34
Network Matching And Gain Control Switches
The E&M card has two sets of switches which control the set up of the card to compensate for circuit
characteristics. There are 3 groupings.
SW105 , SW205 and SW305 which control the matching characteristics of the 1st , 2nd and 3rd circuits
respectively.
SW104 , SW204 and SW304 control the transmission gain for the 1st , 2nd and 3rd circuits respectively.
SW103 , SW203 and SW303 control the reception gain for the 1st , 2nd and 3rd circuits respectively.
These switches should normally be left in their preset positions since these have been chosen to suit the UK
network.
The following figure and tables show the location and effect of these switches.
Figure 27 - Location Of Matching Switches On The E&M Card
Switches 105 to 305 have two positions A and B to match the following:
A
370+620/310 uF
B
300+1000/0.22 uF
Switches 103 to 303 and 104 to 304 are four position DIP switches which all have following settings matrix
Table 9 - E&M Card DIP Switch Settings
Warning
Switches should be left set to the OFF position. Any other setting may result in unstable cross connection and
invalidate the approval.
SW103~303 & SW104 ~ 304
1
2
3
4
Gain Set
OFF
OFF
OFF
OFF
+4 dB
ON
OFF
OFF
OFF
0 dB
OFF
ON
OFF
OFF
-2 dB
OFF
OFF
ON
OFF
-4 dB
OFF
OFF
OFF
ON
-6 dB