198
EQ-500
SPECIFICATIONS
Type
0.2 to 2.5 m
0.656 to 8.202 ft
0.1 to 2.5 m
0.328 to 8.202 ft
0.2 to 1.0 m
0.656 to 3.281 ft
0.1 to 1.0 m
0.328 to 3.281 ft
0.2 to 2.5 m
0.656 to 8.202 ft
0.1 to 2.5 m
0.328 to 8.202 ft
0.2 to 1.0 m
0.656 to 3.281 ft
0.1 to 1.0 m
0.328 to 3.281 ft
10 % or less of operation distance
EQ-501
EQ-511
EQ-502
EQ-512
EQ-501T
EQ-511T
EQ-502T
EQ-512T
Multi-voltage
DC-voltage
Adjustable range (Note 1) (Note 2)
Sensing range (at maximum setting distance) (Note 2)
Hysteresis
With timer
With timer
With timer
With timer
Model No.
Item
Supply voltage
Power / Current consumption
Output
Output operation
Short-circuit protection
Response time
Operation indicator
Stability indicator
Distance adjuster
Sensing mode
Timer function
Automatic interference prevention function
Emitting element
Receiving element
Material
Connection method
Cable
Cable length
Weight
Accessory
Protection
Ambient temperature
Ambient humidity
Ambient illuminance
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Environmental resistance
24 to 240 V AC
10 % or 12 to 240 V DC
10 %
Ripple P-P 10 % or less
12 to 24 V DC
10 % Ripple P-P 10 % or less
AC: 4 VA or less
DC: 3 W or less
AC: 5 VA or less
DC: 4 W or less
AC: 4 VA or less
DC: 3 W or less
AC: 5 VA or less
DC: 4 W or less
45 mA or less
Switchable either Detection-ON or Detection-OFF
Relay contact 1a
•
Switching capacity: 250 V AC 3 A (resistive load)
30 V DC 3 A (resistive load)
•
Electrical life: 100,000 or more switching operations
(switching frequency 1,200 operations/hour)
•
Mechanical life: 50 million or more switching operations
(switching frequency 18,000 operations/hour)
NPN open-collector transistor
•
Maximum sink current: 100 mA
•
Applied voltage: 30 V DC or less (between output and 0 V)
•
Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
PNP open-collector transistor
•
Maximum source current: 100 mA
•
Applied voltage: 30 V DC or less (between output and
V)
•
Residual voltage: 1 V or less (at 100 mA source current)
0.4 V or less (at 16 mA source current)
20 ms or less (For
EQ-50
T
depends on the setting timer period) 2 ms or less (For
EQ-51
T
depends on the setting timer period)
Orange LED (lights up when the output is ON)
Green LED (lights up under stable operating condition)
2-turn mechanical adjuster with indicator
Incorporated (Note 3)
IP67 (IEC)
20 to
55
C
4 to
131
F
(No dew condensation or icing allowed), Storage:
30 to
70
C
22 to
158
F
35 to 85 % RH, Storage: 35 to 85 % RH
Sunlight: 10,000
?
x at the light-receiving face, Incandescent light: 3,000
?
x at the light-receiving face
2,000 V AC for one min. among supply terminals, non-supply metal parts and relay contact output terminals, 1,000 V AC for one min. between relay contacts
100 M , or more, with 500 V DC megger among supply terminals, non-supply metal parts and relay contact output terminals as well as between relay contacts
10 to 55 Hz frequency, 1.5 mm
0.059 in
amplitude in X, Y and Z directions for two hours each
500 m/s
2
acceleration (50 G approx.) in X, Y and Z directions for three times each
Infrared LED (modulated)
2-segment photodiode
Enclosure: ABS, Front cover: Polycarbonate, Display cover: Polycarbonate
Screw-on terminal connection
Suitable for round cable
"
9 to
"
11 mm
"
0.354 to
"
0.433 in
Extension up to total 100 m
328.084 ft
is possible with 0.3 mm
2
, or more, cabtyre cable
Incorporated
Switchable either BGS or FGS function
100 g approx.
85 g approx.
Adjusting screwdriver: 1 pc.
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
Incorporated
with variable
(0.1 to 5 sec.)
ON-delay /
OFF-delay timer
The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m
0.328 ft
, or more, away.
The adjustable range and the sensing range are specified for white non-glossy paper (200
200 mm
7.874
7.874 in
) as the object.
Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure
to check the operation with the actual sensing object. Refer to ‘
Automatic interference function
’ (p.8) of ‘
PRECAUTIONS FOR PROPER USE
’ for
details.
Notes: 1)
2)
3)