Press the Power Button on the Remote Control to select the Serviceman Adjustment
For Adjustments:
Geometry Adjustments
Default
Level
D00
H POSITION
13
D01
V SIZE
37
D02
V S CORRECTION
5
D03
V LIN CORRECTION
8
D04
E/W TRAPEZIUM
9
D05
V AGC
1
D06
V POSITION
1
D07
V CENTERING
65
D08
V CENTERING DAC SW
0
D09
V-BLK START
12
D0A
V-BLK STOP
14
D0B
EW CORNER
6
D0C
EW PARABOLA
11
D0D
H WIDTH
20
D0E
OSD POSITION
90
MTS Adjustment
Default
Level
M00
INPUT LEVEL
33
M01
LOW-LEVEL SEPARATION
6
M02 HIGH-LEVEL
SEPARATION
25
1.Press Channel Up/Down on the
Remote Control to select one of
the available Service Adjustments
(a in Fig. 20).
Note: Write Down the original
value set (b in
Fig. 20
) for
each address before
modifying anything. It is
easy to erroneously adjust
the wrong item.
2.Press Volume Up/Down on the
Remote Control to adjust the
level of the selected Service
Adjustment (b in Fig. 20).
IMPORTANT NOTE:
Always Exit the Serviceman
Mode Following Adjustments.
Note: Some adjustment modes may not be
available in some formats.
CH
CH
CH
PW
To P Items.
PW
CH
Содержание CT-32SX31E
Страница 19: ... 54 ALL MODELS A Board Schematic Left Portion Diagrama Eléctrico de la Tarjeta A Sección Izquierda ...
Страница 22: ... 58 ALL MODELS D Board Schematic Diagrama Eléctrico Tarjeta D ...
Страница 23: ... 60 ALL MODELS G Board Schematic Diagrama Eléctrico Tarjeta G ...
Страница 39: ... 64 Printed in USA K01052223PL0531 ...