background image

1. Remove the trim ring by pulling down the mounting 
    springs. (Squeeze mounting spring and pull down 
    carefully.) (Fig. 10)

2. Clean the trim ring. (Don’t put into hot water. 
    Use non-abrasive kitchen detergent, wipe dry with 
    clean cloth.) (Fig. 11)

Fig. 11

Gloves

Trim ring

Fig. 10

Trim ring

2-Mounting
springs

Gloves

Ceiling

Fig. 9

2-Mounting

springs

Trim ring 

2-Slots

13. Insert the mounting springs into the slot as 
      shown in the figure and attach the trim ring 
      to the fan body. (Fig. 9) 

Do not immerse motor in water when cleaning.

Do not soak resin parts in water over 140

 °

F (60

 °

C).

7

INSTALLATION (BETWEEN JOISTS MOUNTING) CONTINUED 

MAINTENANCE (CLEANING)

CAUTION

WARNING

Disconnect power source before working on 
unit. Routine maintenance must be done 
every year.

Never use gasoline, benzene, thinner or any other 
such chemicals for cleaning the ventilating fan.

4. Remove dust and dirt from fan body using a vacuum 
    cleaner. (Fig. 12)

3. Dry the trim ring after cleaning.

6. Replace the trim ring. (Fig. 9) 

5. Using a cloth dampened with kitchen detergent, 
    remove any dirt from fan body. Wipe dry with clean 
    cloth. (Fig. 13)

Fig. 12

Fig. 13

Gloves

Vacuum
cleaner

Disconnect power source before working on unit.

This is a GU24 type lamp base and the lamp is fragile and heavy. Please handle with care.

Make sure the temperature of lens and lighting unit has cooled down before maintenance 
(cleaning) or replacement of lamp.

MAINTENANCE (REPLACEMENT OF LED LAMP)

WARNING

1. Remove the trim ring by pulling down mounting springs. 
    (Squeeze mounting spring and pull down carefully.) 
    (Fig. 10)

4. Replace the trim ring. (Fig. 9) 

 

2. Remove the LED lamp. (Fig. 14) 

 

3. Replace the 11 W BR30 shape LED lamp (model

:

    11BR30G4DIM

/

927

/

GU24, from the company

    Green Creative). (Fig. 8 of page 6) 
 

Fig. 14

LED lamp  

1

2

Содержание DV-08VRE2

Страница 1: ... maintain the product after the installation and this booklet should be presented to users Please retain this booklet for future reference INSTALLATION INSTRUCTIONS Ventilating Fan 2 3 3 4 5 7 4 4 4 5 7 7 BACK COVER BACK COVER BACK COVER BACK COVER COMPATIBLE DIMMERS NOT SUPPLIED GENERAL SAFETY INFORMATION DESCRIPTION CONTENTS UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM INSTALLATION B...

Страница 2: ...ire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities To reduce the risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions The following symbol word panels are used to classify and describe the level of hazard inj...

Страница 3: ...ving lighting device that uses one 11 W BR30 shape LED lamp model 11BR30G4DIM 927 GU24 from the company Green Creative and produces almost the same illumination as a standard 65 W incandescent lamp It also incorporates a thermal cut off for safety The trim ring is a spring loaded quick remove type A damper for preventing air counterflow is provided The blower uses a high capacity sirocco fan devel...

Страница 4: ... interference received including interference that may cause undesired operation This product may be used with optional dimmer switch in accordance with dimmer switch instruction instructions Risk of Fire Type IC Inherently Protected Only Use LED Lamp Max 11W Type GU24 DESCRIPTION CONTINUED UNPACKING 4 Trim ring Fan body Adaptor Fan Blower unit Motor LED lamp Junction box Suspension bracket Damper...

Страница 5: ...Insert the suspension brackets into the fan body from each side of the bracket cover Fig 1 If spacing A between center joists is 12 inches cut all suspension brackets along the two C cuts with a hacksaw or other tools Before After 2 C cuts UP Ceiling Suspension bracket Joist Joist Fan body Fig 2 Suspension bracket 1 8 3 2 About 3 8 9 5 Long hole Unit inches mm 4 Long screws ST4 2X20 joists Fig 3 4...

Страница 6: ...duit Neutral to white Live to black Live to black Earth ground to green Fig 5 Wire nut CAUTION Mount junction box cover carefully so that lead wires are not pinched 9 Mount back the junction box cover 10 Install a circular duct and secure it with clamps or wire ties and seal it with mastic or approved foil tape A 4 or 6 inch circular duct is needed to connect to the relevant part of adaptor Fig 6 ...

Страница 7: ...nzene thinner or any other such chemicals for cleaning the ventilating fan 4 Remove dust and dirt from fan body using a vacuum cleaner Fig 12 3 Dry the trim ring after cleaning 6 Replace the trim ring Fig 9 5 Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with clean cloth Fig 13 Fig 12 Fig 13 Gloves Vacuum cleaner Disconnect power source before working on unit...

Страница 8: ...e of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing ducts may not achieve their rated air flow mastic or approved foil faced tape Model No Exhaust Air direction Voltage V Noise at 0 1 WG sones Speed...

Отзывы: