35
10 Measurements and Adjustments
10.1. Introduction
When servicing this unit, make sure to perform the adjustments necessary based on the part (s) replaced.
Before disassembling the unit, it is recommended to back up the camera data stored in Flash-ROM as a data file.
NOTE: (When replacing the Lens unit, Master Flange Unit and MOS FPC Unit)
• When the MOS FPC unit is unavoidably removed for Lens unit, Master Flange unit and MOS FPC unit replaced, an optical tilt
adjustment is necessary after parts are exchanged.
• The adjustment software (DSC_Tilt) is necessary to execute an optical tilt adjustment.
• The adjustment software “DSC_Tilt” is available at “TSN Website”.
NOTE: (When replacing the Main P.C.B.)
• Number of necessary adjustment items decreases by copying the backup data to new Main P.C.B. when adjustment data in old
Main P.C.B. can be read by ROM_BACKUP “DSC
→
SD” in “10.2.2. Flash-ROM Data Backup”.
For more details, please refer an item “Main P.C.B. (to which the backup data was copied)” in the table of “10.3.2. Adjustment
Specifications”.
10.2. Before Disassembling the unit
10.2.1. Initial Setting Release
The cameras specification are initially set in accordance with model suffix (such as EB/EG/GK/GC and so on.).
Unless the initial setting is not released, an automatic alignment software in the camera is not able to be executed when the align-
ment is carried out.
Note:
The initial setting should be again done after completing the alignment. Otherwise, the camera may not work properly.
Therefore as a warning, the camera display a warning symbol “ ! ” on the LCD monitor every time the camera is turned off.
Refer to the procedure described in “3.5.2. INITIAL SETTINGS” for details.
[ How to Release the camera initial setting ]
Preparation:
• Attach the Battery.
(Since this unit has built-in memory, it can be performed without inserting memory card.)
1. Turn the Power on.
2. Press the [ MODE ] button, and select the [ NORMAL PICTURE ] mode by Cursor buttons, then press the [ MENU/SET ] but-
ton.
3. Turn the Power off.
(If the unit is other than [ NORMAL PICTURE ] mode, it does not display the initial settings menu.)
Step 1. The temporary cancellation of “INITIAL SETTINGS”:
While pressing “[ UP ] of Cursor button” and [ MOTION PICTURE ] button simultaneously, turn the Power on.
Step 2. Cancellation of “INITIAL SETTINGS”:
Press the [ PLAYBACK ] button in order to enter the [ PLAYBACK ] mode.
Press “[ UP ] of Cursor button” and [ MOTION PICTURE ] button simultaneously, turn the Power off.
The LCD displays the “ ! ” mark before the unit powers down.
Содержание DMC-SZ9EA
Страница 16: ...16 ...
Страница 19: ...19 Error Code List The error code consists of 8 bits data and it shows the following information ...
Страница 27: ...27 Fig D6 9 3 4 Removal of the LCD Unit Fig D7 Fig D8 ...
Страница 28: ...28 9 3 5 Removal of the Top Case Unit Fig D9 9 3 6 Removal of the Flash Top P C B and Mic Fig D10 Fig D11 ...
Страница 29: ...29 9 3 7 Removal of the Lens Unit W MOS Fig D12 9 3 8 Removal of the Main P C B Fig D13 ...
Страница 31: ...31 9 4 2 Removal of the Master Flange Unit ...
Страница 41: ...41 ...