 Safety Precautions

2-3. Checking for presence of refrigerant

• The area shall be checked with an 

appropriate refrigerant detector prior to and 
during work, to ensure the technician is aware 
of potentially 

fl

 ammable atmospheres.

• Ensure that the leak detection equipment 

being used is suitable for use with 

fl

 ammable 

refrigerants, i.e. non sparking, adequately 
sealed or intrinsically safe.

• In case of leakage/spillage happened, 

immediately ventilate area and stay upwind 
and away from spill/release.

• In case of leakage/spillage happened, do 

notify persons down wind of the leaking/
spill, isolate immediate hazard area and keep 
unauthorised personnel out.

2-4. Presence of 

fi

 re extinguisher

• If any hot work is to be conducted on the 

refrigerating equipment or any associated 
parts, appropriate 

fi

re extinguishing 

equipment shall be available at hand.

• Have a dry powder or CO

2

 

fi

 re extinguisher 

adjacent to the charging area.

2-5. No ignition sources

• No person carrying out work in relation to a 

refrigerating system which involves exposing 
any pipe work that contains or has contained 

fl

ammable refrigerant shall use any sources 

of ignition in such a manner that it may lead to 
the risk of 

fi

re or explosion. He/She must not 

be smoking when carrying out such work.

• All possible ignition sources, including 

cigarette smoking, should be kept suf

fi

 ciently 

far away from the site of installation, 
repairing, removing and disposal, during 
which 

fl

 ammable refrigerant can possibly be 

released to the surrounding space.

• Prior to work taking place, the area around 

the equipment is to be surveyed to make 
sure that there are no 

fl

 ammable hazards or 

ignition risks.

• “No Smoking” signs shall be displayed.

2-6. Ventilated area

• Ensure that the area is in the open or that it is 

adequately ventilated before breaking into the 
system or conducting any hot work.

• A degree of ventilation shall continue during 

the period that the work is carried out.

• The ventilation should safely disperse any 

released refrigerant and preferably expel it 
externally into the atmosphere.

2-7. Checks to the refrigerating equipment

• Where electrical components are being 

changed, they shall be 

fi

 t for the purpose and 

to the correct speci

fi

 cation.

• At all times the manufacturer’s maintenance 

and service guidelines shall be followed.

• If in doubt consult the manufacturer’s 

technical department for assistance.

• The following checks shall be applied to 

installations using 

fl

 ammable refrigerants.

 

- The actual refrigerant charge is in 

accordance with the room size within 
which the refrigerant containing parts are 
installed.

 

- The ventilation machinery and outlets 

are operating adequately and are not 
obstructed. 

 

- If an indirect refrigerating circuit is being 

used, the secondary circuit shall be 
checked for the presence of refrigerant.

 

- Marking to the equipment continues to be 

visible and legible. Markings and signs that 
are illegible shall be corrected.

 

- Refrigerating pipe or components are 

installed in a position where they are 
unlikely to be exposed to any substance 
which may corrode refrigerant containing 
components, unless the components 
are constructed of materials which are 
inherently resistant to being corroded or 
are properly protected against being so 
corroded.

2-8. Checks to electrical devices

• Repair and maintenance to electrical 

components shall include initial safety checks 
and component inspection procedures.

• Initial safety checks shall include but not limit 

to:-

 

- That capacitors are discharged: this 

shall be done in a safe manner to avoid 
possibility of sparking. 

 

- That there no live electrical components 

and wiring are exposed while charging, 
recovering or purging the system. 

 

- That there is continuity of earth bonding.

• At all times the manufacturer’s maintenance 

and service guidelines shall be followed.

• If in doubt consult the manufacturer’s 

technical department for assistance.

• If a fault exists that could compromise safety, 

then no electrical supply shall be connected to 
the circuit until it is satisfactorily dealt with.

• If the fault cannot be corrected immediately 

but it is necessary to continue operation, an 
adequate temporary solution shall be used.

• The owner of the equipment must be 

informed or reported so all parties are advised 
thereinafter.

ACXF55-31442_SS1221-2_EN.indd   8

ACXF55-31442_SS1221-2_EN.indd   8

29/11/2021   5:01:32 PM

29/11/2021   5:01:32 PM

Содержание CS-Z50XKRW-1

Страница 1: ...tomer keep them for future reference Remove the remote control packed with the indoor unit Kindly consult authorised dealer for connectivity validity Model No Indoor Unit Outdoor Unit Single Split CS Z50XKRW 1 CS Z60XKRW CS Z60XKRW 1 CS Z71XKRW CS Z80XKR CU Z50XKR 1 CU Z60XKR CU Z60XKR 1 CU Z71XKR CU Z80XKR Outdoor Unit Multi Split CU 4Z71VBR CU 4Z80VBR CU 5Z100VBR ACXF55 31442 English ACXF55 3144...

Страница 2: ...ner to suit your needs For complete product features please refer to catalogue Inserting the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press CLOCK then press to set the time Press CLOCK for approximately 5 seconds to show the time as 12 hour am pm or 24 hour 2 Press to confirm B A POWERFUL ECO ACXF55 31442_SS1221 2...

Страница 3: ...re subject to change without notice B Basic operation Thank you for purchasing Panasonic Air Conditioner 1 Press to start stop the operation POWER When the unit is ON disappears from the remote control display 3 Press TEMP UP TEMP DOWN to select the desired temperature Up Down Selection range 16 0 C 30 0 C 60 F 86 F Press for approximately 10 seconds to show the temperature as C or F 2 Press to se...

