![Panasonic EBX70 - CELL PHONE Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/panasonic/ebx70-cell-phone/ebx70-cell-phone_service-manual_261923049.webp)
FAULT FINDING
PMCD030901C8
Section 8
Issue 1
Service Manual
– 47 –
Revision 0
The output measured at the coupler (U607) output should be ~20 dB below the power amplifier output:
Figure 8.3: GSM 1800 / GSM 1900 Coupler (U607)
Signal level at the RFIN connection of the Automatic Power Controller (APC) IC (U605):
Figure 8.4: APC IC (U605)
dBm
12
2
-8
-18
-28
-38
Coupler O/P, single-ended measurement
Start: 1.709200 GHz
Stop: 1.711200 GHz
1
10742-1
dBm
5
-15
-35
-55
-75
-95
APC I/P, single-ended measurement.
Start: 1.709200 GHz
Stop: 1.711200 GHz
1