7
(EN)
Miscellaneous Settings
• These settings are saved in nonvolatile memory in the remote controller, so even
when its batteries
are changed, the settings do not have to be made again.
• Furthermore, making changes to these settings may cause actual operation to deviate from what is
printed in the Operating Instructions, so be sure to fully explain this to the customer.
• Do not change any settings other than those items in table below.
1. Press
,
and
at the same time for 4 seconds or longer
when the controller is stopped (displaying the current time only).
• “ ” starts blinking and the setting screen is displayed.
Setting data
Item number
2. Press
/
to select item number,
press
/
to select setting data,
and press
.
3. Press
.
Setting item
Setting data
Factory
setting
Check
1 Operation Mode
*1
2 Flap Display
3 Select Fan Speed
5 Clock Display
00: 24-hour
4 Temperature Display
00: °C
01: °F
00: °C
00: 5 levels
(Cool in 5 levels) +
Swing + Stop
00: Speed 5
(1 to 5, Auto)
6 Ventilation Fan Setting
*2
00: Off
01: On
00: Off
18 Energy Saving Setting
*2
01: On
19 ECONAVI Setting
*2
01: On
20 nanoe
TM
X Setting
*2
*1 Set to [02: / / ] or [03: / ] if you are using the unit only for cooling.
*2 Press the function setting button for 4 seconds or longer while current time is displayed to switch the function On/Off.
01: On
7
0
3
Cool Temp Max
8
8
1
9
30
10
6
1
11
0
3
12
8
1
13
7
2
14
7
1
00: 5 levels (Cool in 5 levels) + Swing + Stop
01: 5 levels (Cool in 3 levels) + Swing + Stop
02: 5 levels (Cool in 3 levels) + Swing
03: /
04: / / /
05: / /
03: Swing
04: No switchable function
00: 5 levels (1 to 5, Auto)
01: 3 levels (Low (1), Medium (3), High (5), Auto)
02: 3 levels (Low (1), Medium (3), High (5))
03: Low (1), Medium (3)
04: No switchable function
00:
/ / / /
00: / / / /
01: / / /
02: / /
03: /
04: / / /
05: / /
00: 24-hour
01: AM/PM
Cool Temp Min
Heat Temp Max
Heat Temp Min
Dry Temp Max
Dry Temp Min
Auto Temp Max
Auto Temp Min
5 – 35°C
5 – 35°C
5 – 35°C
5 – 35°C
5 – 35°C
5 – 35°C
5 – 35°C
5 – 35°C
00: Off
01: On
00: Off
00: Off
01: On
01: On
Item
Number
2
3
1
2
2
1
1
Note
Make sure to
fi
ll the setting status in the check column after making changes to these settings.