Compact Photoelectric Sensor 

CX-400

 

SERIES Ver.2

Introducing the transparent object sensing type sensor

Our unique optical system and transparent object 

sensing circuitry provide stable sensing of even thinner 

transparent objects than the conventional models.

CX-48

CX-482 

Twice the 

sensing range! 

Twice the 

sensing range! 

Sensing object 

Sensing object size (mm 

in

50 × 50 

1.969 × 1.969

ø50 

ø1.969

 ℓ = 50

 1.969

50 × 50 

1.969 × 1.969

50 × 50 

1.969 × 1.969

50 × 50 

1.969 × 1.969

50 × 50 

1.969 × 1.969

50 × 50 

1.969 × 1.969

ø66 

ø2.598

t = 0.7 

0.028 

t = 1.3 

0.051 

t = 1.0 

0.039 

t = 0.9 

0.035 

t = 10 µm

 0.394 mil 

t = 20 µm

 0.787 mil 

t = 30 µm 

1.181 mil 

Transparent objects detectable with 

CX-48□ 

(Typical examples) 

Reflector setting range 

CX-481

: 300 to 500 mm 

11.811 to 19.685 in

,

 

CX-482

: 1 to 2 m 

3.281 to 6.562 ft

[with the 

RF-230

 reflector at the optimum condition (Note)] 

Each object should pass across the beam at the center between 

the sensor and the reflector. 

ℓ: Length of cylindrical glasses

t: Thickness of sensing object

Note: The optimum condition is defined as the condition in which the 

sensitivity level is set such that the stability indicator just lights 

up when the object is absent. 

Glass sheet
Cylindrical glass
Acrylic board
Styrol (Floppy case)
Food wrapping film
Cigarette case film
Vinyl sack
PET bottle (500mℓ)

Strong on dust and dirt

Because the 

light source is an 

infrared light, it is 

strong on dust and 

dirt compared to 

the red beam type.

ENVIRONMENTAL RESISTANCE

Strong even in cold environments

Stable performance can be maintained even in 

environments of –25 °C 

–13 °F

.

CX-412/413

Stronger noise resistance

Inverter motor

Fluorescent

light 

The 

CX-400

 series has

a higher noise resistance 

than its previons model. By 

incorporating an inverter 

countermeasure circuit that 

appropriately shifts with peak 

wavelength, the sensor now 

resists high-frequency noise 

from high-voltage inverter 

motors and 

inverter lights more effectively.

Ultra-long sensing range of 30 m 

98.4 ft

The 

CX-413

 achieves the 

ultra-long sensing range 

of 30 m 

98.4 ft. 

It can be 

used for a stacker crane 

or a multilevel parking 

structure.

Long sensing range of 5 m 

16.4 ft

A long 5 m 

16.4 ft

 

sensing range is 

possible with the red 

LED type that is easy 

to align with the beam 

axis. Can be used for 

wide automatic door 

shutters.

CX-493

CX-413

BASIC PERFORMANCE

Thoroughly eliminating unnecessary waste, Reducing many environmental burdens

The

 CX-400

 series has three different cable length 

types and uses very simple packaging to reduce 

waste. The bag is made of polyethylene and does not 

emit toxic gasses.

ECO

Содержание CX-400 Series

Страница 1: ...2022 6 Amplifier Built in Compact Photoelectric Sensor CX 400SERIES Ver 2 The contents of this catalog are as of October 2017 For the latest information please visit our company website...

Страница 2: ...ant polycarbonate was used for the front and display covers Safe even for installing near food processing machinery that disperses ethanol based detergents The protection mechanism also conforms to IP...

Страница 3: ...tected at a setting distance of 20 mm 0 787 in 30 higher sensing capability Retroreflective type with polarizing filters Built in polarizing filters ensure stable sensing even on a specular object CX...

Страница 4: ...s Acrylic board Styrol Floppy case Food wrapping film Cigarette case film Vinyl sack PET bottle 500m Strong on dust and dirt Because the light source is an infrared light it is strong on dust and dirt...

Страница 5: ...he sensing range enables you to make optimal volume adjustment easily OPERABILITY Can be used for sensing minute differences Equipped with a 5 turn adjuster so that even challenging range settings can...

Страница 6: ...round suppression function The sensor judges that an object is present when light is received at position A of the light receiving element 2 segment element This is useful if the object and background...

Страница 7: ...able either Detection ON or Detection OFF Red LED CX 443 CX 443 P 15 to 100 mm 0 591 to 3 937 in CX 444 CX 444 P 20 to 300 mm 0 787 to 11 811 in CX 442 CX 442 P NOTE Mounting bracket is not supplied w...

Страница 8: ...ing bracket is not supplied with the sensor Please select from the range of optional sensor mounting brackets Notes 1 The model No with E shown on the label affixed to the thru beam type sensor is the...

Страница 9: ...iled type is not available for CX 44 Excluding basic type e g M8 connector type of CX 411 P is CX 411 P Z M12 pigtailed type of CX 411 P is CX 411 P J Mating cable 2 cables are required for the thru b...

Страница 10: ...91 1 m 3 281 ft Note 2 30 mm 1 181 in CX 493 1 5 m 4 921 ft Note 2 CX 481 CX 483 0 1 to 0 3 m 0 328 to 0 984 ft Note 2 CX 482 0 1 to 0 6 m 0 328 to 1 969 ft Note 2 RF 220 CX 491 1 5 m 4 921 ft Note 2...

