9
MENU SETTING MODE
The mode will change to RUN mode when the mode selection key is held
down during this setting process. In doing so, changed items before holding
down the mode selection key have been set.
Note: 1) In case connecting pressure range 1MPa type of pressure sensor head to Japanese model controller,
only “MPa” or “kPa” can be set. Also, in case connecting 3.5MPa or more type, setting item for unit
change is not displayed.
2) in case of connecting pressure range 3.5MPa type of sensor head to out side of japan type controller.
“
” is not displayed.
Setting Item
Factory setting
Description
Comparative
output 1 output
mode setting
Sets comparative output 1 output mode.
Comparative
output 2 output
mode setting
Sets comparative output 2 output mode.
N.O. / N.C.
selection
Sets when Nomal Open (N.O.) or Normal Close (N.C.).
Initial state of excepting OFF of the comparative output 2 setting is “
.”
Analogue voltage
/ current output
selection
Selects Analogue voltage output or analogue current output.
Function setting
Sets Auto-reference function or remote zero-adjustment function and current
value hold function or peak / bottom 2 function.
Response time
setting
Sets response time.
The response time can be select from 5ms, 10ms, 25ms, 50ms, 100ms,
250ms, 500ms, 1,000ms or 5,000ms.
Display color
selection of the
main display
Selects display coler of main display.
Unit selection
Selects pressure unit.
RUN mode
EASY mode
Hysteresis
mode
Press for 2 sec.
Window com-
parator mode
<Comparative output 2 output mode setting>
EASY mode
Hysteresis
mode
Window
comparator
mode
OFF mode
<N.O. / N.C. selection> (When the comparative output 2 output mode setting is set to OFF)
N.C.
N.O.
<N.O. / N.C. selection> (When the comparative output 2 output mode setting is set to other than OFF)
Output 1: N.O.
Output 2: N.O.
Output 1: N.C.
Output 2: N.C.
Output 1: N.O.
Output 2: N.C.
Output 1: N.C.
Output 2: N.O.
<Analogue voltage / current output selection>
Analogue
voltage
output mode
Analogue
current out-
put mode
<Function setting>
OFF
Auto-reference
function mode
Remote zero-
adjustment
function mode
Current
value hold
function
Auto-peak /
bottom hold
2 function
<Response time setting>
10ms
5ms
5,000ms
<Display color selection of the main display>
Red when ON
Green when OFF
Green when ON
Red when OFF
Always red
Always green
<Unit selection> (Note 1)
kPa (Note 2)
MPa
bar
kgf/cm
2
psi
<RUN mode>
<Comparative output 1 output mode setting>
7
SETTING WHEN TURNING ON THE POWER
After turning ON the power, set pressure range of pressure sensor head con-
nected to this product. The set pressure range is memorized and the range is
displayed every time after tuning on the power. Then, move to RUN mode.
In case replacing sensor head or resetting it, set the pressure range again.
8
RUN MODE
Setting the threshold value
Refer to
<Comparative output 1 / 2 output mode setting>
in “
MENU
SETTING MODE
” for setting conditions.
The Sub display conducts the threshold value. Main display does not changed.
Notes: 1) If the set pressure range is exceeded, “
” (exceeds the upper limit) or “
” (exceeds the lower
limit) will appear on the sub display. “
” will also appear if the Hi side threshold value exceeds the
Lo side threshold value when setting the “hysteresis mode / window comparator mode” threshold value.
2) Auto-reference value and remote zero-adjustment value are displayed.
For details, refer to “
AUTO-REFERENCE FUNCTION
” and “
REMOTE ZERO-ADJUSTMENT
FUNCTION.
”
3) In the dash line box is not displayed when not setting “
” or “
” in external input switch. For the
setting method, refer to<Function setting> in “
MENU SETTING MODE.
”
Zero-adjustment function
The zero-adjustment function forcibly sets the pressure value to “zero” when
the pressure port is opened.
X;Z\^ _# ; `{
Key lock function
The key lock function prevents key operations so that the conditions set in
each setting mode are not inadvertently changed.
<Key lock set>
<Key lock released>
Peak / bottom hold function
The peak / bottom hold functions display the peak value and bottom value of
{
For detail, refer to “
PEAK / BOTTOM HOLD FUNCTION
.”
The peak value is displayed on the main display and the bottom value is dis-
played on the sub display.
the higher vacuum side indicates the peak value, while the lower vacuum side
indicates the bottom value.
<Peak / bottom hold set>
<Peak / bottom hold released>
-0.1 to 1MPa
0 to 50MPa
0 to 10MPa
0 to 3.5MPa
0 to 1MPa
Pressure range
setting
Turning ON the power
Check the set
pressure range
Resetting the
pressure range
|#
pressure range
RUN mode
The set pressure range is displayed.
Hold down
Automatic
Hold down
Automatic
Hold down
Automatic
Blinks alternately
Hold down
Hold down
Display is changed by pressing down.
Automatic
(Note 2)
Blinks alternately
Press down: increase threshold value to high pressure side.
Press down: decrease threshold value to low pressure side.
Comparative
output 1
EASY mode
(Comparative output 2 is OFF)
Hysteresis mode / Window
comparator mode
· Lo side
Hysteresis mode / Window
comparator mode
· Hi side
EASY mode
Comparative
output 2
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
(Note 3)
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com