![Panasonic EBG60 - CELL PHONE Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/panasonic/ebg60-cell-phone/ebg60-cell-phone_service-manual_261915051.webp)
– 7–3 –
RF Adaptor (Part No. PVRFJIG)
The RF Adaptor provides the connections bettween the test equipment and the phone for unit testing.
Figure 7.2. : RF Adaptor
Figure 7.3. : Data Cable
A cable with SMA female connector is provided to make the RF connection. An SMA to N-Type male adaptor will be
required to connect the Jig to the service equipment. Cable losses for the RF connection are 0.5 dBM (GSM 900)
and 0.8 dBM (GSM 1800).
GSM Tester
This unit acts as a base station providing all the necessary GSM signalling requirements and also provides GSM
signal measuring facilities.
Data Cable (Part No. 73PV150001W)
RF Cable (Part No. JT00084)
The data cable for used to software download and calibration.
Case Separation Tool (Part No. JT00059)
The case Separation Tool is used to facilitate separation of the front cover and case.
Figure 7.4. : Case Separation Tool
The RF cable provides the necessary connections between the PCB Repair Jig/RF Adapter and external test equipment.