Страница 11: ...to 0 1 m 0 328 ft CX 482 0 4 m 1 312 ft or more 3 Set the distance between the sensor and the reflective tape to 0 2 m 0 656 ft or more Reflector mounting bracket MS RF23 Reflective tape Sensor mount...

Страница 12: ...unction Twounitsofsensors canbemounted closetogetherwith interferenceprevention filters Sensingrange 5m16 404ft Incorporated Two units of sensors can be mounted close together Environmental resistance...

Страница 13: ...Storage 30 to 70 C 22 to 158 F Ambient humidity 35 to 85 RH Storage 35 to 85 RH Ambient illuminance Incandescent light 3 000 x or less at the light receiving face Voltage withstandability 1 000 V AC...

Страница 14: ...nits of sensors can be mounted close together Environmental resistance Protection IP67 IEC Ambient temperature 25 to 55 C 13 to 131 F No dew condensation or icing allowed Storage 30 to 70 C 22 to 158...

Страница 15: ...table range reflective type When using the CX 44 be sure to wire the sensing mode selection input pink 2 Unstable operation may occur PNP output type I O circuit diagram Tr ZD ZD 100 mA max User s cir...

Страница 16: ...des Vertical direction 2 6 562 4 13 123 Emitter L Horizontal direction Slitonbothsides Horizontal direction Receiver 0 0 CX 412 Thru beam type Parallel deviation Parallel deviation with round slit mas...

Страница 17: ...8 26 247 0 Left Center Operating point mm in Setting distance L m ft Right Sensor L 2 6 562 4 13 123 6 19 685 8 26 247 0 Sensor angular deviation L Sensor Reflector RF 230 Sensor angular deviation 40...

Страница 18: ...range shortens as shown in the left graph 0 079 0 039 0 039 0 079 2 1 0 1 2 0 100 3 937 200 7 874 N6 White Setting distance L mm in Left Right Center Operating point mm in 200 200 mm 7 874 7 874 in N...

Страница 19: ...k Red Blue Gray Sensing range L mm in 50 mm 1 969 in 25 mm 0 984 in 20 0 787 40 1 575 60 2 362 30 1 181 50 1 969 80 3 150 0 6 2 mm 0 244 in 5 9 mm 0 232 in 5 3 mm 0 209 in 6 5 mm 0 256 in Distance L m...

Страница 20: ...ard Plywood Black rubber Gray non glossy paper Lightness 5 Sensing range L mm in Sensing fields CX 442 Adjustable range reflective type Setting distance 300 mm 11 811 in Setting distance 100 mm 3 937...

Страница 21: ...rk ON as per your requirement with the operation mode switch PRECAUTIONS FOR PROPER USE All models Mounting The tightening torque should be 0 5 N m or less Others Do not use during the initial transie...

Страница 22: ...ng the stable sensing condition by turning the sensing object etc When sensing pipe shaped transparent sensing object set it in a standing not lying position as shown in Figure A The sensor may fail t...

Страница 23: ...the object may not be detected due to a change in angle wrinkles on the object surface etc When a specular body is present below the sensor use the sensor by tilting it slightly upwards to avoid wrong...

Страница 24: ...adjuster clockwise further until the sensor goes into the detecting state again Once it has entered turn the distance adjuster backward until the sensor returns to the non detecting condition This pos...

Страница 25: ...0 610 3 7 0 146 cable Beam axis 11 2 0 441 2 M3 0 5 0 020 thru hole threads 300 11 811 44 1 732 3 95 0 156 7 85 0 309 11 8 0 465 Operation indicator Orange Stability indicator Green Sensitivity adjus...

Страница 26: ...6 0 181 mounting holes 50 3 1 980 40 1 575 5 0 197 8 3 0 327 3 3 0 130 10 0 394 59 3 2 335 49 3 1 941 30 1 181 35 3 1 390 42 3 1 665 34 3 1 350 25 0 984 2 3 6 0 142 mounting holes 4 0 157 8 0 315 8 3...

Страница 27: ...76 23 0 906 10 0 394 8 3 4 0 134 holes R12R0 472 14 0 551 7 0 276 14 0 551 36 1 417 55 2 165 22 0 866 25 0 984 15 5 0 610 R0 472 Beam axis 15 8 0 622 8 2 0 323 t 2 t 0 079 3 6 0 142 4 0 157 14 0 551 4...

Страница 28: ...or mounting bracket Optional t 1 2 t 0 047 20 5 0 807 3 5 0 138 3 4 0 134 3 4 0 134 10 R25 R0 984 5 0 197 3 4 0 134 10 5 0 197 15 0 591 14 0 551 8 0 315 3 4 0 134 6 0 236 8 5 0 335 6 0 236 30 1 181 35...

Страница 29: ...le threads 25 0 984 4 5 0 177 25 0 984 10 0 394 28 3 1 114 8 3 0 327 34 3 1 350 8 0 315 4 0 157 21 0 827 35 3 1 390 44 3 1 744 6 0 236 27 1 063 t 1 6 t 0 063 19 3 0 760 DIMENSIONS Unit mm in Material...

Страница 30: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent...

Отзывы: