53
7 Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor
unit according to the diagram below.
Terminals on the outdoor unit
S1
2
3
1
2
3
Colour of wires (connection cable)
Terminals on the indoor unit
L
1
N
S1
2
3
OR
L
1
N
S1
2
3
(Power supply cord)
*
Connection for multi inverter
model (Outdoor power
supply)
Terminals on the isolating devices
(Disconnecting means)
(L) (N)
8 Secure the power supply cord and connection cable onto the control board with the holder.
9 Close grille door by tighten with screw and close the front panel.
Connection cable
Power supply cord
Terminal Board
Control Board
Recommended
length (mm)
Earth Wire
longer than
others AC
wires for safety
reason
Holder
Holder
Indoor & outdoor
connection cable
Power supply
cord
Outdoor unit
Isolating Devices
Tape
Tape
Recommended
length (mm)
a
b
c
d
e
f
g
55 35 35 50 40 35 60
WARNING
This equipment must be properly earthed.
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the
electrical safety in case of the slipping out of the cord from the anchorage.