L1” → “20” → P0
Checking the status of the radio sig-
nal range limitation function and
maintenance interval alarm function
settings
1. Press the C button.
• The range limitation function and num-
ber of tightening operations settings
will be displayed along with the current
count value (in that order).
NOTE:
• If you depress the switch while a setting
is being displayed, the control panel will
revert to the speed adjustment setting
display.
Checking the tool circuits and the
status of the cross thread reduction
function and auto downshift func-
tion settings
1. Press the D button.
• The tool circuits and cross thread reduc-
tion function and auto downshift function
settings will be displayed (in that order).
Example: “H3” → “R1” → “10”
Display
Tool circuit
H1
EYFGA1
H
EYFGA
H3
EYFGA3
NOTE:
• When other tools are in the area which
are not set, they may accidentally
receive a signal when setting the tool
by remote control.
Set the tool in another room if possible
or keep a fair distance to avoid this situ-
ation.