Indoor Unit
Demonstration Mode
When the remote control cannot be used or
for repairing and testing ,please use this
button.
Power Switch ON/OFF
Signal Receiving Sound Control
Keep pressing this button for 10seconds to turn
on or turn off the signal receiving sound.
Operation Indication Lamps
Power (green)
Timer(orange)
Lights up in operation;
Blinks during Test
Run operation and
determining Auto
Operation mode
Timer in operation
Operation Mode
Cooling/Heating/Soft Dry /Auto Operation
/ Air circulation
Time Delay Safety Control
The unit will restart operation in 3-4
minutes after each pause.
7-Minutes Time Save Control
7-minutes automatic restarting at Cooling
Operation
National
4
Keep pressing this button for 15seconds to start
or end the Demonstration Mode.
Auto Switch
Button
Air quality
Green
Orange
Red
Anti-freezing Control for the Evaporator
Cooling or Soft Dry Operation
Warm Booting Control
Indoor fan starts running when temperature
of evaporator reaches 30
or above.
When temperature of evaporator is between
30
and 34
,indoor fan will run at Super Low
or Low speed.
When temperature of evaporator reaches 34
,
Warm Booting Operation ends.
High,Med,Low
Auto Fan Speed
Indoor Fan Speed Control
Automatic Airflow Direction Control
The louver automatically swings up and down
Airflow Direction Manual Control
Airflow Direction Control
Delayed On-timer Control
For cooling or soft dry mode, the unit
starts 15 minutes before the set time with
the remote control, but for heating mode
30 minutes before the set time.
CS-PC12DKD / CU-PC12DKD / CS-PA12DKD / CU-PA12DKD
(For PA12DKD only)