Страница 4: ...appliance Please consult an authorised dealer or specialist to clean the internal parts repair install remove disassemble and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury ...

Страница 5: ...r unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or pet directly to airflow to avoid injury etc Do not to...

Страница 6: ...is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants and as recommended by the manufacturer Any personnel conducting an operation servicing or maintenance on a system or associated parts of the equipment should be trained and certified Any part of refrigerating circuit evaporators ...

Страница 7: ... to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised and maintained by a trained and certified service personnel who is employed by the person user or party responsible Ensure the actual refrigerant charge is in accordance with the room size within which the refrigerant containing parts are installed Ensure refrigerant charg...

Страница 8: ...rating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to installations using flammable refrigerants The actual refrigerant cha...

Страница 9: ...ect to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans 6 Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching or detection of refrigerant leaks A halide torch...

Страница 10: ...ylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging the system with refrigerant Label the system when charging is complete if not already Extreme care shall be taken not to over fill the refrigerating system Prior to recharging the system it shall be pressure tested with OFN refer to 7 The system shall be...

Страница 11: ...l system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment sh...

Страница 12: ...er To Learn More This operation provides cleaner air moisturises your skin and hair and deodorises odours in the room Press nanoe X to activate this operation either when the unit is ON or OFF During nanoe X individual operation the fan speed will follow the remote control setting If nanoe X is activated before the unit is turned off the nanoe X operation will resume when the unit is turned on Thi...

Страница 13: ... in iAUTO X mode To reach the desired temperature quickly For Wireless LAN Module operation setup please refer to additional Setup Instructions Manual To connect to a network This operation provides you with a comfortable environment while sleeping It will automatically adjust the sleep pattern temperature during the activation period The indoor unit indicator will dim when this operation is activ...

Страница 14: ... timer setting is displayed and will activate in sequence The timer operation follows the clock setting on the remote control and will repeat daily when timer has been set For clock setting refer to Quick Guide Note Can be selected at the same time POWERFUL QUIET and FAN SPEED cannot be selected at the same time 3 1 2 1 Select TIMER ON or TIMER OFF Example OFF at 22 00 Each time pressed exit setti...

Страница 15: ...atically with the last operation mode and airflow direction This control is not applicable when TIMER is set To Learn More Single Single split system Multi Multi split system Operation mode It is possible to operate the indoor units individually or simultaneously The priority of operation is placed on the first unit that turned on During operation HEAT and COOL modes cannot activate at the same ti...

Страница 16: ...x 32 89 6 23 73 4 46 114 8 26 78 8 46 114 8 26 78 8 Min 16 60 8 11 51 8 10 14 0 10 14 0 HEAT Max 30 86 0 24 75 2 18 64 4 24 75 2 18 64 4 Min 16 60 8 15 5 0 15 5 0 16 3 2 DBT Dry bulb temperature WBT Wet bulb temperature 1 CU Z50XKR 1 CU Z60XKR CU Z60XKR 1 CU Z71XKR CU Z80XKR 2 CU 4Z71VBR CU 4Z80VBR CU 5Z100VBR ACXF55 31442_SS1221 2_EN indd 16 ACXF55 31442_SS1221 2_EN indd 16 29 11 2021 5 01 33 PM ...

Страница 17: ...rface Dry the filters thoroughly under a shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach air filter Remove from the unit Insert into the unit Indoor unit Wipe the unit gently with a soft and dry cloth The coils and fans should be cleaned periodically by an authorised dealer Outdoor unit Clean the debris that surround the unit Clear any blockage from the...

Страница 18: ...s is to help remove the surrounding odour Airflow continues even after operation has stopped To extract the remaining heat from the indoor unit maximum 30 seconds The room has a peculiar odour This may be due to damp smell emitted by the wall carpet furniture or clothing Cracking sound during operation Changes in temperature caused the unit to expand and contract Water flowing sound during operati...

Страница 19: ...weak Insert the batteries correctly Replace weak batteries The unit does not work Check if the circuit breaker is tripped Check if timers have been set The unit does not receive the signal from the remote control Make sure the receiver is not obstructed Certain fluorescent lights may interfere with the signal transmitter Consult an authorised dealer The nanoe X indicator at the indoor unit is not ...

Страница 20: ... a malfunction has occurred above After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units will not be used for an extended period Activate HEAT mode for 2 3 hours to remove any moisture left in the internal parts thoroughly This is to prevent mould growth Turn off the power supply and ...

Страница 21: ...36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand code H 39 Abnormal indoor operating unit or standby units Diagnostic display Abnormality Protection control H 41 Abnormal wiring or piping connection H 50 Ventilation fan motor locked H 51 Ventilation fan motor locked H 52 Left right limit switch fixing abno...

Страница 22: ...by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows type of flammable refrigerant contained in the system This symbol shows that a serv...

Страница 23: ...23 Memo Information English ACXF55 31442_SS1221 2_EN indd 23 ACXF55 31442_SS1221 2_EN indd 23 29 11 2021 5 01 37 PM 29 11 2021 5 01 37 PM ...

Страница 24: ...poration 1006 Kadoma Kadoma City Osaka Japan Website http www panasonic com Panasonic Corporation 2021 ACXF55 31442 SS1221 2 ACXF55 31442_SS1221 2_EN indd 24 ACXF55 31442_SS1221 2_EN indd 24 29 11 2021 5 01 37 PM 29 11 2021 5 01 37 PM ...

Отзывы: