![Panasonic EBX70 - CELL PHONE Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/panasonic/ebx70-cell-phone/ebx70-cell-phone_service-manual_261923054.webp)
CALIBRATION PROCEDURES
Issue 1
Section 9
PMCD030901C8
Revision 0
– 52 –
Service Manual
9.2.2
Power Level Tables
The following tables show the measurement limits according to power level:
The values in these tables are required only if manual Tx Trim is used to trim individual channels.
EGSM 900
GSM 1800
GSM 1900
Power Level
(PL)
Output Power (dBm)
Nominal
Target
Min
Max
5
32.25
32.0
32.5
6
31.0
30.5
31.5
7
29.0
28.5
29.5
8
27
26.5
27.5
9
25
24.5
25.5
10
23
22.5
23.5
11
21
20.5
21.5
12
19
18.5
19.5
13
17
16.5
17.5
14
15
14.5
15.5
15
13
12.5
13.5
16
11
10.5
11.5
17
9
8.5
9.5
18
7
6.5
7.5
19
5
4.5
5.5
Power Level
(PL)
Output Power (dBm)
Nominal
Target
Min
Max
0
29.55
29.3
29.8
1
28.0
27.5
28.5
2
26.0
25.5
26.5
3
24.0
23.5
24.5
4
22.0
21.5
22.5
5
20.0
19.5
20.5
6
18.0
17.5
18.5
7
16.0
15.5
16.5
8
14.0
13.5
14.5
9
12.0
11.5
12.5
10
10.0
9.5
10.5
11
8.0
7.5
8.5
12
6.0
5.5
6.5
13
4.0
3.5
4.5
14
2.0
1.5
2.5
15
0.0
-0.5
0.5
Power Level
(PL)
Output Power (dBm)
Nominal
Target
Min
Max
0
29.25
29.0
29.5
1
28.0
27.5
28.5
2
26.0
25.5
26.5
3
24.0
23.5
24.5
4
22.0
21.5
22.5
5
20.0
19.5
20.5
6
18.0
17.5
18.5
7
16.0
15.5
16.5
8
14.0
13.5
14.5
9
12.0
11.5
12.5
10
10.0
9.5
10.5
11
8.0
7.5
8.5
12
6.0
5.5
6.5
13
4.0
3.5
4.5
14
2.0
1.5
2.5
15
0.0
-0.5
0.5