background image

M/R

SYS.

DIA.

Pulse

/min

1

Digital Blood Pressure Monitor

Operating Instructions

Thank you for purchasing our products.

Please read these in structions carefully before using

this product, and save this manual for future use.

Version: NO.01.1

Issued date: March 2023

Model NO. 

EW-BU18W011

Содержание EW-BU18W011

Страница 1: ...essure Monitor Operating Instructions Thank you for purchasing our products Please read these in structions carefully before using this product and save this manual for future use Version NO 01 1 Issu...

Страница 2: ...27 Product name Digital Blood Pressure Monitor Model EW BU18W011 Structure and composition It is composed of a main unit and a cuff Scope of application This product can measure diastolic blood press...

Страница 3: ...your arm put it on the table with the palm up and nails against the table Align the height of the cuff to the heart Keep your feet on the ground side by side When the height of the cuff cannot be ali...

Страница 4: ...ty Precautions and use this device correctly The accompanying batteries are for test run They are used to confirm the function of the device at the time of purchase and their service life will be shor...

Страница 5: ...flow in the arm should consult a doctor before using this instrument Failure to do so may result in deterioration of physical condition When you feel any abnormality in use please stop using it immedi...

Страница 6: ...ctor s advice Please do not use it for purpose other than blood pressure measurement Otherwise it may cause an accident or malfunction If the device needs to be repaired for various reasons please con...

Страница 7: ...ices around such as TV computer mobile phone There may be a risk when the air cuff is in the state of persistent hyperinflation causing discomfort such as blood stasis or paralysis in the arm If such...

Страница 8: ...ssory Structure and composition The product is composed of a main unit and a cuff Please confirm the product Note All diagrams in this specification are for EW BU18W011 Cuff socket Display Bottom Batt...

Страница 9: ...Irregular pulse warning Irregular pulse that can be detected during the measurement Memory mark When the measured value is stored this mark will flash Systolic blood pressure Indicates the systolic bl...

Страница 10: ...new batteries of the same type must be used and all 4 batteries shall be replaced at the same time Please use the batteries within the expiration date Failure to comply with the above matters may res...

Страница 11: ...onment and posture Please refer to P3 How to take a proper measurement Measuring time The blood pressure is constantly changing throughout the day Therefore take the period with the least movement aft...

Страница 12: ...ecation Measure in a room with stable temperature and in a non anxious and calm state take five deep breaths and relax for 4 5 mins before measurement As the blood pressure is affected by various cond...

Страница 13: ...Do not roll up the shirtsleeve The blood vessels in the arm will be under pressure and no proper measurement can be taken Do not wrap the cuff too loose The pressure of the cuff cannot be transmitted...

Страница 14: ...esults of the left and right arms may vary to different extent due to different conditions of each user Therefore please measure with the same arm every time 1 Wrap the cuff on your arm 2 Wrapping pos...

Страница 15: ...astener If it is wrapped too loose the cuff will swell and inflate and the blood vessel will be locally tightened which will cause an indication error and the measured value will tend to rise slightly...

Страница 16: ...zation value is more than 280 mmHg the cuff will automatically exhaust Example under inflation during measurement End of measurement Pulse is detected and mark flashes Display the measured value Flash...

Страница 17: ...econds to switch measuring methods of mmHg and kPa It is mmHg by factory setting If kPa is selected it will also be converted into mmHg during voice broadcast 1 kPa 7 5 mmHg The measured value can be...

Страница 18: ...measured value 2 Press the button again for more than 5 seconds until the measured value disappears 3 Press the button at the end 2 Press the button again to display the previous measured value M R M...

Страница 19: ...ning and the mark will flash and then it will light up after flashing for about 6 seconds When a large abnormal movement is detected for the measured value in the measurement U12 and will be displayed...

Страница 20: ...ge or a normal range If it is within the hypertension range the measured value will flash Compared with the first measurement the second measurement is more stable and the blood pressure will also dro...

Страница 21: ...out of the cuff socket 2 Store the cuff Place the tube into the cuff Please do not stretch or bend the tube with force and do not roll the tube around the main unit Otherwise it will cause malfunctio...

Страница 22: ...ation failure 1 Cleaning of main unit Visually confirm the appearance of the main unit If there is dirt for cleaning please turn off the power supply and gently wipe it with cloth that is soaked in so...

Страница 23: ...t measured at home because of nervousness or uneasiness When the blood pressure measured at home is higher than that in the hospital please pay attention to the following items Whether the cuff is pro...

Страница 24: ...measure After the warning with the mark the hand or wrist position is corrected but the measured value is too high The warning is only a reference prompt for measuring whether the posture is correct o...

Страница 25: ...r more than one second Irregular pulse during measurement P19 No function of irregular pulse warning There may be movements in the body After the measurement when flashes and a re measurement is taken...

Страница 26: ...ts etc and measure again The pulse cannot be detected correctly The mark flashes several times or does not flash at all Not inflate or inflate but failed to measure properly Is the cuff wrapped correc...

Страница 27: ...for operation Atmospheric pressure for transportation and storage Measurable circumference of upper arm Weight of the main unit Dimensions main unit Protection against electric shock Safety classifica...

Страница 28: ...specified temperature and humidity range the specified performance specifications may not be met Product specifications are subject to change without further notice Panasonic Appliances China Co Ltd...

Отзывы: