27
5. Release LCD cable, pull out the P57002(FFC), and then
remove the bottom cabinet.
NOTE:
When remove the LCD cable, pull out the LCD cable
straight in the direction of the arrow.
9.4.
TRV Unit
NOTE:
The countermeasure against static electricity is necessary
when servicing the surrounding of traverse unit.
Moreover, the traverse unit is the precision optical part.
Take care not to touch surrounding of the lens and not to
shock to the traverse unit.
1. Pull out the P55001(FFC) and P55010(FFC) and
P55011(FFC), and then remove the TRV unit.
NOTE:
When remove the FFC, pull up the locking tab in the
direction of the arrow(1), and then remove the FFC in
the direction of the arrow (2).
NOTE:
While fixing the
FFC, push the FFC by its retainer
plate instead of pressing it directly which may cause
the wire bent.
9.5.
Remote Control P.C.B.
1. Pull out the P57001(FFC), and then remove the remote
control P.C.B..