48
10.2. Caution for Replacing Parts
10.2.1.
Notice after replacing RAM/Digital P.C.B. Module
[TM AV1] is displayed, after replacing Digital P.C.B. or RAM/Digital P.C.B. Module.
Once power off, and start up again.
10.2.2.
Items that should be done after replacing parts
*Note1:
*Note2: (except DMR-EZ49VEB)
*Note3:
PG Shifter Automatic Adjustment Procedure
Resetting object
Condition of power
Short Terminal
IC6001
POWER ON
TL6004 (Reset L) and TL6002 (GND)