background image

196

EQ-500

BGS / FGS FUNCTIONS MAKE EVEN THE MOST CHALLENGING SETTINGS POSSIBLE!

The BGS function is best suited for the following case

Background not present

When object and background are
separated

BGS (Background suppression) function

The sensor judges that an object is present when light is received at position A of
the light-receiving element (2-segment element). This is useful if the object and
background are far apart. Not affected if the background color changes or
someone passes behind the conveyor.

Setting distance

Background

Light received at 
element A

Element A

Object

Moving object

in the back

Element B

ON

OFF

Light received at element 
B or light not received 

The FGS function is best suited for the following case

Background present

When object and background are close
together
When the object is glossy or uneven

FGS (Foreground suppression) function

The sensor judges that no object is present when light is received at position B of
the light receiving element (2-segment element)(The conveyor is detected). This
function is useful if the object and the background are close together or if the
object is glossy or uneven. However, sensing is impossible if there is no
background (conveyor, etc.)..

Conveyor

Conveyor

Conveyor

Light received 
at element A

Light is not received at 
element B, so an object 
is judged to be present

Light received at element B

Element A

Lens

Emitting 
element

For glossy

object

Object present

Object absent

OFF in this condition only

ON in all other conditions

ON

ON

OFF

Element B

Setting 
distance

A conveyor or other 
background must be present.

Содержание EQ-500 Series

Страница 1: ...Due to its advanced optical system the sensor is not affected by variations in the object s angle or gloss compared to conventional sensors Moreover as the difference in sensing range between black and white varies by only approx 5 Note sensing can be performed at a somewhat constant distance even if the sensing object is black or white EQ50 Introducing the new DC voltage type equipped with BGS FG...

Страница 2: ...n of the passage of packages on a conveyor belt Can accurately detect packages even if they vary in size and color Little affected by contamination on lens Level check within the hopper Even if the lens surface gets somewhat dirty from dust particles there is very little change in the operation field rendering stable and consistent detection even for objects appearing close to the front surface of...

Страница 3: ...tion is best suited for the following case Background present When object and background are close together When the object is glossy or uneven FGS Foreground suppression function The sensor judges that no object is present when light is received at position B of the light receiving element 2 segment element The conveyor is detected This function is useful if the object and the background are clos...

Страница 4: ...put Timer function EQ 501 24 to 240 V AC 10 or 12 to 240 V DC 10 Relay contact 1a EQ 501T ON delay OFF delay timer Timer period 0 1 to 5 sec ON delay OFF delay timer Timer period 0 1 to 5 sec ON delay OFF delay timer Timer period 0 1 to 5 sec ON delay OFF delay timer Timer period 0 1 to 5 sec EQ 502 EQ 502T EQ 511 12 to 24 V DC 10 NPN open collector transistor PNP open collector transistor Equippe...

Страница 5: ...current 20 ms or less For EQ 50 T depends on the setting timer period 2 ms or less For EQ 51 T depends on the setting timer period Orange LED lights up when the output is ON Green LED lights up under stable operating condition 2 turn mechanical adjuster with indicator Incorporated Note 3 IP67 IEC 20 to 55 C 4 to 131 F No dew condensation or icing allowed Storage 30 to 70 C 22 to 158 F 35 to 85 RH ...

Страница 6: ...00 3 937 150 5 906 200 7 874 1 3 281 2 5 8 202 2 6 562 Setting distance 2 5 m 8 202 ft Setting distance L m ft Setting distance L m ft These bars indicate the sensing range with the respective objects when the distance adjuster is set to a sensing range of 2 5 m 8 202 ft 1 m 3 281 ft long respectively with white non glossy paper 2 5 m 8 202 ft 1 m 3 281 ft White non glossy paper Left Right Center ...

Страница 7: ...unstable Sensing object Tilt Interference prevented area L mm in or more L mm in or more L mm in or more 1 3 281 2 6 562 3 9 843 0 60 2 362 20 0 787 80 3 15 40 1 575 Mounting interval L mm in Setting distance m ft Setting distance m ft Mounting interval L mm in 1 3 281 2 6 562 3 9 843 0 150 5 906 250 9 843 50 1 969 200 7 874 100 3 937 Interference prevented area This product is not a safety sensor...

Страница 8: ...between 9 to 11 mm 0 354 to 0 433 in with a smooth covering material that allows the attached conduit connector to be securely tightened the tightening torque of the screw should be of 1 5 to 2 0 N m Verify that the supply voltage variation is within the rating If power is supplied from a commercial switching regulator ensure that the frame ground F G terminal of the power supply is connected to a...

Страница 9: ...d in an environment containing inflammable or explosive gases Never disassemble or modify the sensor Multi voltage type DC voltage type BGS select Distance adjustment Description Distance adjuster Turn the distance adjuster fully counterclockwise to the minimum sensing range position 0 2 m 0 656 ft approx Optimum position 1 Please an object at the required distance from the sensor gradually turn t...

Страница 10: ...ote 2 ON delay timer adjuster Note 2 Stability indicator Green Operation mode switch Note 1 Distance adjuster 2 turn Adjuster indicator Operation indicator Orange Beam receiving part Center of beam emitting Center of sensing 3 M5 nut seats on both sides 3 5 1 0 201 mounting holes 58 2 283 58 2 283 5 0 197 Center of beam emitting Center of sensing 2 M5 length 30 1 181 screws t 2 t 0 079 4 0 157 10 ...

Отзывы: