Others

• Make sure to use the DC power supply insulated by an

isolation transformer, etc. for this product.

If an auto-transformer, etc. (single winding transformer)

is used, this product or the power supply may be

damaged due to short-circuit.

• Make sure that the power supply is off while wiring and

inspection.

Otherwise, there is a danger of accident, electric shock or

malfunction.

• Do not use during the initial transient time (0.5 sec.) after

the power supply is switched on.

• Verify that the supply voltage variation is within the rating.

• If the power supply is switched on immediately after

being switched off, fault output may be generated. After

the power supply is switched off, wait at least 1 sec.

before switching it on again.

• If power is supplied from a commercial switching

regulator, ensure that the frame ground (F.G.) terminal of

the power supply is connected to an actual ground.

• In case a surge is generated in the used power supply,

connect a surge absorber to the supply and absorb the

surge.

• Do not run the wires together with high-voltage lines or

power lines or put them in the same raceway. This can

cause malfunction due to induction.

Confirm the wiring and piping state before supplying

power or air. Wrong wiring and piping may cause

malfunction.

Use air (dry, clean air) for the fluid. Any fluid other than

air (dry, clean air) or even air containing corrosive gas

may cause an accident or malfunction.

• Do not use air that contains foreign particles, e.g. carbon

dust, dust, water or oil. 

Since these substances may cause electric shock or 

malfunction, take appropriate countermeasures, e.g. 

install an airfilter, air-drier, etc.

• Do not use this product for any purpose other than

charge removal.

• Do not cover the ionized air outlets of the nozzles. Ozone

may build up and operating problems or failure may

occur. (The air monitoring function checks if the pressure

of air supplied to the unit drops, so if the ionized air

outlets of the nozzles are covered, it will not detect this

and will not cause charge removal operation to stop.)

• This product is CE-conformed under the EMC Directive.

The immunity adopted by this product should be

conformable to EN 61000-6-2. In order for such immunity

to be conformable to this standard, all wires connected to

this product should be limited in length to less than 10 m

32.808 ft

.

• When this product is no longer usable or required,

dispose of properly as industrial waste.

• Always be sure that the power supply and the

air supply are both turned off before inspection 

and cleaning.

Be sure to turn off the air before removing the

nozzles for purposes such as maintenance.

Air pressure may cause the discharge needles 

to fly out.

PRECAUTIONS FOR PROPER USE

• Since the removal discharge effect will deteriorate if

dirt is stuck to the tip of the discharge needle, clean the

discharge needle periodically.

• The maintenance required depends on the environment

of use. As a reference, the maintenance should be done

once in two weeks.

• The discharge needle is a part having a product life time.

It is recommended that the needle should be replaced, as

a reference, after 10,000 hours in use. When replacing it,

replace the whole unit (

ER-VWANT

).

Cleaning procedure and discharge needle replacement procedure

1

 Check that the power is turned off.

2

 Check that no air is being supplied.

3

 Turn the nozzle 

counterclockwise to remove it.

4

 Replace the discharge needle 

unit, or use a cotton swab 

moistened in alcohol to clean the 

discharge needle and the area 

around it. 

For the needle discharge unit while running it along the 

guide at the side of the opening.

5

 After cleaning, turn the nozzle clockwise to install it. 

Securely tighten the nozzle by hand until it is touching 

the enclosure, and check that the nozzle does not move. 

If the nozzle is not installed correctly, it will adversely 

affect charge removal performance and the nozzle may 

also fall out.

ER-VW

Discharge

needle unit

ER-VWANT

Nozzle

Do not use this product beyond its rated specifications.

Doing so can cause product breakdown, non-function,

or damage. Furthermore, it will also cause a marked

reduction in product life.

• Never disassemble, repair, modify, or misuse this

product, as this can cause an accident or malfunction.

Do not throw this product into fire: it may explode or

generate poisonous gas.

• Since this product emits ozone into the atmosphere,

circulate air to prevent foul smells.

