INSTALLATION---Selecting the Installation Place
Install the indoor unit level on a strong wall that is not
subject to vibrations.
The inlet and outlet ports should not be obstructed: the
air should be able to blow all over the room.
Do not install the unit near a source of heat, steam, or
flammable gas.
Install the unit near an electric socket or private circuit.
Do not install the unit where it will be exposed to
direct sunlight.
Install the unit where connection between indoor and
outdoor unit is as easy as possible.
Install the unit where it is easy to drain the condensed
water.
Check the machine operation regularly and leave the
necessary space (as shown in the picture).
Install the indoor unit where the filter can be easily
accessible.
condensed water drain pipe
6
Sleeve
insulating covering
electrical cable
Mounting plate
Do not install the outdoor unit near sources of heat,
steam or flammable gas.
Do not install the unit in too windy or dusty places.
Do not install the unit where people often pass.Select
a place where the air discharge and operating sound
level will not disturb neighbours.
Avoid installing the unit where it will be exposed
to direct sunlight (other wise use a protection, if
necessary, that should not interfere with the air flow).
Leave space as shown in the picture for the air to
circulate freely.
Install the outdoor unit in a safe and solid place.
If the outdoor unit is subject to vibration, place rubber
gaskets onto the feet of the unit.
water drain pipe
Minimum space to be left showing in the
picture
Outdoor unit
Indoor unit
Pipe length is
50' Max
b
e
le
ss
t
h
an
1
6
.4
0
f
t
H
ei
g
h
t
s
h
o
u
ld
Outdoor unit
Indoor unit
Pipe length is
50' Max
b
e
le
ss
t
h
an
1
6
.4
0
f
t
H
ei
g
h
t
s
h
o
u
ld
Installation Diagram
INDOOR UNIT
OUTDOOR UNIT
Only persons and/or companies qualified and experienced in the installation, service and repair of refrigerant
products should be permitted to do so. The purchaser must ensure that the person and/or company who is to
install, service or repair this air conditioner has qualifications and experience in refrigerant products.
6
6
20
20
12
12
79
This service information is designed for experienced repair technicians only and is not designed for use by the
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any
attempt to service or repair the products dealt with in this service information by anyone else could result in
serious injury or death.
WARNING