![Panasonic CS-YE9WKU1 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/panasonic/cs-ye9wku1/cs-ye9wku1_operating-instructions-manual_4709567029.webp)
INSTALLATION MANUAL---Information for the installer
(1) Refer to the data rating label sticked on the outdoor unit.
TIGHTENING TORQUE FOR PROTECTION CAPS AND FLANGE CONNECTION
PIPE
1/4
( 6)
3/8
(
9.52)
1/2
(
12)
5/8
(
15.88)
TIGHTENING TORQUE
[lbf x ft]
TIGHTENING TORQUE
CORRESPONDING STRESS
(using a 20 cm wrench)
11.07-14.76
22.88-25.83
25.83-33.21
55.35-59.04
Service port nut
Protection caps
5.17-6.64
18.45-22.14
wrist strength
arm strength
arm strength
arm strength
MODEL capacity (Btu/h)
9K
12K
Liquid pipe diameter
Gas pipe diameter
Length of pipe with standard charge
Maximum distance between indoor and outdoor unit
Max. diff. in level between indoor and outdoor unit
Type of refrigerant(1)
1/4
( 6)
1/4
( 6)
3/8
(
9.52)
3/8
(
9.52)
24.61 ft
24.61 ft
49.21 ft
49.21 ft
6.17g/ft
6.17g/ft
16.40 ft
INVERTER TYPE
Additional refrigerant charge
R410A
R410A
26
16.40 ft