background image

2

Contents

1. 

Safety precaution ·······································································

3

2. 

Part Description ·········································································

4

3. 

Mounting ·····················································································

6

3-1 Mounting of the sensor ·························································· 6
3-2 Mounting interval ··································································· 7

4. 

I/O Circuit Diagram ··································································13

5. 

Stability Indicator ·····································································14

6. 

Beam alignment ·······································································14

7. 

Option ·······················································································15

7-1 Slit Mask (optional) ······························································ 15
7-2 Sensor mounting bracket (optional) ····································· 15

8. 

Specifications ···········································································16

8-1 Standard-beam type ···························································· 16
8-2 Narrow-beam type ······························································· 18

9. 

Dimentions ···············································································19

[email protected]

www.digiparts.ch

Ihr Schweizer Industriepartner

Содержание EX-10 Series

Страница 1: ...2013 10 http panasonic net id pidsx global Amplifier Built in Ultra slim Photoelectric sensor EX 10 Series USER S MANUAL WUME EX10 4 info digiparts ch www digiparts ch Ihr Schweizer Industriepartner ...

Страница 2: ...interval 7 4 I O Circuit Diagram 13 5 Stability Indicator 14 6 Beam alignment 14 7 Option 15 7 1 Slit Mask optional 15 7 2 Sensor mounting bracket optional 15 8 Specifications 16 8 1 Standard beam type 16 8 2 Narrow beam type 18 9 Dimentions 19 info digiparts ch www digiparts ch Ihr Schweizer Industriepartner ...

Страница 3: ...rcible bend or pulling is not applied directly to the sensor cable joint Make sure to carry out wiring in the power supply off condition Take care that wrong wiring will damage the sensor Verify that the supply voltage variation is within the rating If power is supplied from a commercial switching regulator ensure that the frame ground F G terminal of the power supply is connected to an actual gro...

Страница 4: ...itting part Emitter Receiver Beam receiving part Operation indicator Orange Stability indicator Green Mounting hole Emitter Mounting hole Beam emitting part Operation indicator Orange Stability indicator Green Beam receiving part Mounting hole Receiver Beam receiving part Beam emitting part Mounting hole Operation indicator Orange Stability indicator Green info digiparts ch www digiparts ch Ihr Sc...

Страница 5: ...X 17E Operation mode switch L Light ON D Dark ON Operation mode switch Operation indicator Orange Light up when the output is ON Operation mode switch Operation indicator Orange Emitter Receiver Mounting hole Beam receiving part Beam emitting part Mounting hole Stability indicator Green Operation indicator Orange Emitter Receiver Mounting hole Mounting hole Beam emitting part Beam receiving part S...

Страница 6: ...ting plate 2 5 or less Flat washers accessory Nuts accessory Spring washers accessory Front sensing Sensing direction M2 screw length 8 accessory Side sensing Thickness of mounting plate 2 or less Flat washers accessory Nuts accessory Spring washers accessory Sensing direction Material SPCC Uni chrome plated Two M2 length 4 mm pan head screws Accessory Material SPCC Uni chrome plated Two M2 length...

Страница 7: ...l for EX 11E EX 15E In case using at sensing distance L2 150mm the operation point ℓ2 is approx 15mm according to dia gram above The installation interval is Approx 15mm 2 approx 30mm Thus install approx 30mm or more away Thru beam type EX 11E EX 15E parallel deviation diagram typical ℓ2 200 0 150 100 50 L2 Thru beam type EX 11 EX 15 parallel deviation diagram typical 100 ℓ1 50 0 50 100 200 0 150 ...

Страница 8: ...50mm 2 approx 100mm Thus install approx 100mm or more away EX 13E EX 17E approx 100mm or more EX 13E EX 17E approx 100mm or more 500mm Emitter Receiver Thru beam type EX 13 EX 17 parallel deviation diagram typical 100 50 0 50 100 ℓ3 L3 0 800 400 600 200 Thru beam type EX 13E EX 17E parallel deviation diagram typical 100 50 0 50 100 ℓ4 L4 0 800 400 600 200 Sensing distance L mm Center Left Right Op...

