Before operating, please read the following "Safety Instructions" carefully.
To prevent personal injury, injury to others and property damage, the following instructions must be followed.

 

Incorrect operation caused by failure to follow instructions will cause harm or damage, the seriousness of which is 
classified as follow:

WARNING

This sign warns of 
death or serious 
injury.

CAUTION

This sign warns of 
injury to users or 
damage to property.

 

The instructions to be followed are classified by the following symbols:

  

This symbol (with a white background) denotes an 
action that is PROHIBITED.

 

This symbol (with a black background) 
denotes action that is COMPULSORY.

SAFETY PRECAUTIONS

To be followed absolutely

 

WARNING

 

If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides down during operation, please do 
not use the Electric Home Shower Unit  and contact the authorized dealer immediately to avoid a hazard to users 
such as damage to property, serious injury or death. Never fi x the ELB Reset Lever forcibly with tape, etc.

 

Do not insert fi nger or other objects into the Unit to avoiding physical and electric shock hazards.

 

Do not replace the Shower Head, Shower Hose or any other parts of the Unit with spare parts other than genuine 
parts.                                                                                                                                      

Shower Head 

Shower Hose

•  Parts for other models will not fi t to this model and may cause hazardous                

condition to user.

 

Do not spray water to the Unit, nor put wet towels on it to avoid from                                    

Safe

Pump

+

-

U-Mode

Pump

Set

1

2

3

U-Memory

JET PUMP

U-Memory 

Safe

Pump

+

-

U-Mode

Pump

Set

1

2

3

U-Memory

JET PUMP

U-Memory 

coming into contact with any live parts etc., in order to prevent smoke                               
emission, ignition, fi re and electric shock hazards.

 

Metallic / chrome hose and conductive valve shall not be used.

 

This appliance is not to be used for a potable water supply.

 

The Unit must be earthed. 

•  Improper grounding could cause electric shock.

 

Stop using the Unit when any abnormality / failure occurs and turn "OFF" the Miniature Circuit Breaker (MCB). 
(Risk of smoke / fi re / electric shock / scalding)

Example of abnormality / failure:
•  The ELB Reset Lever cannot be reset. Please refer to item no. 3. “TEST OPERATION” at page EN15.
•  Burnt odor or smoke is detected during operation.
•  The Front Plate / Back Plate is deformed or abnormally hot.
•  The outlet water temperature become extremely hot and cannot be controlled using the - and + button at Control Panel.

 

Contact your authorized dealer immediately for maintenance / repair.

 

Switch off the Miniature Circuit Breaker (MCB) before any service to avoid electric shock hazards.

 

In time of lightning / thunder, switch "OFF" the Miniature Circuit Breaker (MCB) in advance to protect the Electric 
Home Shower Unit against possible damage.

 

Inspect on the built-in ELB (once a month) to avoid a hazard to users such as damage to property, serious injury or 
death. Please refer to item no. 3. “TEST OPERATION” at page EN15.

 

Each time shower water is turned ‘ON’, check the water temperature by hand before showering.

 

When the shower is used by someone such as child, old person, sick person and physically handicapped person, 
the person responsible for their safety is kindly requested to pay attention                                     
and check the shower temperature by using hand from time to time. 

 

Pay attention to shower temperature when reducing the volume of water. 

•  The shower temperature will become very hot if the water fl ow rate is too low.

 

This appliance is not intended for use by persons (including children) with reduced physical, 
sensory or mental capabilities, or lack of experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance by a person responsible for 
their safety. Children should be supervised to ensure that they do not play with the appliance.

BEFORE USING ELECTRIC HOME SHOWER

Содержание DH-3UD1

Страница 1: ...asih kerana memilih Pancuran Mandi Elektrik Panasonic Produk ini hanya untuk kegunaan di rumah sahaja Sila baca semua arahan ini dengan teliti demi keselamatan dan penggunaan yang optimum dan simpan Panduan Penggunaan ini di tempat yang selamat untuk rujukan di masa hadapan Safe Pump U Mode Pump Set 1 2 3 U Memory JET PUMP U Memory Power Control JET PUMP Off High ELB Electric Home Shower Household...

Страница 2: ...be used for a potable water supply The Unit must be earthed Improper grounding could cause electric shock Stop using the Unit when any abnormality failure occurs and turn OFF the Miniature Circuit Breaker MCB Risk of smoke fire electric shock scalding Example of abnormality failure The ELB Reset Lever cannot be reset Please refer to item no 3 TEST OPERATION at page EN15 Burnt odor or smoke is dete...

