Multi air conditioner system
Multi air conditioner systems save space by letting you connect
multiple indoor units to a single outdoor unit.
• For complete product features, please refer catalogue.
Indoor units
• It is possible to operate the indoor units individually or
simultaneously. The priority of operation is placed on the
fi
rst
unit that turned on.
• During operation, HEAT and COOL modes cannot activate at
the same time for different indoor units.
• The power indicator blinks to indicate the indoor unit is
standing by for a different operation mode.
• For system which HEAT mode has been locked, if operation
mode other than HEAT is selected, the indoor unit stops and
the POWER indicator blinks.
Indoor units
Multi split outdoor unit
Accessories
• Remote control
• AAA or R03 batteries × 2
• Remote control holder
• Screws for remote control
holder × 2
3
English
Operation conditions
Use this air conditioner under the following temperature range.
DBT: Dry bulb temperature / WBT: Wet bulb temperature
Multi split outdoor unit
Temperature (°C)
Indoor
CU-3E18PBE, CU-4E23PBE,
CU-4E27PBE, CU-5E34PBE,
CU-2E12SBE, CU-2E15SBE,
CU-2E18SBE, CU-3E23SBE
CU-2RE15SBE
CU-2RE18SBE
CU-3RE18SBE
DBT
WBT
DBT
WBT
DBT
WBT
COOL
Max. 32
23
46
26
43
26
Min. 16
11
-10
-
16
11
HEAT
Max. 30
-
24
18
24
18
Min. 16
-
-15
-16
-10
-11