INSTRUCTION MANUAL
Separate type · digital sensor controller
DPC-L100
Sereis
For liquid / gas
MJE-DPCL100 No. 0040-92V
Thank you very much for purchasing Panasonic products.
Read this Instruction Manual carefully and thoroughly for the correct and optimum
use of this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
Never use this product as a device for personnel protection.
In case of using devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
The product for use inside Japan complies with Japanese Measurement
Laws. Avoid using the product model for outside of Japan within Japan.
1
PART DESCRIPTION
Notes: 1) Attach the unit switch plate corresponds to the set pressure unit.
2) The product for use inside Japan can be set only to “MPa” or “kPa.”
2
MOUNTING
T h e s e n s o r m o u n t i n g b r a c k e t
MS-DP1-6
is available as an option.
When mounting the sensor onto the
sensor mounting bracket, etc., the tight-
ening torque should be 0.5N·m or less.
T h e p a n e l m o u n t i n g b r a c k e t
MS-DP1-2
(optional), as well as the
front cover
MS-DP1-3
(optional) are
also available.
For mounting of the panel mounting
bracket, refer to the Instruction Manual
enclosed with
MS-DP1-2
.
3
CONNECTION OF PRESSURE SENSOR HEAD
In case of initial set up or reset, select pressure range.
incase changing pressure sensor head, check pressure range.
Connection method
1.
Insert the pressure sensor head cable into the
product’s connector area for the pressure sen-
Disconnection method
1.
Pressing the release lever of the pressure sen-
sor head cable, pull out the connector.
Note: Do not pull by holding the cable without pressing the re-
lease lever, as this can cause cable break or connector
break.
<Terminal pin arrangement>
Terminal pin No.
Terminal name
1
Sensor head supply voltage
2
Analogue input
3
0V
4
Not used
4
WIRING
Connection method
1.
Insert cable with connector
into
the product’s connector area for a power / I-O
Disconnection method
1.
Pressing the release lever of the cable with con-
nector, pull out the connector.
Note: Do not pull by holding the cable without pressing the release
lever, as this can cause cable break or connector break.
<Terminal pin arrangement>
Terminal pin
No.
Terminal name
Terminal pin
No.
Terminal name
1
+V
4
Comparative output 1
2
Analogue voltage
/ current output
5
Comparative output 2
3
0V
6
External input
Connector area for a
power supply / I-O cable
Connector area for a
pressure sensor head
Output 1 operation
indicator
Lights up when com-
parative output 1 is ON
Output 2 operation
indicator
Lights up when com-
parative output 2 is ON
Mode selection key
Set value UP key
Set value
DOWN key
Attach area for
unit switch plate
(Note 1, 2)
Main display
Sub display
Release lever
Pressure
sensor
head cable
<Connector area of the pressure sensor head cable>
e-con: 1473562-4
[Tyco Electronics AMP G.K.]
Release lever
Cable with
connector
CN-66A-C
<Connector area of the cable with connector>
Housing: PAP-06V-S
[JST Mfg. Co., Ltd.]
M3 (length 6mm)
screws with washers
Accessory with
MS-DP1-6
Sensor mounting bracket
MS-DP1-6
(Optional)
6
5
I/O CIRCUIT DIAGRAMS
NPN output type
PNP output type
!"# $
2) Take care that when the analogue current is output, 5V or more voltage generates.
3) When using the analogue voltage output, be careful to the input impedance of the connected device.
Furthermore, note that if the cable is extended, the cable resistance will cause the voltage to drop.
6
OUTPUT MODE AND OUTPUT OPERATION
The EASY mode, hysteresis mode or window comparator mode can be se-
lected as the output mode for comparative output 1 and comparative output
2. Refer to <
Comparative output 1 / 2 output mode setting
> in “
MENU
SETTING MODE
” for details.
EASY mode
ON / OFF of the comparative output is controlled in this mode.
%& $'
Refer to <
> in “
PRO MODE
” for setting.
2)
“
” is displayed for comparative output 1 and “
” for comparative output 2 on the sub-display.
Hysteresis mode
The comparative output ON / OFF state can be controlled with randomly set
hysteresis in this mode.
Notes: 1) “
” or “
” is displayed for comparative output 1 and “
” or “
” is displayed for com-
parative output 2 on the sub display.
Window comparator mode
In this mode, the ON or OFF state of the comparative output is controlled with
a pressure in the set range.
%& $'
Refer to <
> in “
PRO MODE” for setting.”
2)
“
” or “
” is displayed for comparative output 1 and “
” or “
” is displayed for com-
parative output 2 on the sub display.
* 8; = %&$; #
*1
Non-voltage contact, NPN transistor or
DC 2-wire output
High (5 to 30V DC or Open): Invalid
Low (0.4V DC or less): valid
or
*2
Non-voltage contact, PNP transistor or
DC 2-wire output
High (5 to +V DC or Open): valid
Low (0.6V DC or less): Invalid
or
Pressure
P
0
ON
OFF
Comparative
output
H (Hysteresis)
%%&$@
Pressure
Hi
Lo
ON
OFF
H (Hysteresis)
H: 1 digit or more
When using psi unit model for out-
side of Japan, it is 2 digits or more.
However, the 50MPa pressure
range model is 20 digits or more.
Comparative
output
Hi
Lo
ON
OFF
%%&$@
Pressure
Comparative
output
H (Hysteresis)
H (Hysteresis)
(Gray) Analogue
voltage / current
output (Note 1, 2, 3)
(Brown) +V
(Black) Comparative output 1
(White) Comparative output 2
(Pink) External input
(Blue) 0V
12 to 24V DC
±10%
+
-
Load
Load
(*1)
Main circuit
(Brown) +V
(Pink) External input
(Black) Comparative output 1
(White) Comparative output 2
(Gray) Analogue
voltage / current
output (Note 1, 2, 3)
(Blue) 0V
Load
Load
(*2)
Main circuit
12 to 24V DC
±10%
+
-