Страница 3: ...ce must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility Please make sure the O Ring is not removed and shall be free from foreign O P E N C L O S E O Ring Filter Unit particle to avoid water leaking Press Push On Off Button before and after each shower Press the Push On Off Button only Do not pull D...

Страница 4: ...er Knob Water Volume Knob Back Plate Front Plate Parts not included Outlet Inlet ELB Reset Lever View from the bottom ELB Test Button Push On Off Button ACCESSORIES Packing Included Items Shower Head Packing Shower Head 1 set x 2 Shower Hanger Packing Shower Hose 1 set Rail Holder 2 set Shower Hanger Ass y 1 set Filter Body Packing Filter Body Assembly 1 set Rubber Packing 1 pc Filter Body Assembl...

Страница 5: ...se the function please refer to page EN7 U Memory DH 3UDP1 DH 3UD1 1 U Memory allows users to store a combination one data from function as below a U Mode function b Pump ON OFF function c Shower temperature 2 U Memory provides three different data combination that can be saved U Memory button 1 2 3 Note For how to use the function please refer to page EN8 DESCRIPTION OF LCD DISPLAY CONTROL PANEL ...

Страница 6: ...not pull the Push On Off Button press only 6 Select the preferred shower by turn the Shower Select Lever Note When stop the water flow or change water shower selection from Wide Shower to Spot Shower some water will continue to drip from Shower Head for less than 2 minutes This is normal due to some water remain in the Shower Head and no abnormality to the Unit Wide Shower Shower Select Lever Norm...

Страница 7: ... i Cool Down Mode ii Warm Up Mode iii Hot Cool b U Mode operation will start by press U Mode button at Control Panel c The U Mode function will vary by subsequently pressing the U Mode button U Mode Cool Down U Mode Warm Up U Mode Hot Cool d After select the U Mode function Hot Cool Indicator will flash approximately 3 second and selected U Mode Indicator will illuminate depending on the selected ...

Страница 8: ...y enables users to record recall and erase data up to three memories Steps To Do LCD Display Remarks U Memory Data Record Press and hold the U Memory 1 2 3 button until U Memory number flash WarmCoolHot Up DownCool Cool Safe Pump Off U Memory 1 When U Memory number illuminates data will be recorded U Memory Data Recall Press one of U Memory button 1 2 3 WarmCoolHot Up DownCool Cool Safe Pump Off U...

Страница 9: ...__ U Mode Pump Set 1 2 3 U Memory JET PUMP Wide Shower Normal Shower Spot Shower Shower Select Lever Water Volume Knob Waist Height H 35 cm 45 cm Floor Main Water Valve Water Volume Knob Push On Off Button Figure 1 Figure 2 MAINTENANCE WARNING Switch off the Miniature Circuit Breaker MCB before any service to avoid electric shock hazards 1 Main Body cleaning Be sure to switch OFF the Miniature Cir...

Страница 10: ...ure to switch On the ON OFF DP double pole Switch 4 Make sure to switch On the Miniature Circuit Breaker MCB No water flows out from the Shower Head at all 1 Check the Main Water Valve Turn On the Main Water Valve if it is closed refer HOW TO USE at page EN6 2 Check the Push On Off Button If the LCD Panel still light OFF Please do not use the Unit and contact the authorized dealer immediately Wate...

Страница 11: ...clog up Do not install remove or reinstall the Unit by yourself Improper installation will cause leakage electric shock or fire Installation and wiring must be done by competent personnel Do not share the inlet and outlet pipe of the Home Shower Unit with other outlets The pressure may drop due to water being drawn off at other point The shower temperature may become very hot CAUTION Flexible Cord...

Страница 12: ... and then unhook the top side DH 3UP1 DH 3US1 Off High Power Control ELB Front Plate Power Control Knob Lift up Screw Power Control Knob Note Power Control Knob attached to Front Plate Make sure the Power Control Knob is at Off condition Remove the Screw at the bottom of the Unit Lift up the Power Control Knob to make it free Power Control Knob is attached to VR Shaft inside the Unit Make sure the...

Страница 13: ...rd Holder Flexible Cord L 205 mm approximately Unscrew the Cord Holder and fix the Flexible Cord Strip the lead wire coating Fasten the live wire L and neutral wire N to the ELB L N and earth wire to the Ground Point with 1 N m 10 kgf cm torque Fix back the Cord Holder to its position to clamp the Flexible Cord Connect wires in correct polarity L N Main Power Board Power Supply Terminals Earth Con...

