background image

ENGLISH

5

 Operations Details

•  To provide fresh air effect by 

producing negative ions.

•  To achieve setting temperature 

quickly. It will operate for 15 minutes 
and return to the previous setting.

ION

POWERFUL

Enables 
powerful 
operation.

Enables ion 
operation.

ION

ION

Powerful, Quiet, Ion, Fan Speed, 

Powerful, Quiet, Ion, Fan Speed, 

Air Swing

Air Swing

POWERFUL

POWERFUL

Select fan speed.

FAN SPEED

FAN SPEED

Adjust the 
vertical airfl ow 
direction louver.

AIR SWING

AIR SWING

Enables quiet 
operation.

QUIET

QUIET

•  To provide you with the various fan 

speed selections.

•  There are 3 levels of fan speed in 

addition to automatic fan speed.

•  Automatic fan speed:
  The speed of the indoor fan is 

automatically adjusted according to 
the operation.

FAN SPEED

•  To provide a quiet environment.

QUIET

•  To ventilate air in the room.
•  There are 5 selections in addition to 

automatic vertical air 

fl

 ow direction.

•  If automatic vertical air

fl

 ow direction 

has been set, the louver swings up 
and down automatically.

•  Please do not adjust the vertical 

air

fl

 ow direction louver manually.

• Horizontal air

fl

 ow direction louver 

could be adjusted manually.

AIR SWING

 Ion operation could be activated independently.

 Powerful and Quiet operations could not be activated at the 

same time.

 Powerful, Quiet and Ion operations could be cancelled by 

pressing the respective button again.

HOW TO OPERATE

  ION indicator on the indoor unit is blinking.

  Press ION button twice. If the indicator is still blinking, please consult the 

dealer.

  Indoor fan stops occasionally during Automatic Fan 

Speed setting.

  This is an advanced feature that helps to remove smell from the 

surrounding area during operation.

  Indoor fan stops occasionally during heating operation.

  To avoids unintended cooling effect.

Hints

  If you wish to have the cool air blowing directly on you, set the air

fl

 ow direction downward but not for an excessive length of time, 

as it may harm your health.

  Approximately 10% of electricity can be saved if you set the temperature 1°C higher in cooling operation or 2°C lower in heating 

operation than the desired temperature.

Troubleshooting

Содержание CS-W7DKR

Страница 1: ...R CU W9DKR CS W12DKR CU W12DKR Manufactured by Panasonic HA Air Conditioning M Sdn Bhd Lot 2 Persiaran Tengku Ampuan Section 21 Shah Alam Industrial Site 40300 Shah Alam Selangor Malaysia ENGLISH Before operating the unit read these operating instructions thoroughly and keep them for future reference 2 7 ...

Страница 2: ...n of the remote control In case of emergency or abnormal condition burnt smell etc occurs turn off the power supply and unplug Do not share power outlet Do not modify power cord Do not use an extension cord Do not operate with wet hands Do not operate or stop the unit by inserting or pulling out the power plug Do not insert finger or other objects into the indoor or outdoor unit Do not attempt to ...

Страница 3: ...beep OFF short beep ON Auto OFF ON Button 1 Pull out 2 Insert batteries AAA or R03 3 Press CLOCK button 4 Set current time 5 Press again to confirm Troubleshooting Operation delayed for few minutes after restart This is a normal self protection control Sound like water flowing during operation Caused by refrigerant flow inside Mist emerges from indoor unit Condensation effect due to cooling proces...

Страница 4: ... and Ion operations could be activated in all operation modes Press OFF ON button again to stop the operation Operation Details The unit will automatically select the operation mode according to the room temperature Once the operation mode is selected the unit will operate at the standard setting temperature as shown Room temperature Operation mode Standard setting temperature 23 C above Cool 25 C...

Страница 5: ... swings up and down automatically Please do not adjust the vertical airflow direction louver manually Horizontal airflow direction louver could be adjusted manually AIR SWING Ion operation could be activated independently Powerful and Quiet operations could not be activated at the same time Powerful Quiet and Ion operations could be cancelled by pressing the respective button again HOW TO OPERATE ...

Страница 6: ...nditioner operation at the desired time This can save electricity while you are going out or sleeping The set timer will repeat daily once it is set If there is a power failure you can press SET button to restore the previous setting once the power is resumed If the timer is cancelled you can restore the previous setting by pressing SET button TIMER Press CLOCK more than 10 seconds to change the t...

Страница 7: ...hinner or scouring powder Use soaps or neutral household detergent pH7 only Do not use water with temperature higher than 40 C Preparation for extended Non operation It is recommended to clean the ionizer every 6 months IONIZER This inspection is recommended before operating the air conditioner at every season Check if the remote control batteries needed to be replaced Ensure there is no obstructi...

Страница 8: ...orized Distributor under the following conditions Abnormal noise during operation Circuit breaker switches off frequently Water foreign particles have entered the Remote Control Power plug cord becomes unnaturally warm Water leak from Indoor unit Switches or buttons are not functioning properly NON SERVICEABLE CRITERIAS ...

Отзывы: