194
DP-2330/3030
MAR 2005
Ver.2.1
DP-2310/3010
15
Not Used
16
Side Adjust (ADU)
Adjustment of LSU side-side (ADU).
-8 - +7
0.5mm
17
Charge Roller Voltage
Charge voltage compensation adjustment.
-76 - +76
2.60V
18
Standard Laser Power
Laser power compensation adjustment.
-29 - +25
19
Std Bias DC Voltage
Adjustment of bias standard voltage.
-77 - 76
3.92V
20
Not Used
21
TDC Gain Voltage
Adjustment of toner density sensor gain
voltage.
-86 - +40
0.033V
22-24 Not Used
25
Bias Duty Ratio
(Factory use only)
Bias duty ratio adjustment
-5 - +5
0.80%
26
TDC Judgment Level
Adjustment of toner supply starting judgement
voltage level.
-26 - +26
19.5mV
27
Bias Frequency
(Factory use only)
AC Bias frequency adjustment
-5 - +3
28
QUANTUM White Density
Adjustment of standard white density level.
-99 - +99
29
QUANTUM Black Density
Adjustment of standard black density level.
-99 - +99
30
Light Halftone Adj.
Halftone duty ratio adjustment
-127 - +127
31
Fuser Temperature
Adjustment of fuser temperature.
-15 - +15
0.833
°
C
32
Fuser Edge Temperature
Temperature compensation for edges
-15 - +15
0.833
°
C
33
TDC Max. Read Only
Set by Digital QUANTUM (QUARC) control
-99 - +99
(Read only)
34
TDC Min. Read Only
Set by Digital QUANTUM (QUARC) control
-99 - +99
(Read only)
35
TDC Avg. Read Only
Set by Digital QUANTUM (QUARC) control
-99 - +99
(Read only)
36
Paper Loop (Tray 1)
Individual Fine Adjustment for Tray 1
-99 - +99
37
Not Used
38
ID Standard Voltage
Adjustment of judgement standard voltage.
-35 - +35
39
LSU Unit PWM Adjust
Adjustment of PWM value of LSU.
-32 - +32
40
Transfer Current Side 1
Adjustment of Transfer Current.
-16 - +15
0.6uA
41
Paper Loop (Bypass)
Individual Fine Adjustment for Sheet Bypass
-99 - +99
42
Paper Loop (Tray 2)
Individual Fine Adjustment for Tray 2
-99 - +99
43
Paper Loop (2-Sided)
Adjustment for the length of the loop formed
before the copier timing roller.
-99 - +99
44
FAX Laser Duty Adj
Printer Density Adjustment for FAX.
(-) : Darker.
(+) : Lighter.
-99 - +99
45
Not Used
46
PRINTER Laser Duty Adj
Printer Density Adjustment for Printer.
(-) : Darker.
(+) : Lighter.
-99 - +99
F6 Mode
No.
Item
Remarks
Setting
Range
Содержание DP-2330
Страница 4: ...4 Beispiel DP 2330 3030 Hinweis ...
Страница 8: ...8 memo ...
Страница 35: ...35 DP 2330 3030 MAR 2005 Ver 2 1 DP 2310 3010 1 6 Control Panel DP 2310 3010 DP 2330 3030 ...
Страница 70: ...70 DP 2330 3030 MAR 2005 Ver 2 1 DP 2310 3010 23 Remove 3 Screws 19 24 Remove the Motor Bracket 908 ...
Страница 454: ...memo ...
Страница 455: ...88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3 DZSD001829 9 ...
Страница 470: ...memo ...
Страница 471: ...Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3 DZSD000965 14 ...
Страница 482: ...Local Firmware Update Tool Parallel USB Port 5b4 Firmware Code File selection is completed Click Next Page 12 ...
Страница 486: ...DZZSM00270 ...