Страница 14: ...e is used for external piping connection must wait for the glue to dry before proceed to test run with water 6 How to fix the Front Plate DH 3UDP1 DH 3UD1 U Mode Pump Set 1 2 3 U Memory JET PUMP U Mode Pump Set 1 2 3 U Memory JET PUMP U Mode Pump Set 1 2 3 U Memory JET PUMP Front Plate Back Plate Press Screw Close the Front Plate of the Unit according to the sequence as illustrated Close from top ...

Страница 15: ...ighten the Upper Rail Holder with 1 screw JET PU MP Screw Upper Rail Holder Prepare the Shower Hanger and Sliding Rail remove the Shower Hanger Knob by rotating it anticlockwise then install the parts following the number and Sliding Rail Shower Hanger Shower Hanger Knob TEST OPERATION 1 Before switch ON electricity supply check the wiring Switch ON the Miniature Circuit Breaker MCB and ON OFF DP ...

Страница 16: ...i tidak boleh digunakan untuk bekalan air yang boleh diminum Unit ini mesti dibumikan Pembumian yang tidak sempurna boleh menyebabkan kejutan elektrik Jangan gunakan Unit ini sekiranya anda mendapati sebarang kerosakan atau keadaan luar biasa berlaku dan pastikan Pemutus Litar Elektrik berada dalam keadaan OFF Risiko berasap kebakaran kejutan elektrik melecur Contoh kerosakan keadaan luar biasa Tu...

Страница 17: ...idak beroperasi maka produk ini tidak boleh disambungkan kepada suis luaran seperti alat penghidup masa atau penyambungan litar yang biasanya di on dan off oleh utiliti Pastikan O Ring tidak tertanggal dan bersih daripada bendasing atau kotoran untuk O P E N C L O S E O Ring Unit Penapis mengelakkan kebocoran air Tekan Tuas On Off sebelum dan selepas mandi Tuas On Off hendaklah ditekan sahaja Jang...

Страница 18: ...ombol Isipadu Air Penutup Belakang Penutup Set Bahagian yang tidak disertakan Air Keluar Air Masuk Tuas Set Semula ELB Pandangan dari bawah Butang Ujian ELB Tuas On Off AKSESORI Set Barangan disertakan Set Kepala Pancuran Kepala Pancuran 1 set x 2 Set Penyangkut Pancuran Hos Pancuran 1 set Pemegang Batang Gelongsor 2 set Penyangkut Kepala Pancuran 1 set Set Unit Badan Penapis Unit Badan Penapis 1 ...

Страница 19: ...ketidakselesaan semasa penggunaan Nota Untuk cara menggunakan fungsi ini sila rujuk halaman MY7 U Memory DH 3UDP1 DH 3UD1 1 U Memory membolehkan pengguna menyimpan gabungan satu data daripada fungsi seperti di bawah a Fungsi U Mode b Fungsi ON OFF pam c Suhu pancuran 2 U Memory menyediakan tiga kombinasi data berbeza yang boleh disimpan butang U Memory 1 2 3 Nota Untuk cara menggunakan fungsi ini ...

Страница 20: ...f ditekan sahaja 6 Pilih pancuran mandian pilihan dengan memusingkan Tuas Pilih Pancuran Nota Apabila menghentikan pengaliran air atau menukar pemilihan pancuran air dari Pancuran Luas ke Pancuran Tompok beberapa titisan air akan terus keluar dari Kepala Pancuran kurang dari 2 minit Ini adalah biasa kerana terdapat air terting gal di dalam Kepala Pancuran dan bukan perkara luar biasa kepada Unit i...

Страница 21: ...od Cool Down ii Mod Warm Up iii Hot Cool b Operasi U Mode akan bermula dengan menekan butang U Mode pada Panel Kawalan c Fungsi U Mode akan berbeza dengan menekan secara berterusan butang U Mode U Mode Cool Down U Mode Warm Up U Mode Hot Cool d Selepas memilih fungsi U Mode Penunjuk Hot Cool akan berkelip kira kira 3 saat dan Penunjuk U Mode pilihan akan menyala bergantung pada fungsi U Mode yang ...

Страница 22: ...olehkan pengguna merekod memanggil semula dan memadam data sehingga tiga memori Langkah langkah Untuk dilakukan Paparan LCD Kenyataan Rekod data U Memory Tekan dan tahan U Memory Butang 1 2 3 sehingga nombor U Memory berkelip WarmCoolHot Up DownCool Cool Safe Pump Off U Memory 1 Apabila nombor U Memory menyala data akan direkodkan Ingat semula data U Memory Tekan satu pada butang tetapan U Memory ...

