87
Installation Manual
18. MAINTENANCE & CLEANING
Perform the following maintenance annually or more often if the site
requires it to ensure proper operation.
• Clean this inverter, during the cool time of the day, whenever it is visibly
dirty.
• Before cleaning this inverter, make sure to turn off all the breakers (AC,
battery and PV).
• Ensure all connectors of this inverter are clean.
• Periodically inspect the system to make sure that all wires and
supports are securely fastened in place.
19. SERVICE
Wiring Diagram
The following diagram shows how the distribution box is electrically
connected to the hybrid inverter. When replacing breakers or wires on
the distribution box the following rules must be observed: (1) All AC
breakers must be sized for 40A or less, and (2) All wiring must be sized
for 40A or more.
NOTES:
EverVolt has L1 and L2 connections for two AC input sources,
although it can only accept one source at a time. The inverter has
separate neutral connections for grid input, generator input and output.
These are electrically common. The distribution box is both an input
conduit box and an AC load center. The distribution box also contains
maintenance transfer switches (load selection breaker). Maintenance
transfer switching assemblies allows for the inverter to be taken offline
if necessary without shutting the entire system down. These assemblies
include an interlock mechanism that isolates the AC Lines from each
other.
Maintenance, Cleaning & Service
CAUTION:
There are no user-replaceable parts inside the
inverter. Do not attempt to service the unit yourself.
Содержание EverVolt Standard EVAC-105-4
Страница 1: ...V 01012021 Installation Service Manual FOR AC AND DC COUPLED EVERVOLT SYSTEMS...
Страница 65: ...65 Installation Manual Operation and Display Panel...
Страница 76: ...76 Installation Manual Configuring the Hardware PV INPUT IS ONLY USED FOR EVERVOLT DC COUPLED SYSTEM...
Страница 83: ...83 Installation Manual Step 5 Install the Generator wire...