background image

Applicant: Matsushita Electric Works, Ltd.               Transmitter Type: HHV20021106 

Emergency Portable Cellular Telephone 

 
 

2.3. Self Test Mode 

When the unit is in Power Down mode, press and hold TEST button for one second.  Then, the PHONE starts 

Self-Test for the following three items (GPS Module, AMPS RSSI, Battery). 
 

2.3.1. Indication by using TEST LED (Flashing/Solid) 

 

2.3.1.1. GPS Module Test 

This test checks whether receive circuit of GPS module operates properly and checks whether Communication 

between MAIN CPU and GPS module is made properly. 

If an error is detected, the status becomes flashing TEST LED (Green). 

 

2.3.1.2. AMPS RSSI Test 

This test is to check whether RSSI (Received Signal Strength Indicator) is at a reasonable level and check 

whether it is possible to detect Control Channel so that Phone can become SERVICE status. 

If the status remains “No Service” and cannot become SERVICE status, TEST LED (Green) becomes flashing. 

When the communication with GPS module is normal and that PHONE was able to become SERVICE status, 

TEST LED (Green) becomes SOLID and proceed to Battery Test. 
 
It takes about 8 to 10 seconds to complete these two tests 

 

2.3.2. Indication by using BATTERY LED (Flashing/Solid) 

2.3.2.1. Battery Condition Test 

This test checks whether battery level is at useable level or at low-battery level so that battery replacement is 

necessary. 

When battery level is at Low level and battery replacement is required, BATTERY LED (Green) becomes flashing. 

When battery level is at an acceptable level, BATTERY LED (Green) becomes SOLID state. 
 
When TEST button is pressed under this state, unit is turned off and the mode becomes Power Down mode. 

Otherwise the unit will be turned off automatically after 10 seconds, then enter to Power Down Mode. 

 

2.3.3. Siren Test 

When the unit is in Power Down mode, press and hold TEST button for four seconds. The phone sounds siren. 

A siren will be stopped when a user press TEST button again or 5 minutes elapsed. 

 

ECG2111

 

- 6 - 

Содержание ECG2111

Страница 1: ...Applicant Matsushita Electric Works Ltd Transmitter Type HHV20021106 Emergency Portable Cellular Telephone ECG2111 Operating Instructions Draft Version 1 0 November 20 2001 ...

Страница 2: ...aluations of the relevant scientific literature Over 120 scientists engineers and physicians from universities government health agencies and industry reviewed the available body of research to develop the ANSI Standard C95 1 The design of your phone complies with the FCC guidelines in addition to those standards ANTENNA CARE Use only the supplied or an approved antenna Unauthorized antennas modif...

Страница 3: ...itiating a Call 4 2 2 2 Establishing Position 4 2 2 3 Voice Conversation 5 2 2 4 Emergency Response Center ERC 5 2 3 SELF TEST MODE 6 2 3 1 Indication by using TEST LED Flashing Solid 6 2 3 1 1 GPS Module Test 6 2 3 1 2 AMPS RSSI Test 6 2 3 2 Indication by using BATTERY LED Flashing Solid 6 2 3 2 1 Battery Condition Test 6 2 3 3 Siren Test 6 3 GENERAL SPECIFICATIONS 7 4 NOTICE FOR USING EMERGENCY ...

Страница 4: ...elected cellular traffic channel Once the latitude and longitude data is sent received the ERC will have the option to open up the cellular traffic channel for voice use via a speakerphone arrangement in the terminal device allowing the user to converse with personnel at the ERC 1 1 Features GPS based location technology Built in High sensitivity GPS receiver Voice speakerphone backup capability A...

Страница 5: ...Indicates the AMPS RSSI Signal is too weak or No Service Solid Green Indicates the GPS module communication is OK And Indicates the AMPS RSSI Signal is acceptable and the control channel was detected 5 BATTERY Indicator This LED indicates the Battery status Flashing Green Indicates the Battery status is low Solid Green Indicates the Battery status is acceptable 6 Speakerphone Even in case the loca...

Страница 6: ...olding VMS button for 1 second will initiate an emergency calling process 2 2 2 Establishing Position The unit incorporates a built in Global Positioning System GPS receiver The GPS receiver is used to establish the position of the user in latitude and longitude format After obtained the location the unit will place a call to the Emergency Response Center ERC utilizing a pre programmed stored area...

Страница 7: ...erse with the ERC personnel without having the device up to their ear The speakerphone would be optionally switched in to the cellular traffic channel by the ERC immediately after the ESN MIN and latitude longitude information was sent and acknowledged 2 2 4 Emergency Response Center ERC The Emergency Response Center ERC consists of emergency call response personnel and links to local emergency re...

Страница 8: ...ICE status TEST LED Green becomes flashing When the communication with GPS module is normal and that PHONE was able to become SERVICE status TEST LED Green becomes SOLID and proceed to Battery Test It takes about 8 to 10 seconds to complete these two tests 2 3 2 Indication by using BATTERY LED Flashing Solid 2 3 2 1 Battery Condition Test This test checks whether battery level is at useable level ...

Страница 9: ... to 893 970 MHz Number of RF Channels 832 Channels Full Duplex Channel Spacing 30 KHz Duplex Spacing 45 MHz Frequency Stability within 2 5PPM RF Power Output Max 0 6 W AMPS and GPS Operating Temperature 0 to 50 degree Celsius Battery Primary Lithium Ion CR123A x 2 Supply Voltage 6 V DC nominal Dimensions W x H x D 49mm x 131 5mm x 34 5mm Weight Approx 160 g Subject to change without notice ECG2111...

Страница 10: ...G Emergency Portable Cellular Telephone This unit has a hands free function Hold it in your hand away from your ear or use it while it is still on your waist It can also be used while it is on a desk Loud sounds are sometimes emitted from the speakerphone of this unit Never use it while holding it against your ear ECG2111 8 ...

Отзывы: