![Panasonic CS-YE12MKE Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/panasonic/cs-ye12mke/cs-ye12mke_service-manual_1508259031.webp)
31
30 s
Compressor
Outdoor Fan
ON
ON
OFF
OFF
ON
Airflow Direction
12.3.1 Vertical
Airflow
Cooling
Operating Mode
1 2 3 4 5
10 ~50
o
o
Soft dry
Auto
Normal
Powerful
35
, 6
o
o
(Begining of POWERFUL mode)
Heating
12
o
Auto
Normal
Powerful
12
o
10 22 31 40 50
o
o
o
o
o
8
o
o
o
o
, 9 , 39 , 41 ,
Auto
Normal
Powerful
10 22 31 40 50
o
o
o
o
o
8 24 37 51 63
o
o
o
o
o
8
o
o
o
o
, 9 , 35 , 39 ,
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated
above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature. When the air
conditioner is stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control. The angels of the vane are as stated above. When the air
conditioner is stopped using remote control, the vane will shift to close position.
* Above angle data is for reference only.
12.3.2 Horizontal
Airflow
The horizontal airflow direction louvers can be adjusted manually by hand.
12.3.3 Quiet operation
●
To provide quiet operation comparing to normal operation. The Quiet operation can be active or stop by pressing
QUIET/POWERFUL button on remote control.
●
Once Quiet mode is active ,the unit will continuously operate in QUIET Mode until cancel the mode by pressing
QUIET/POWERFUL button on remote control.
12.3.4 Powerful
operation
●
To cooling or heating the room faster comparing to normal operation. The POWERFUL operation can be active or
stop by pressing QUIET/POWERFUL button
on
remote control.
●
When powerful operation is active, the unit will continuously operate in POWERFUL mode until cancel the mode by
pressing QUIET/POWERFUL button on remote control. Operation details are as the fig. below.
1. For cooling, soft Dry mode
18
o
28
o
37
o
46
o
55
o
18
o
~
55
o
30
o
13
o
18
o
28
o
37
o
46
o
55
o
20
o
20
o
18
o
(POWERFUL)
18
o
34
o
50
o
64
o
79
o
Содержание CS-YE12MKE
Страница 11: ...11 5 Dimensions 5 1 Indoor Unit 121 49 Unit mm ...
Страница 12: ...12 5 2 Outdoor Unit Unit mm ...
Страница 13: ...13 6 Refrigeration Cycle Diagram CS CU YE9MKE CS CU YE12MKE CS CU YE18MKE COOLING HEATING ...
Страница 14: ...14 7 Block Diagram CS CU YE18MKE CS CU YE9 12MKE ...
Страница 15: ...15 8 Wiring Diagram CS YE9MKE CS YE12MKE ...
Страница 16: ...16 CU YE9MKE CU YE12MKE ...
Страница 17: ...17 CS YE18MKE ...
Страница 18: ...18 CU YE18MKE ...
Страница 22: ...22 10 2 3 Indoor Unit Installation ...
Страница 40: ...40 14 2 3 Error Codes Table ...
Страница 44: ...44 16 Exploded View and Replacement Pars List 16 1 Indoor Unit CS YE9MKE CS YE12MKE CS YE18MKE ...
Страница 46: ...46 16 2 Outdoor Unit CU YE9MKE CU YE12MKE CU YE18MKE ...