10
BEE Regulation
Step a): Press and Hold the button on indoor unit.
Control button when display is showing
OFF, while holding the indoor unit button.
Step b): Within 5 second, press once the Remote
Turn on the main power supply to unit.
•
•
•
Testing Guidelines
Cooling Test Mode for Full Load (100%) and
Half Load (50%)
1) Mode
: Select ‘COOL’
2) Temperature
: a) 16 ºC for Full Load (100%)
3) Air Swing
Vertical Airflow
: Set vane position to 3rd step
from top
: b) 17 ºC for Half Load (50%)
(For Full Load)
QUIET
CLEAN
Note: Unit is charged with extra 60g refrigerant for installation purging purpose.
For all laboratory tests, 60g shall be released to follow the rated refrigerant amount mentioned in nameplate.
Open the Front Panel by lifting Intake Grille.
Follow the below Instructions.
4) Air Swing
Horizontal Airflow
: Set vane position to be
straight
(For applicable Model)
5) Fan speed
: Maximum
1
2
1
2
(For Half Load)
QUIET
CLEAN
1
2
1
2
(Indication for Half load)
(Indication for Full load)
POWER
TIMER
nanoe-G
PURIFIER
SLEEP /
POWERFUL
POWER
TIMER
nanoe-G
PURIFIER
SLEEP /
POWERFUL
THREE LEDs FROM BOTTOM
STARTS BLINKING
TWO LEDs FROM BOTTOM
STARTS BLINKING
Step c): After hearing a beep sound from the Indoor
Unit, immediately release the (Auto OFF/ON)
button on Indoor Unit.
All this should be done within 5 seconds.
(Auto OFF/ON Button)