If ozone lingers for long periods, metals, etc. may oxidize /

decay. Furthermore, do not try to confirm that foul smells

are caused by the ozone by drawing your face near the

nozzle outlet and air outlet: you may hurt your nose,

throat, etc.

• Do not use this product in steamy or dusty places, in

places where water and oil splash, or where spatter flies

when welding.

Содержание ER-VW

Страница 1: ...2022 7 High frequency AC Method The contents of this catalog are as of October 2017 For the latest information please visit our company website Thin Type Ionizer ER VW ...

Страница 2: ...ct up to a maximum of 5 ER VW units The air supply part is connected via quick connection joints and the power supply and input output signals can also be connected easily using connection cables with connectors at both ends Multiple ER VW units can be connected together to provide charge removal layouts that suit the target equipment End connector Accessory Cable with connector Accessory Air supp...

Страница 3: ...jacent production lines MOUNTING SIZE Comparison of air consumption Notes 1 Minimum width dimensions after nozzle angle adjustment 2 Maximum width dimensions after nozzle angle adjustment ER VW Previous spot type Minimum 100 ℓ min ANR to Maximum 300 ℓ min ANR Air consumption ℓ min ANR 300 200 100 0 Minimum 15 ℓ min ANR Maximum 60 ℓ min ANR to In contrast to previous low frequency types and DC type...

Страница 4: ...arge Air supply Discharge halt Ionizer main unit One each of connector attached cable length 0 5 m 1 640 ft end connector and lead wire for connecting F G are supplied with the ionizer main unit Type Appearance Charge removal time 1 000 V 100 V Ion balance Model No Spot type 1 sec or less Note 1 10 V or less Note 1 ER VW Note 2 Notes 1 A typical sample applied with a supply voltage of 24 V a dista...

Страница 5: ...tput and 0 V Residual voltage 1 V or less at 50 mA sink current Output operation Check output CHECK ON when the discharge needle is dirty or worn OFF when operation is normal Error output ERROR OFF when abnormal discharge is detected ON when operation is normal Discharge output DSC Note 5 ON when discharging OFF when discharge halts Short circuit protection Incorporated Discharge halt input DSC OF...

Страница 6: ...harge plate monitor At center of CPM Air flow Correlation between charge removal distance and ion balance Correlation between charge removal distance and charge removal time Charge removal field 0 50 MPa Connector terminal arrangement Power I O connector Joint connector 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 1 Non voltage contact or NPN open collector transistor or Discharge halt input Low 0 V Discharg...

Страница 7: ...ins 1 and 3 of the end connector 9 pin to the lead wire for connecting the F G If the ground is not connected correctly operating problems or accidents may occur so be sure to check the usage conditions and connect the ground in such a way that the power supply does not become shorted Nozzle M4 pan head screw Purchase separately Adjusting the air blowing direction After screw down the nozzle to lo...

Страница 8: ...o this product should be limited in length to less than 10 m 32 808 ft When this product is no longer usable or required dispose of properly as industrial waste Always be sure that the power supply and the air supply are both turned off before inspection and cleaning Be sure to turn off the air before removing the nozzles for purposes such as maintenance Air pressure may cause the discharge needle...

Страница 9: ...3 ø4 5 ø0 177 mounting holes 16 3 0 642 2 0 079 16 9 0 665 4 8 0 189 40 1 575 110 4 331 80 3 150 7 0 276 60 2 362 15 3 0 602 127 5 000 Plug with hexagonal hole Joint for ø6 mm ø0 236 in air tube 42 1 654 2 ø14 4 ø0 567 DIMENSIONS Unit mm in The CAD data can be downloaded from our website ...

Страница 10: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent rights of a third party Printed in Japan Industrial Device Business Division 7 1 1 Morofuku Daito shi Osaka 574 0044 Japan industrial panasonic com ac e ⓒ Panasonic Industry Co Ltd Specifications are ...

Отзывы:

Похожие инструкции для ER-VW