100
DX-600/800
APR 2002
Edition 1.0
4.3.4.
Information Code: 416
START
END
Is communication with the
reference unit successful?
Change Function Parameter
#011: Reduce Rx Sensitivity
Level
Yes
No
Yes
No
Change Function Parameter
#023: Increase Training
Check Period
Does the problem still occur?
1. Replace the MJR PCB.
2. Replace the SC PCB.
Refer to Sect. 4.6.
Does the problem still occur?
Change Function Parameter
#013: Increase G3 Rx
Equalization
Does the problem still occur?
END
Does the problem still occur?
Yes
No
No
Yes
No
Yes
Check the telephone line
condition.