Страница 23: ...n Biasa Pancuran Tompok Tuas Pemilih Pancuran Tombol Isipadu Air Paras Pinggang H 35 cm 45 cm Lantai Injap Air Utama Tombol Isipadu Air Tuas On Off Gambarajah 1 Gambarajah 2 PENYENGGARAAN AMARAN Pastikan Pemutus Litar Elektrik MCB dimatikan sebelum penyelenggaraan untuk mengelakkan bahaya kejutan elektrik 1 Pembersihan Penutup Set Pastikan Pemutus Litar Elektrik dimatikan sebelum dibersihkan 1 Ber...

Страница 24: ...adaan asal lihat CARA CARA MENGUJI di muka surat MY15 3 Pastikan Suis ON OFF DP dwikutub dihidupkan 4 Pastikan Pemutus Litar Elektrik MCB dihidupkan Tiada air mengalir keluar dari Kepala Pancuran 1 Periksa Injap Air Utama buka Injap Air Utama sekiranya tertutup rujuk CARA CARA MENGGUNAKANNYA di muka surat MY6 2 Periksa Tuas On Off Sekiranya Panel LCD masih padam jangan gunakan Unit dan sila hubung...

Страница 25: ...gan memasang menanggalkan atau memasang semula unit dengan sendiri Pemasangan yang tidak betul akan mengakibatkan kebocoran air kejutan elektrik atau kebakaran Pemasangan dan pendawaian haruslah dilakukan oleh pekerja yang mahir Perkongsian paip untuk air masuk dan keluar adalah dilarang Tekanan air akan berkurang sekiranya terdapat air keluar pada saluran yang lain Suhu air pancuran akan menjadi ...

Страница 26: ...DH 3UP1 DH 3US1 Off High Power Control ELB Penutup Set Tombol Kawalan Kuasa Angkat ke atas Skru Tombol Kawalan Kuasa Nota Tombol Kawalan Kuasa melekat pada Penutup Set Pastikan Tombol Kawalan Kuasa dalam keadaan Off Tanggalkan skru dari bahagian bawah unit Angkat Tombol Kawalan Kuasa untuk menjadikannya bebas Tombol Kawalan Kuasa dipasang pada VR Shaft di dalam Unit Pastikan Tombol Kawalan Kuasa t...

Страница 27: ...bel dan pasangkan Kabel Fleksibel Buangkan Penyalut Wayar di bahagian hujungnya Ketatkan wayar hidup L dan wayar neutral N pada ELB L N dan wayar bumi pada Pasak Bumi dengan menggunakan daya kilas 1 N m 10 kgf cm Pasang semula Pemegang Kabel untuk memegang Kabel Fleksibel Sambungkan wayar pada kekutuban yang betul L N Papan Suis Utama Terminal Bekalan Kuasa Bumi Sambungan wayar pada arah kekutuban...

Страница 28: ...ila gam digunakan untuk sambungan paip luar mestilah tunggu gam kering sebelum ujian dengan air diteruskan 6 Menutup Penutup Set DH 3UDP1 DH 3UD1 U Mode Pump Set 1 2 3 U Memory JET PUMP U Mode Pump Set 1 2 3 U Memory JET PUMP U Mode Pump Set 1 2 3 U Memory JET PUMP Penutup Set Penutup Belakang Tekan Skru Tutupkan Penutup Set seperti susunan yang ditunjukkan pada gambarajah Tutupkan dari atas ke ba...

Страница 29: ... tetapi tidak melebihi bahagian atas Unit Ketatkan Pemegang Batang Gelongsor Atas dengan 1 skru JET PU MP Skru Pemegang Batang Gelongsor Atas Sediakan Penyangkut Pancuran dan Batang Gelongsor tanggalkan Tombol Penyangkut Pancuran dengan memusingkannya arah lawan jam kemudian pasangkan mengikut urutan and Batang Gelongsor Penyangkut Pancuran Tombol Penyangkut Pancuran CARA CARA MENGUJI 1 Periksa Pe...

Страница 30: ...sonic Manufacturing Malaysia Berhad 196501000304 No 3 Jalan Sesiku 15 2 Section 15 Shah Alam Industrial Site 40200 Shah Alam Selangor Darul Ehsan Malaysia http www panasonic com Printed in Malaysia H0622Y0 ...

Страница 31: ......

Страница 32: ...MEMO ...

Отзывы: