175
21. Service
Data
Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced
heating mode.
21.1 Cool Mode Outdoor Air Temperature Characteristic
Condition
-
Indoor room temperature: 27°C Dry Bulb/19°C Wet Bulb
-
Unit setting: Standard piping length, forced cooling at 16°C, Hi fan
-
Compressor frequency: Rated for cooling operation
-
Piping length: 5m
-
Voltage:
230V
21.1.1 CS-Z20VKEW
CU-Z20VKE
CS-XZ20VKEW CU-Z20VKE
Indoor Discharge
Air Temperature (°C)
Outdoor Air Temperature (°C)
Low Pressure (MPa)
Outdoor Air Temperature (°C)
Current (A)
Outdoor Air Temperature (°C)
1.00
1.50
2.00
2.50
3.00
12
16
20
24
28
32
36
40
44
48
0.80
0.90
1.00
1.10
1.20
1.30
1.40
12
16
20
24
28
32
36
40
44
48
12.00
13.00
14.00
15.00
16.00
17.00
18.00
19.00
20.00
21.00
22.00
12
16
20
24
28
32
36
40
44
48