Страница 9: ...ceiver EX 19 approx 257 2mm or more 1m EX 19 approx 257 2mm or more Thru beam type EX 19E parallel deviation diagram typical ℓ6 L6 200 100 0 100 200 0 1 0 5 Sensing distance L m Center Left Right Operating point ℓ mm Installation interval for EX 19E In case using at sensing distance L6 1m the operation point ℓ6 is approx 71 1mm according to diagram above The installation interval is Approx 71 1mm ...

Страница 10: ...iver EX 11S approx 21 6mm or more 150mm EX 11S approx 21 6mm or more Thru beam type EX 11SE parallel deviation diagram typical 50 25 0 25 50 200 0 150 100 50 L8 ℓ8 Center Left Right Operating point ℓ mm Sensing distance L mm Installation interval for EX 11SE In case using at sensing distance L8 150mm the operation point ℓ8 is approx 6 2mm according to diagram above The installation interval is App...

Страница 11: ...r EX 13S approx 74 2mm or more 500mm EX 13S approx 74 2mm or more Thru beam type EX 13SE parallel deviation diagram typical L10 ℓ10 100 50 0 50 100 800 0 600 400 200 Center Left Right Operating point ℓ mm Sensing distance L mm Installation interval for EX 13SE In case using at sensing distance L10 500mm the operation point ℓ10 is approx 29 2mm according to diagram above The installation interval i...

Страница 12: ...terval for EX 19S In case using at sensing distance L11 1m the operation point ℓ11 is approx 65 4mm according to diagram above The installation interval is Approx 65 4mm 2 approx 130 8mm Thus install approx 130 8 or more away Emitter Receiver EX 19S approx 130 8mm or more 1m EX 19S approx 130 8mm or more info digiparts ch www digiparts ch Ihr Schweizer Industriepartner ...

Страница 13: ... DC 10 Color code Note The thru beam type sensor emitter does not incorporate the output Load 50mA max 12 to 24V DC 10 Brown V Color code Sensor circuit Black Output Blue 0V Users circuit Internal circuit Note The thru beam type sensor emitter does not incorporate the output Brown V Color code Sensor circuit Black Output Blue 0V Users circuit Internal circuit info digiparts ch www digiparts ch Ihr...

Страница 14: ...et the emitter at the center of this range Note 1 2 Similarly adjust for up down left and right angular movement of the emitter 3 Further perform the angular adjustment for the receiver also 4 Check that the stability indicator green lights up Note 2 Note1 When using the narrow beam type EX 1 S if the beam axes are out of alignment check to see if the emitter and the receiver are facing each other...

Страница 15: ...ion Sensor mounting bracket MS EX10 1 For front sensing tipe Thru beam tipe needs 2 sets Material SPCC Uni chrome plated Two M2 length 4mm pan head screw are aattched MS EX10 2 For Side sensing tipe Thru beam tipe needs 2 sets Material SPCC Uni chrome plated Two M2 length 8mm pan head screw are aattched MS EX10 3 L form mouting bracket Thru beam tipe needs 2 sets Material SPCC Uni chrome plated Tw...

Страница 16: ...r 10mA or less Receiver 10mA or less 13mA or less Output NPN output type NPN open collector transistor Maximum sink current 50mA Applied voltage 30 V DC or less between output and 0V Residual voltage 2V or less at 50mA sink current 1V or less at 16mA sink current PNP output type PNP open collector transistor Maximum source current 50mA Applied voltage 30 V DC or less between output and V Residual ...

Страница 17: ...k current 100 mA Applied voltage 30V DC or less between output and 0 V Residual voltage 2V or less at 100mA sink current 1V or less at 16mA sink current Short circuit protection Incorporated Response time 0 5ms or less Protection IP67 IEC Ambient temperature 25 to 55 C No dew condensation or icing allowed Storage 30 to 70 C Ambient humidity 35 to 85 RH Storage 35 to 85 RH Emitting element Red LED ...

