29
HDD READ SEEK
Inspection
Inspecting seek time of HDD to inspect per-
formance.
At start
The [*] sign is added every approx. 10
seconds while inspecting.
Two digits on the right side are the
progress level of the inspection (The
unit is %).
Example on the way of inspection:
When HDD is OK after inspection:
(NG is displayed when error is
excluding o)
(Transfer rate is calculated from the
AV scanning result, and when it is
less than 35Mbps, NG is displayed.)
$: [X] is displayed when seek time is
over 270msec., there is error or trans-
fer rate is NG.
Position at $ is space when excluding
those.
##: Number of data of over 100msec.
and less than 270msec.
When it is over 100, [99] is displayed.
When the number is less than 5, we
judge it normal.
Press [3] [1] in service mode.
* When canceling the inspection
mode while executing, do “forced
power-off”.
Method:
Press [POWER] key on the main
unit more than 4 seconds.
Item
LCD display
Key operation
Mode name
Description
(Remote controller key)
Содержание DMR-BS750EG
Страница 5: ...5 2 2 Precaution of Laser Diode ...
Страница 8: ...8 3 2 Service Information 3 3 Caution for DivX ...
Страница 15: ...15 4 Specifications ...
Страница 16: ...16 ...
Страница 17: ...17 ...
Страница 18: ...18 5 Location of Controls and Components ...
Страница 19: ...19 ...
Страница 49: ...49 9 2 6 Grease ...
Страница 50: ...50 9 2 7 How to Clean the Lens of Optical Pick UP Follow the 9 2 1 Upper Base Ass y ...
Страница 53: ...53 10 1 2 Checking and Repairing of BD Drive ...
Страница 54: ...54 10 1 3 Checking and Repairing of AV IO P C B ...
Страница 55: ...55 10 1 4 Checking and Repairing of HDD ...
Страница 56: ...56 10 1 5 Checking and Repairing of Digital P C B ...
Страница 71: ...S 13 ...
Страница 77: ...S 19 ...
Страница 95: ...S 37 ...
Страница 133: ...S 75 S8 4 Packing Parts and Accessories Section A1 1 PC2 PC3 A1 A2 A5 PC1 PC4 A3 A4 BATTERY REMOTE CONT PC5 ...