Operation Details

•  Unit selects the operation mode 

according to the room temperature.

•  Once the operation mode is 

selected, the unit will operate at 
the standard setting temperature 
as shown:

Room

temperature

Operation

mode

Standard 

setting 

temperature

23°C & 

above

Cool

25°C

Below

23°C

Dry

22°C

Below

20°C

Heat

21°C

• Press 

or 

to change the 

temperature setting to “HI” or “LO” 
as shown:

Operation mode

HI

LO

Cool

27°C

23°C

Dry

24°C

20°C

Heat

23°C

19°C

AUTO - Automatic Operation

AUTO, HEAT, COOL, DRY

Select the 
desired 
operation.

2

2

Start the 
operation.

1

1

 

Hint

•  A temperature setting 1°C higher 

in cooling operation or 2°C lower in 
heating operation than the desired 
temperature equates to a 10% 
power saving.

•  Enjoy cool air at your desired 

temperature.

•  The range of temperature can be 

selected from 16°C ~ 30°C.

COOL - Cooling Operation

•  Keep your environment 

dehumidi

fi

 ed by running cooling 

operation at a low fan speed.

•  The range of temperature can be 

selected from 16°C ~ 30°C.

DRY - Soft Dry Operation

•  In heating mode, it takes a while 

for the unit to warm up. The 
power indicator blinks during this 
operation.

•  The range of temperature can be 

selected from 16°C ~ 30°C.

HEAT - Heating Operation

Troubleshooting

  Mist emerges from indoor unit.

  Condensation effect due to cooling process.

  Heating/Cooling operation does not work.

  Ensure temperature is set correctly.

  Make sure windows and doors are closed.

 Make sure 

fi

 lters are cleaned and replaced.

  Make sure inlet and outlet vents are cleared.

 Water 

fl

 owing sound during operations.

 Cause by refrigerant 

fl

 ow inside the unit.

  The power indicator blinks during the operation and 

the indoor fan is stopped.

  The unit is in defrost mode, and the melted frost is drained from the 

outdoor unit.

AUTO 

FAN 

SPEED
AIR

SWING

HEAT 

OFF

OFF

TIMER

ON

TIMER

COOL 

DRY 

OFF/ON

TEMP 

MODE

AIR SWING 

FAN SPEED 

QUIET 

POWERFUL 

SET 

CLOCK

RESET 

TIMER

ON

1

2

3

OFF

SET 

CANCEL 

Set the
temperature.

3

3

  Supersonic air purifying device (super alleru-buster) operates 

automatically once the unit is switched on.

 

POWERFUL 

and 

QUIET

operations are available in all modes. 

 Press 

OFF/ON

 again to stop the operation.

Содержание CS-W12EKR

Страница 1: ...d keep them for future reference Manufactured by Panasonic HA Air Conditioning M Sdn Bhd Lot 2 Persiaran Tengku Ampuan Section 21 Shah Alam Industrial Site 40300 Shah Alam Selangor Malaysia 2006 Panasonic HA Air Conditioning M Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law QUIET POWERFUL TIMER POWER ...

Страница 2: ...oor unit Do not attempt to repair the unit by yourself Do not use rechargeable Ni Cd batteries Do not allow infants and small children to play with remote control to prevent them from accidentally swallowing the batteries Do not install remove and reinstall the unit by yourself improper installation will cause leakage electric shock or fire Please consult an authorized dealer or specialist for the...

Страница 3: ...tions for end user for air conditioners Information on Disposal in other countries outside the European Union This symbol is only valid in the European Union If you wish to discard this product please contact your installer dealer or local authority and ask for the correct method of disposal E Environmental Requirements nvironmental Requirements End of Life Disposal End of Life Disposal The applia...

Страница 4: ...gle beep sound is heard and release 2 Press again until a double beep sound is heard and release 3 Press to switch the sound on or off Long beep OFF short beep ON 1 Pull out the cover 2 Insert AAA or R03 batteries 5 Press to set time SET 2 CL ER 4 Press CLOCK Indoor Unit Indoor Unit Air intake Airflow direction louver Air filter Front panel Supersonic air purifying device Auto OFF ON button Discha...

Страница 5: ...ted from 16 C 30 C DRY Soft Dry Operation In heating mode it takes a while for the unit to warm up The power indicator blinks during this operation The range of temperature can be selected from 16 C 30 C HEAT Heating Operation Troubleshooting Mist emerges from indoor unit Condensation effect due to cooling process Heating Cooling operation does not work Ensure temperature is set correctly Make sur...

Страница 6: ...w direction has been set the louvers swing up and down automatically For HEATING operation the air blows horizontally for a while then starts to blow downwards Do not adjust the vertical airflow direction louver by hand Horizontal airflow direction louver is manually adjustable Select fan speed Adjust the airflow direction louver PEED Troubleshooting The room has a peculiar odour This may be a dam...

Страница 7: ... OFF OFF TIMER ON TIMER COOL DRY OFF ON TEMP MODE AIR SWING FAN SPEED QUIET POWERFUL SET CLOCK RESET TIMER ON 1 2 3 OFF SET CANCEL POWERFUL and QUIET operations could not be activated at the same time POWERFUL and QUIET operations could be cancelled by pressing the respective button again Troubleshooting Noisy during operation The unit may have been installed at an incline or the front panel is no...

Страница 8: ...he air conditioner on or off automatically The unit may start in preliminary operation before the actual set time when ON timer has been set The set timer repeats daily once set If there is a power failure you can restore the previous setting once power is resumed by pressing the button If the timer is cancelled press to restore the previous setting Set the desired time 2 2 P AIR S N SPE Confirm t...

Страница 9: ...reduce power consumption Please consult your nearest dealer for seasonal inspection SUPER ALLERU BUSTER It is recommended to clean this filter every 6 months Replace the filter every 3 years or replace any damaged filters Part no CZ SA13P Vacuum the super alleru buster filter Vacuum wash and dry the frame Remove For extended non use Activate heating for 2 3 hours to thoroughly dry the unit Turn of...

Страница 10: ...NDED NON USE Checking of remote control batteries No obstruction at inlet and outlet vents After 15 minutes of operation it is normal to have the following temperature difference between inlet and outlet vents Cooling 8 C Heating 14 C ...

Страница 11: ...wing conditions Abnormal noise during operation Circuit breaker switches off frequently Water foreign particles have entered the Remote Control Power cord becomes unnaturally warm Water leak from Indoor unit Switches or buttons are not functioning properly NON SERVICEABLE CRITERIAS ...

Страница 12: ...Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global F565374 Printed in Malaysia OPTH0604 00 ...

Отзывы: