– 7–4 –
7.4. Test Equipment Setup
7.4.1. Equipment Required
Figure 7.5. : Test Connection Diagram
IMPORTANT NOTE
To allow accurate measurement of the complete unit the test equipment must be connected as shown,
For testing the handheld unit the following equipment is required:
1. PCB Repair Jig
2. RF Adaptor
3. RF Cable
4. 12 V power supply
5. Personal computer with RS232 interface and running Microsoft Windows
®
95, 98, NT, XP or 2000
6. Data Cable
7. GSM test station
8. G60 Service software
The G60 Service software should be installed onto the main drive of the personal computer.
The RF cable is connected to the GSM test station via suitable adaptor. The 3.8 V supply is connected
to the RF Adptor and PCB Repair Jig.
NOTE: A suitable test SIM card compatible with the GSM test station will be required.
PCB TEST SETUP
COMPLETE UNIT TEST SETUP
T5 Screwdriver (Part No. )
This screwdriver is required to remove the case screws from the phone.
Data Cable
RF Cable
PC
RF
Adaptor
GSM Tester
Handset
3.8 V DC
Power Supply
Data Cable
RF Cable
PC
PCB
GSM Tester
PCB
Repair Jig
3.8 V DC
Power Supply
Calibration Software
This is the test software for the telephone unit and should be installed onto the personal computer to be used for testing.