1.1.
General guidelines
1.
IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by in the
Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Pmarts List. It is essential that these critical
parts should be replaced with manufacturer’s specified parts to prevent X-RADIATION, shock, fire, or other hazards. Do not
modify the original design without permission of manufacturer.
2. An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis is not isolated from the AC
power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal
injury from electrical shocks. It will also protect AC Adaptor from being damaged by accidental shorting that may occur during
servicing.
3. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
4. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
5. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.1.1.
Leakage current cold check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed metal-
lic cabinet part on the equipment such as screwheads,
connectors, control shafts, etc. When the exposed metal-
lic part has a return path to the chassis, the reading
should be between 1M
Ω
and 5.2M
Ω
.
When the exposed metal does not have a return path to
the chassis, the reading must be .
1.1.2.
Leakage current hot check
(See Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5k
Ω
, 10 watts resistor, in parallel with a
0.15
μ
F capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensi-
tivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt-
age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliampere. In case a mea-
surement is outside of the limits specified, there is a pos-
sibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the cus-
tomer.
Содержание DMP-B500EB
Страница 4: ...4 1 2 Caution for AC cord only for B500EB ...
Страница 12: ...12 4 1 Others Licenses ...
Страница 13: ...13 5 Location of Controls and Components ...
Страница 14: ...14 ...
Страница 24: ...24 9 Disassembly and Assembly Instructions 9 1 Disassembly Flow Chart ...
Страница 25: ...25 9 2 P C B location ...
Страница 31: ...31 Lighting ass y including LCD SW P C B lighting sheet B lighting sheet A ...
Страница 34: ...34 10 1 2 Checking and Repairing of Main P C B 2 ...
Страница 54: ...54 15 1 2 Packing Accessories Section PC4 PC2 PC5 PC3 A2 A5 A1 A8 A7 PC1 A3 A4 A4 1 A5 A6 B500EG B500EB ...