Страница 18: ...onse time 0 5 ms or less Protection IP67 IEC Ambient temperature 25 to 55 C No dew condensation or icing allowed Storage 30 to 70 C Ambient humidity 35 to 85 RH Storage 35 to 85 RH Emitting element Red LED Peak emission wavelength 650nm modulated Material Enclosure Polyalylate Lens Polyalylate Cable Note 4 0 1mm2 3 core thru beam type emitter 2 core cabtyre cable 2 m long Weight Net weight Emitter...

Страница 19: ... Emitter 6 5 5 5 6 5 2 ø2 2 mounting holes ø2 5 cable 2m long Beam emitting part Beam receiving part 2 ø2 2 mounting holes ø2 5 cable 2m long 10 1 75 1 75 4 11 14 5 4 5 6 5 2 25 4 5 4 2 Unit mm 4 5 2 25 10 6 45 1 75 1 75 1 5 4 11 14 5 4 5 6 5 Emitter Receiver 4 2 2 ø2 2 mounting holes ø2 5 cable 2m long Beam emitting part Beam receiving part 2 ø2 2 mounting holes ø2 5 cable 2m long info digiparts ...

Страница 20: ...ver Unit mm ø2 5 cable ø3 8 cable 2m long 2 ø2 2 mounting holes Beam emitting part Beam receiving part 2 ø2 2 mounting holes 2 1 3 5 10 5 5 1 75 1 75 11 14 5 4 4 5 10 6 45 5 5 1 75 1 75 1 5 14 5 11 4 3 5 2 1 7 1 8 15 2 19 2 38 500 4 5 info digiparts ch www digiparts ch Ihr Schweizer Industriepartner ...

Страница 21: ...iver Unit mm 10 4 5 2 25 14 5 1 75 1 75 4 5 11 4 5 2 25 500 4 2 4 2 4 5 14 5 1 5 4 11 1 75 10 6 45 1 75 7 1 15 2 19 2 38 2 ø2 2 mounting holes Beam emitting part 2 ø2 2 mounting holes ø3 8 cable 2m long ø2 5 cable Beam receiving part 8 info digiparts ch www digiparts ch Ihr Schweizer Industriepartner ...

Страница 22: ...ctive EX 14 Unit mm 13 6 45 2 75 1 75 1 75 14 5 4 5 1 5 8 3 5 2 1 5 11 4 5 Beam receiving part Beam emitting part 2 ø2 2 mounting holes ø2 5 cable 2m long info digiparts ch www digiparts ch Ihr Schweizer Industriepartner ...

Страница 23: ...e It cannot be used for narrow beam type Unit mm 4 M2 0 4 thru hole threads t1 2 10 8 11 2 6 5 15 7 1 4 8 3 2 10 5 t1 2 6 25 7 6 20 3 2 1 4 8 15 11 8 3 5 t1 2 7 6 3 7 20 6 5 8 3 5 15 8 11 2 ø3 4 mounting holes Unit mm Unit mm 4 M2 0 4 thru hole threads 2 M2 0 4 thru hole threads info digiparts ch www digiparts ch Ihr Schweizer Industriepartner ...

Страница 24: ...t cannot be used for narrow beam type t1 2 3 7 8 1 20 11 6 5 8 3 5 1 4 3 2 8 15 1 4 3 2 Unit mm Unit mm Unit mm t1 2 3 7 8 1 20 11 1 4 3 2 8 15 3 2 1 4 3 5 8 6 5 2 11 t1 2 10 8 1 4 7 3 2 15 8 1 4 3 2 10 5 4 M2 0 4 thru hole threads 2 M2 0 4 thru hole threads 4 M2 0 4 thru hole threads info digiparts ch www digiparts ch Ihr Schweizer Industriepartner ...

Страница 25: ...1 1 Ushiyama cho Kasugai shi Aichi 486 0901 Japan Phone 81 568 33 7861 FAX 81 568 33 8591 About our sale network please visit our website Panasonic Industrial Devices SUNX Co Ltd 2013 WUME EX10 4 October 2013 PRINTED IN JAPAN info digiparts ch www digiparts ch Ihr Schweizer Industriepartner ...