Instructional Flow Chart for Serviceman Mode
Adj.
needed?
NORMAL MODE
Momentarily short FA1 to FA2
.
Press Volume Up Simultaneously (ON Receiver)
Adj.
needed?
WHITE
SCREEN
(ON REMOTE)
RECALL
WHITE
SCREEN
RED
SCREEN
GREEN
SCREEN
BLUE
SCREEN
POWER
(ON REMOTE)
AGING MODE
•
Yellow “CHK” appears in upper left corner of screen.
•
Volume Up/Down operate rapidly.
•
Customer Controls are set to nominal level.
SERVICEMAN MODE
•
“CHK” turns red.
•
Volume Up/Down operate normally.
•
Customer Controls are set to nominal level.
SUB-DATA ADJUSTMENTS.
B ITEMS.
QUICK ENTRY TO SERVICEMAN MODE
•
Select CABLE Mode.
•
Set SLEEP time for 30 Min.
•
Tune to Channel 124.
•
Adjust Volume to minimum.
•
Press VOL DOWN On Receiver.
EXIT
EXIT
Figure 22. Flow Chart for Serviceman Mode.
N
Y
N
Y
C
(ON REMOTE)
RECALL
Press Action and Power on the Receiver
simultaneously for at least 2 seconds.
ON REMOTE CONTROL TO
SELECT ADJUSTMENT
ON REMOTE TO ADJUST
THE LEVEL
CH
VOL VOL
POWER
(ON REMOTE)
A
IMPORTANT NOTE:
Always Exit the Serviceman
Mode Following Adjustments.